Cargando…
Safety and chronic lesion characterization of pulsed field ablation in a Porcine model
BACKGROUND: Pulsed field ablation (PFA) has been identified as an alternative to thermal‐based ablation systems for treatment of atrial fibrillation patients. The objective of this Good Laboratory Practice (GLP) study was to characterize the chronic effects and safety of overlapping lesions created...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8048690/ https://www.ncbi.nlm.nih.gov/pubmed/33650743 http://dx.doi.org/10.1111/jce.14980 |
_version_ | 1783679278928363520 |
---|---|
author | Stewart, Mark T. Haines, David E. Miklavčič, Damijan Kos, Bor Kirchhof, Nicole Barka, Noah Mattison, Lars Martien, Matt Onal, Birce Howard, Brian Verma, Atul |
author_facet | Stewart, Mark T. Haines, David E. Miklavčič, Damijan Kos, Bor Kirchhof, Nicole Barka, Noah Mattison, Lars Martien, Matt Onal, Birce Howard, Brian Verma, Atul |
author_sort | Stewart, Mark T. |
collection | PubMed |
description | BACKGROUND: Pulsed field ablation (PFA) has been identified as an alternative to thermal‐based ablation systems for treatment of atrial fibrillation patients. The objective of this Good Laboratory Practice (GLP) study was to characterize the chronic effects and safety of overlapping lesions created by a PFA system at intracardiac locations in a porcine model. METHODS: A circular catheter with nine gold electrodes was used for overlapping low‐ or high‐dose PFA deliveries in the superior vena cava (SVC), right atrial appendage (RAA), and right superior pulmonary vein (RSPV) in six pigs. Electrical isolation was evaluated acutely and chronic lesions were assessed via necropsy and histopathology after 4‐week survival. Acute and chronic safety data were recorded peri‐ and post‐procedurally. RESULTS: No animal experienced ventricular arrhythmia during PFA delivery, and there was no evidence of periprocedural PFA‐related adverse events. Lesions created in all anatomies resulted in electrical isolation postprocedure. Lesions were circumferential, contiguous, and transmural, with all converting into consistent lines of chronic replacement fibrosis, regardless of trabeculated or smooth endocardial surface structure. Ablations were non‐thermally generated with only minimal post‐delivery temperature rises recorded at the electrodes. There was no evidence of extracardiac damage, stenosis, aneurysms, endocardial disruption, or thrombus. CONCLUSION: PFA deliveries to the SVC, RAA, and RSPV resulted in complete circumferential replacement fibrosis at 4‐week postablation with an excellent chronic myocardial and collateral tissue safety profile. This GLP study evaluated the safety and efficacy of a dosage range in preparation for a clinical trial and characterized the non‐thermal nature of PFA. |
format | Online Article Text |
id | pubmed-8048690 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-80486902021-04-19 Safety and chronic lesion characterization of pulsed field ablation in a Porcine model Stewart, Mark T. Haines, David E. Miklavčič, Damijan Kos, Bor Kirchhof, Nicole Barka, Noah Mattison, Lars Martien, Matt Onal, Birce Howard, Brian Verma, Atul J Cardiovasc Electrophysiol Original Articles BACKGROUND: Pulsed field ablation (PFA) has been identified as an alternative to thermal‐based ablation systems for treatment of atrial fibrillation patients. The objective of this Good Laboratory Practice (GLP) study was to characterize the chronic effects and safety of overlapping lesions created by a PFA system at intracardiac locations in a porcine model. METHODS: A circular catheter with nine gold electrodes was used for overlapping low‐ or high‐dose PFA deliveries in the superior vena cava (SVC), right atrial appendage (RAA), and right superior pulmonary vein (RSPV) in six pigs. Electrical isolation was evaluated acutely and chronic lesions were assessed via necropsy and histopathology after 4‐week survival. Acute and chronic safety data were recorded peri‐ and post‐procedurally. RESULTS: No animal experienced ventricular arrhythmia during PFA delivery, and there was no evidence of periprocedural PFA‐related adverse events. Lesions created in all anatomies resulted in electrical isolation postprocedure. Lesions were circumferential, contiguous, and transmural, with all converting into consistent lines of chronic replacement fibrosis, regardless of trabeculated or smooth endocardial surface structure. Ablations were non‐thermally generated with only minimal post‐delivery temperature rises recorded at the electrodes. There was no evidence of extracardiac damage, stenosis, aneurysms, endocardial disruption, or thrombus. CONCLUSION: PFA deliveries to the SVC, RAA, and RSPV resulted in complete circumferential replacement fibrosis at 4‐week postablation with an excellent chronic myocardial and collateral tissue safety profile. This GLP study evaluated the safety and efficacy of a dosage range in preparation for a clinical trial and characterized the non‐thermal nature of PFA. John Wiley and Sons Inc. 2021-03-10 2021-04 /pmc/articles/PMC8048690/ /pubmed/33650743 http://dx.doi.org/10.1111/jce.14980 Text en © 2021 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals LLC https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Original Articles Stewart, Mark T. Haines, David E. Miklavčič, Damijan Kos, Bor Kirchhof, Nicole Barka, Noah Mattison, Lars Martien, Matt Onal, Birce Howard, Brian Verma, Atul Safety and chronic lesion characterization of pulsed field ablation in a Porcine model |
title | Safety and chronic lesion characterization of pulsed field ablation in a Porcine model |
title_full | Safety and chronic lesion characterization of pulsed field ablation in a Porcine model |
title_fullStr | Safety and chronic lesion characterization of pulsed field ablation in a Porcine model |
title_full_unstemmed | Safety and chronic lesion characterization of pulsed field ablation in a Porcine model |
title_short | Safety and chronic lesion characterization of pulsed field ablation in a Porcine model |
title_sort | safety and chronic lesion characterization of pulsed field ablation in a porcine model |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8048690/ https://www.ncbi.nlm.nih.gov/pubmed/33650743 http://dx.doi.org/10.1111/jce.14980 |
work_keys_str_mv | AT stewartmarkt safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel AT hainesdavide safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel AT miklavcicdamijan safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel AT kosbor safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel AT kirchhofnicole safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel AT barkanoah safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel AT mattisonlars safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel AT martienmatt safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel AT onalbirce safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel AT howardbrian safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel AT vermaatul safetyandchroniclesioncharacterizationofpulsedfieldablationinaporcinemodel |