Cargando…
Recommendations for the application and follow-up of quality controls in medical laboratories
This is a translation of the paper “Recommendations for the application and follow-up of quality controls in medical biology laboratories” published in French in the journal Annales de Biologie Clinique (Recommandations pour la mise en place et le suivi des contrôles de qualité dans les laboratoires...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Croatian Society of Medical Biochemistry and Laboratory Medicine
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8047787/ https://www.ncbi.nlm.nih.gov/pubmed/33927549 http://dx.doi.org/10.11613/BM.2021.020501 |
_version_ | 1783679110281691136 |
---|---|
author | Giannoli, Jean-Marc Albarede, Stéphanie Avellan, Thierry Bouilloux, Jean-Pierre Cartier, Régine Cohen, Richard Colard, Nathalie Essemilaire, Luc Galinier, Jean-Louis Kuentz, Mathieu Paris, Mickaël Portugal, Henri Scherrer, Florian Siest, Jean-Pascal Vassault, Anne Vialle, Jean-Michel |
author_facet | Giannoli, Jean-Marc Albarede, Stéphanie Avellan, Thierry Bouilloux, Jean-Pierre Cartier, Régine Cohen, Richard Colard, Nathalie Essemilaire, Luc Galinier, Jean-Louis Kuentz, Mathieu Paris, Mickaël Portugal, Henri Scherrer, Florian Siest, Jean-Pascal Vassault, Anne Vialle, Jean-Michel |
author_sort | Giannoli, Jean-Marc |
collection | PubMed |
description | This is a translation of the paper “Recommendations for the application and follow-up of quality controls in medical biology laboratories” published in French in the journal Annales de Biologie Clinique (Recommandations pour la mise en place et le suivi des contrôles de qualité dans les laboratoires de biologie médicale. Ann Biol Clin (Paris). 2019;77:577-97.). The recommendations proposed in this document are the result of work conducted jointly by the Network of Accredited Medical Laboratories (LABAC), the French Society of Medical Biology (SFBC) and the Federation of Associations for External Quality Assessment (FAEEQ). The different steps of the implementation of quality controls, based on a risk analysis, are described. The changes of reagent or internal quality control (IQC) materials batches, the action to be taken in case of non-conform IQC results, the choice of external quality assessment (EQA) scheme and interpretation of their results as well as the new issue of analyses performed on several automatic systems available in the same laboratory are discussed. Finally, the concept of measurement uncertainty, the robustness of the methods as well as the specificities of near-patient testing and rapid tests are described. These recommendations cannot apply for all cases we can find in medical laboratories. The implementation of an objective alternative strategy, supported with documented evidence, might be equally considered. |
format | Online Article Text |
id | pubmed-8047787 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Croatian Society of Medical Biochemistry and Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-80477872021-04-28 Recommendations for the application and follow-up of quality controls in medical laboratories Giannoli, Jean-Marc Albarede, Stéphanie Avellan, Thierry Bouilloux, Jean-Pierre Cartier, Régine Cohen, Richard Colard, Nathalie Essemilaire, Luc Galinier, Jean-Louis Kuentz, Mathieu Paris, Mickaël Portugal, Henri Scherrer, Florian Siest, Jean-Pascal Vassault, Anne Vialle, Jean-Michel Biochem Med (Zagreb) Translation This is a translation of the paper “Recommendations for the application and follow-up of quality controls in medical biology laboratories” published in French in the journal Annales de Biologie Clinique (Recommandations pour la mise en place et le suivi des contrôles de qualité dans les laboratoires de biologie médicale. Ann Biol Clin (Paris). 2019;77:577-97.). The recommendations proposed in this document are the result of work conducted jointly by the Network of Accredited Medical Laboratories (LABAC), the French Society of Medical Biology (SFBC) and the Federation of Associations for External Quality Assessment (FAEEQ). The different steps of the implementation of quality controls, based on a risk analysis, are described. The changes of reagent or internal quality control (IQC) materials batches, the action to be taken in case of non-conform IQC results, the choice of external quality assessment (EQA) scheme and interpretation of their results as well as the new issue of analyses performed on several automatic systems available in the same laboratory are discussed. Finally, the concept of measurement uncertainty, the robustness of the methods as well as the specificities of near-patient testing and rapid tests are described. These recommendations cannot apply for all cases we can find in medical laboratories. The implementation of an objective alternative strategy, supported with documented evidence, might be equally considered. Croatian Society of Medical Biochemistry and Laboratory Medicine 2021-04-15 2021-06-15 /pmc/articles/PMC8047787/ /pubmed/33927549 http://dx.doi.org/10.11613/BM.2021.020501 Text en Croatian Society of Medical Biochemistry and Laboratory Medicine. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Translation Giannoli, Jean-Marc Albarede, Stéphanie Avellan, Thierry Bouilloux, Jean-Pierre Cartier, Régine Cohen, Richard Colard, Nathalie Essemilaire, Luc Galinier, Jean-Louis Kuentz, Mathieu Paris, Mickaël Portugal, Henri Scherrer, Florian Siest, Jean-Pascal Vassault, Anne Vialle, Jean-Michel Recommendations for the application and follow-up of quality controls in medical laboratories |
title | Recommendations for the application and follow-up of quality controls in medical laboratories |
title_full | Recommendations for the application and follow-up of quality controls in medical laboratories |
title_fullStr | Recommendations for the application and follow-up of quality controls in medical laboratories |
title_full_unstemmed | Recommendations for the application and follow-up of quality controls in medical laboratories |
title_short | Recommendations for the application and follow-up of quality controls in medical laboratories |
title_sort | recommendations for the application and follow-up of quality controls in medical laboratories |
topic | Translation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8047787/ https://www.ncbi.nlm.nih.gov/pubmed/33927549 http://dx.doi.org/10.11613/BM.2021.020501 |
work_keys_str_mv | AT giannolijeanmarc recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT albaredestephanie recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT avellanthierry recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT bouillouxjeanpierre recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT cartierregine recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT cohenrichard recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT colardnathalie recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT essemilaireluc recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT galinierjeanlouis recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT kuentzmathieu recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT parismickael recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT portugalhenri recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT scherrerflorian recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT siestjeanpascal recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT vassaultanne recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories AT viallejeanmichel recommendationsfortheapplicationandfollowupofqualitycontrolsinmedicallaboratories |