Exploring label dynamics of velocity‐selective arterial spin labeling in the kidney

PURPOSE: Velocity‐selective arterial spin labeling (VSASL) has been proposed for renal perfusion imaging to mitigate planning challenges and effects of arterial transit time (ATT) uncertainties. In VSASL, label generation may shift in the vascular tree as a function of cutoff velocity. Here, we inve...

Descripción completa

Detalles Bibliográficos
Autores principales: Bones, Isabell K., Franklin, Suzanne L., Harteveld, Anita A., van Osch, Matthias J. P., Schmid, Sophie, Hendrikse, Jeroen, Moonen, Chrit, van Stralen, Marijn, Bos, Clemens
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8048977/
https://www.ncbi.nlm.nih.gov/pubmed/33538350
http://dx.doi.org/10.1002/mrm.28683
_version_ 1783679338613309440
author Bones, Isabell K.
Franklin, Suzanne L.
Harteveld, Anita A.
van Osch, Matthias J. P.
Schmid, Sophie
Hendrikse, Jeroen
Moonen, Chrit
van Stralen, Marijn
Bos, Clemens
author_facet Bones, Isabell K.
Franklin, Suzanne L.
Harteveld, Anita A.
van Osch, Matthias J. P.
Schmid, Sophie
Hendrikse, Jeroen
Moonen, Chrit
van Stralen, Marijn
Bos, Clemens
author_sort Bones, Isabell K.
collection PubMed
description PURPOSE: Velocity‐selective arterial spin labeling (VSASL) has been proposed for renal perfusion imaging to mitigate planning challenges and effects of arterial transit time (ATT) uncertainties. In VSASL, label generation may shift in the vascular tree as a function of cutoff velocity. Here, we investigate label dynamics and especially the ATT of renal VSASL and compared it with a spatially selective pulsed arterial spin labeling technique, flow alternating inversion recovery (FAIR). METHODS: Arterial spin labeling data were acquired in 7 subjects, using free‐breathing dual VSASL and FAIR with five postlabeling delays: 400, 800, 1200, 2000, and 2600 ms. The VSASL measurements were acquired with cutoff velocities of 5, 10, and 15 cm/s, with anterior–posterior velocity‐encoding direction. Cortical perfusion‐weighted signal, temporal SNR, quantified renal blood flow, and arterial transit time were reported. RESULTS: In contrast to FAIR, renal VSASL already showed fairly high signal at the earliest postlabeling delays, for all cutoff velocities. The highest VSASL signal and temporal SNR was obtained with a cutoff velocity of 10 cm/s at postlabeling delay = 800 ms, which was earlier than for FAIR at 1200 ms. Fitted ATT on VSASL was ≤ 0 ms, indicating ATT insensitivity, which was shorter than for FAIR (189 ± 79 ms, P < .05). Finally, the average cortical renal blood flow measured with cutoff velocities of 5 cm/s (398 ± 84 mL/min/100 g) and 10 cm/s (472 ± 160 mL/min/100 g) were similar to renal blood flow measured with FAIR (441 ± 84 mL/min/100 g) (P > .05) with good correlations on subject level. CONCLUSION: Velocity‐selective arterial spin labeling in the kidney reduces ATT sensitivity compared with the recommended pulsed arterial spin labeling method, as well as if cutoff velocity is increased to reduce spurious labeling due to motion. Thus, VSASL has potential as a method for time‐efficient, single‐time‐point, free‐breathing renal perfusion measurements, despite lower tSNR than FAIR.
format Online
Article
Text
id pubmed-8048977
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-80489772021-04-20 Exploring label dynamics of velocity‐selective arterial spin labeling in the kidney Bones, Isabell K. Franklin, Suzanne L. Harteveld, Anita A. van Osch, Matthias J. P. Schmid, Sophie Hendrikse, Jeroen Moonen, Chrit van Stralen, Marijn Bos, Clemens Magn Reson Med Full Papers—Imaging Methodology PURPOSE: Velocity‐selective arterial spin labeling (VSASL) has been proposed for renal perfusion imaging to mitigate planning challenges and effects of arterial transit time (ATT) uncertainties. In VSASL, label generation may shift in the vascular tree as a function of cutoff velocity. Here, we investigate label dynamics and especially the ATT of renal VSASL and compared it with a spatially selective pulsed arterial spin labeling technique, flow alternating inversion recovery (FAIR). METHODS: Arterial spin labeling data were acquired in 7 subjects, using free‐breathing dual VSASL and FAIR with five postlabeling delays: 400, 800, 1200, 2000, and 2600 ms. The VSASL measurements were acquired with cutoff velocities of 5, 10, and 15 cm/s, with anterior–posterior velocity‐encoding direction. Cortical perfusion‐weighted signal, temporal SNR, quantified renal blood flow, and arterial transit time were reported. RESULTS: In contrast to FAIR, renal VSASL already showed fairly high signal at the earliest postlabeling delays, for all cutoff velocities. The highest VSASL signal and temporal SNR was obtained with a cutoff velocity of 10 cm/s at postlabeling delay = 800 ms, which was earlier than for FAIR at 1200 ms. Fitted ATT on VSASL was ≤ 0 ms, indicating ATT insensitivity, which was shorter than for FAIR (189 ± 79 ms, P < .05). Finally, the average cortical renal blood flow measured with cutoff velocities of 5 cm/s (398 ± 84 mL/min/100 g) and 10 cm/s (472 ± 160 mL/min/100 g) were similar to renal blood flow measured with FAIR (441 ± 84 mL/min/100 g) (P > .05) with good correlations on subject level. CONCLUSION: Velocity‐selective arterial spin labeling in the kidney reduces ATT sensitivity compared with the recommended pulsed arterial spin labeling method, as well as if cutoff velocity is increased to reduce spurious labeling due to motion. Thus, VSASL has potential as a method for time‐efficient, single‐time‐point, free‐breathing renal perfusion measurements, despite lower tSNR than FAIR. John Wiley and Sons Inc. 2021-02-04 2021-07 /pmc/articles/PMC8048977/ /pubmed/33538350 http://dx.doi.org/10.1002/mrm.28683 Text en © 2021 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Full Papers—Imaging Methodology
Bones, Isabell K.
Franklin, Suzanne L.
Harteveld, Anita A.
van Osch, Matthias J. P.
Schmid, Sophie
Hendrikse, Jeroen
Moonen, Chrit
van Stralen, Marijn
Bos, Clemens
Exploring label dynamics of velocity‐selective arterial spin labeling in the kidney
title Exploring label dynamics of velocity‐selective arterial spin labeling in the kidney
title_full Exploring label dynamics of velocity‐selective arterial spin labeling in the kidney
title_fullStr Exploring label dynamics of velocity‐selective arterial spin labeling in the kidney
title_full_unstemmed Exploring label dynamics of velocity‐selective arterial spin labeling in the kidney
title_short Exploring label dynamics of velocity‐selective arterial spin labeling in the kidney
title_sort exploring label dynamics of velocity‐selective arterial spin labeling in the kidney
topic Full Papers—Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8048977/
https://www.ncbi.nlm.nih.gov/pubmed/33538350
http://dx.doi.org/10.1002/mrm.28683
work_keys_str_mv AT bonesisabellk exploringlabeldynamicsofvelocityselectivearterialspinlabelinginthekidney
AT franklinsuzannel exploringlabeldynamicsofvelocityselectivearterialspinlabelinginthekidney
AT harteveldanitaa exploringlabeldynamicsofvelocityselectivearterialspinlabelinginthekidney
AT vanoschmatthiasjp exploringlabeldynamicsofvelocityselectivearterialspinlabelinginthekidney
AT schmidsophie exploringlabeldynamicsofvelocityselectivearterialspinlabelinginthekidney
AT hendriksejeroen exploringlabeldynamicsofvelocityselectivearterialspinlabelinginthekidney
AT moonenchrit exploringlabeldynamicsofvelocityselectivearterialspinlabelinginthekidney
AT vanstralenmarijn exploringlabeldynamicsofvelocityselectivearterialspinlabelinginthekidney
AT bosclemens exploringlabeldynamicsofvelocityselectivearterialspinlabelinginthekidney