Cargando…

Safety and chronic lesion characterization of pulsed field ablation in a Porcine model

BACKGROUND: Pulsed field ablation (PFA) has been identified as an alternative to thermal‐based ablation systems for treatment of atrial fibrillation patients. The objective of this Good Laboratory Practice (GLP) study was to characterize the chronic effects and safety of overlapping lesions created...

Descripción completa

Detalles Bibliográficos
Autores principales: Stewart, Mark T., Haines, David E., Miklavčič, Damijan, Kos, Bor, Kirchhof, Nicole, Barka, Noah, Mattison, Lars, Martien, Matt, Onal, Birce, Howard, Brian, Verma, Atul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8048690/
https://www.ncbi.nlm.nih.gov/pubmed/33650743
http://dx.doi.org/10.1111/jce.14980
_version_ 1783679278928363520
author Stewart, Mark T.
Haines, David E.
Miklavčič, Damijan
Kos, Bor
Kirchhof, Nicole
Barka, Noah
Mattison, Lars
Martien, Matt
Onal, Birce
Howard, Brian
Verma, Atul
author_facet Stewart, Mark T.
Haines, David E.
Miklavčič, Damijan
Kos, Bor
Kirchhof, Nicole
Barka, Noah
Mattison, Lars
Martien, Matt
Onal, Birce
Howard, Brian
Verma, Atul
author_sort Stewart, Mark T.
collection PubMed
description BACKGROUND: Pulsed field ablation (PFA) has been identified as an alternative to thermal‐based ablation systems for treatment of atrial fibrillation patients. The objective of this Good Laboratory Practice (GLP) study was to characterize the chronic effects and safety of overlapping lesions created by a PFA system at intracardiac locations in a porcine model. METHODS: A circular catheter with nine gold electrodes was used for overlapping low‐ or high‐dose PFA deliveries in the superior vena cava (SVC), right atrial appendage (RAA), and right superior pulmonary vein (RSPV) in six pigs. Electrical isolation was evaluated acutely and chronic lesions were assessed via necropsy and histopathology after 4‐week survival. Acute and chronic safety data were recorded peri‐ and post‐procedurally. RESULTS: No animal experienced ventricular arrhythmia during PFA delivery, and there was no evidence of periprocedural PFA‐related adverse events. Lesions created in all anatomies resulted in electrical isolation postprocedure. Lesions were circumferential, contiguous, and transmural, with all converting into consistent lines of chronic replacement fibrosis, regardless of trabeculated or smooth endocardial surface structure. Ablations were non‐thermally generated with only minimal post‐delivery temperature rises recorded at the electrodes. There was no evidence of extracardiac damage, stenosis, aneurysms, endocardial disruption, or thrombus. CONCLUSION: PFA deliveries to the SVC, RAA, and RSPV resulted in complete circumferential replacement fibrosis at 4‐week postablation with an excellent chronic myocardial and collateral tissue safety profile. This GLP study evaluated the safety and efficacy of a dosage range in preparation for a clinical trial and characterized the non‐thermal nature of PFA.
format Online
Article
Text
id pubmed-8048690
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-80486902021-04-19 Safety and chronic lesion characterization of pulsed field ablation in a Porcine model Stewart, Mark T. Haines, David E. Miklavčič, Damijan Kos, Bor Kirchhof, Nicole Barka, Noah Mattison, Lars Martien, Matt Onal, Birce Howard, Brian Verma, Atul J Cardiovasc Electrophysiol Original Articles BACKGROUND: Pulsed field ablation (PFA) has been identified as an alternative to thermal‐based ablation systems for treatment of atrial fibrillation patients. The objective of this Good Laboratory Practice (GLP) study was to characterize the chronic effects and safety of overlapping lesions created by a PFA system at intracardiac locations in a porcine model. METHODS: A circular catheter with nine gold electrodes was used for overlapping low‐ or high‐dose PFA deliveries in the superior vena cava (SVC), right atrial appendage (RAA), and right superior pulmonary vein (RSPV) in six pigs. Electrical isolation was evaluated acutely and chronic lesions were assessed via necropsy and histopathology after 4‐week survival. Acute and chronic safety data were recorded peri‐ and post‐procedurally. RESULTS: No animal experienced ventricular arrhythmia during PFA delivery, and there was no evidence of periprocedural PFA‐related adverse events. Lesions created in all anatomies resulted in electrical isolation postprocedure. Lesions were circumferential, contiguous, and transmural, with all converting into consistent lines of chronic replacement fibrosis, regardless of trabeculated or smooth endocardial surface structure. Ablations were non‐thermally generated with only minimal post‐delivery temperature rises recorded at the electrodes. There was no evidence of extracardiac damage, stenosis, aneurysms, endocardial disruption, or thrombus. CONCLUSION: PFA deliveries to the SVC, RAA, and RSPV resulted in complete circumferential replacement fibrosis at 4‐week postablation with an excellent chronic myocardial and collateral tissue safety profile. This GLP study evaluated the safety and efficacy of a dosage range in preparation for a clinical trial and characterized the non‐thermal nature of PFA. John Wiley and Sons Inc. 2021-03-10 2021-04 /pmc/articles/PMC8048690/ /pubmed/33650743 http://dx.doi.org/10.1111/jce.14980 Text en © 2021 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals LLC https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Stewart, Mark T.
Haines, David E.
Miklavčič, Damijan
Kos, Bor
Kirchhof, Nicole
Barka, Noah
Mattison, Lars
Martien, Matt
Onal, Birce
Howard, Brian
Verma, Atul
Safety and chronic lesion characterization of pulsed field ablation in a Porcine model
title Safety and chronic lesion characterization of pulsed field ablation in a Porcine model
title_full Safety and chronic lesion characterization of pulsed field ablation in a Porcine model
title_fullStr Safety and chronic lesion characterization of pulsed field ablation in a Porcine model
title_full_unstemmed Safety and chronic lesion characterization of pulsed field ablation in a Porcine model
title_short Safety and chronic lesion characterization of pulsed field ablation in a Porcine model
title_sort safety and chronic lesion characterization of pulsed field ablation in a porcine model
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8048690/
https://www.ncbi.nlm.nih.gov/pubmed/33650743
http://dx.doi.org/10.1111/jce.14980
work_keys_str_mv AT stewartmarkt safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel
AT hainesdavide safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel
AT miklavcicdamijan safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel
AT kosbor safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel
AT kirchhofnicole safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel
AT barkanoah safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel
AT mattisonlars safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel
AT martienmatt safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel
AT onalbirce safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel
AT howardbrian safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel
AT vermaatul safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel