Cargando…

Impact of physiologically shaped pancreatic stent for chronic pancreatitis

Endoscopic pancreatic stenting is used to prevent main pancreatic duct obstruction and relieve painful symptoms of chronic pancreatitis. However, the stent typically needs to be exchanged and the rate of adverse events is high. Few studies have evaluated the effect of stent shape on those outcomes....

Descripción completa

Detalles Bibliográficos
Autores principales: Hori, Yasuki, Ichino, Yuka, Naitoh, Itaru, Hayashi, Kazuki, Yoshida, Michihiro, Natsume, Makoto, Jinno, Naruomi, Kato, Akihisa, Kachi, Kenta, Asano, Go, Atsuta, Naoki, Sahashi, Hidenori, Kataoka, Hiromi, Ohara, Hirotaka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8050315/
https://www.ncbi.nlm.nih.gov/pubmed/33859301
http://dx.doi.org/10.1038/s41598-021-87852-1
_version_ 1783679575740383232
author Hori, Yasuki
Ichino, Yuka
Naitoh, Itaru
Hayashi, Kazuki
Yoshida, Michihiro
Natsume, Makoto
Jinno, Naruomi
Kato, Akihisa
Kachi, Kenta
Asano, Go
Atsuta, Naoki
Sahashi, Hidenori
Kataoka, Hiromi
Ohara, Hirotaka
author_facet Hori, Yasuki
Ichino, Yuka
Naitoh, Itaru
Hayashi, Kazuki
Yoshida, Michihiro
Natsume, Makoto
Jinno, Naruomi
Kato, Akihisa
Kachi, Kenta
Asano, Go
Atsuta, Naoki
Sahashi, Hidenori
Kataoka, Hiromi
Ohara, Hirotaka
author_sort Hori, Yasuki
collection PubMed
description Endoscopic pancreatic stenting is used to prevent main pancreatic duct obstruction and relieve painful symptoms of chronic pancreatitis. However, the stent typically needs to be exchanged and the rate of adverse events is high. Few studies have evaluated the effect of stent shape on those outcomes. We evaluated the adverse events, stent patency, and total medical cost within 90 days of patients who received an 8.5 French (Fr) physiologically shaped pancreatic stent by comparing these features with those associated with a conventional straight-type stent for ≥ 90 days. The total stent-related adverse event rate was significantly lower for the physiologically shaped pancreatic stent (physiologically shaped, 6.7% [2/30]; straight-type, 50.6% [44/87]; P < 0.001). Stent occlusion was significantly less frequent (P < 0.001) and the total medical costs were significantly lower (P = 0.002) for the physiologically shaped stent. The stent-related adverse event rate was significantly higher for the 10 Fr straight type stent than for the 8.5 Fr physiologically shaped stent (10 Fr, straight-type vs. 8.5 Fr, physiologically shaped: 36.1% [13/36] vs. 6.7% [2/30]; P = 0.007). In conclusion, a physiologically shaped pancreatic stent was superior to a straight-type stent in terms of the patency rate and medical costs.
format Online
Article
Text
id pubmed-8050315
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-80503152021-04-16 Impact of physiologically shaped pancreatic stent for chronic pancreatitis Hori, Yasuki Ichino, Yuka Naitoh, Itaru Hayashi, Kazuki Yoshida, Michihiro Natsume, Makoto Jinno, Naruomi Kato, Akihisa Kachi, Kenta Asano, Go Atsuta, Naoki Sahashi, Hidenori Kataoka, Hiromi Ohara, Hirotaka Sci Rep Article Endoscopic pancreatic stenting is used to prevent main pancreatic duct obstruction and relieve painful symptoms of chronic pancreatitis. However, the stent typically needs to be exchanged and the rate of adverse events is high. Few studies have evaluated the effect of stent shape on those outcomes. We evaluated the adverse events, stent patency, and total medical cost within 90 days of patients who received an 8.5 French (Fr) physiologically shaped pancreatic stent by comparing these features with those associated with a conventional straight-type stent for ≥ 90 days. The total stent-related adverse event rate was significantly lower for the physiologically shaped pancreatic stent (physiologically shaped, 6.7% [2/30]; straight-type, 50.6% [44/87]; P < 0.001). Stent occlusion was significantly less frequent (P < 0.001) and the total medical costs were significantly lower (P = 0.002) for the physiologically shaped stent. The stent-related adverse event rate was significantly higher for the 10 Fr straight type stent than for the 8.5 Fr physiologically shaped stent (10 Fr, straight-type vs. 8.5 Fr, physiologically shaped: 36.1% [13/36] vs. 6.7% [2/30]; P = 0.007). In conclusion, a physiologically shaped pancreatic stent was superior to a straight-type stent in terms of the patency rate and medical costs. Nature Publishing Group UK 2021-04-15 /pmc/articles/PMC8050315/ /pubmed/33859301 http://dx.doi.org/10.1038/s41598-021-87852-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Hori, Yasuki
Ichino, Yuka
Naitoh, Itaru
Hayashi, Kazuki
Yoshida, Michihiro
Natsume, Makoto
Jinno, Naruomi
Kato, Akihisa
Kachi, Kenta
Asano, Go
Atsuta, Naoki
Sahashi, Hidenori
Kataoka, Hiromi
Ohara, Hirotaka
Impact of physiologically shaped pancreatic stent for chronic pancreatitis
title Impact of physiologically shaped pancreatic stent for chronic pancreatitis
title_full Impact of physiologically shaped pancreatic stent for chronic pancreatitis
title_fullStr Impact of physiologically shaped pancreatic stent for chronic pancreatitis
title_full_unstemmed Impact of physiologically shaped pancreatic stent for chronic pancreatitis
title_short Impact of physiologically shaped pancreatic stent for chronic pancreatitis
title_sort impact of physiologically shaped pancreatic stent for chronic pancreatitis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8050315/
https://www.ncbi.nlm.nih.gov/pubmed/33859301
http://dx.doi.org/10.1038/s41598-021-87852-1
work_keys_str_mv AT horiyasuki impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis
AT ichinoyuka impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis
AT naitohitaru impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis
AT hayashikazuki impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis
AT yoshidamichihiro impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis
AT natsumemakoto impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis
AT jinnonaruomi impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis
AT katoakihisa impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis
AT kachikenta impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis
AT asanogo impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis
AT atsutanaoki impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis
AT sahashihidenori impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis
AT kataokahiromi impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis
AT oharahirotaka impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis