Cargando…
Impact of physiologically shaped pancreatic stent for chronic pancreatitis
Endoscopic pancreatic stenting is used to prevent main pancreatic duct obstruction and relieve painful symptoms of chronic pancreatitis. However, the stent typically needs to be exchanged and the rate of adverse events is high. Few studies have evaluated the effect of stent shape on those outcomes....
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8050315/ https://www.ncbi.nlm.nih.gov/pubmed/33859301 http://dx.doi.org/10.1038/s41598-021-87852-1 |
_version_ | 1783679575740383232 |
---|---|
author | Hori, Yasuki Ichino, Yuka Naitoh, Itaru Hayashi, Kazuki Yoshida, Michihiro Natsume, Makoto Jinno, Naruomi Kato, Akihisa Kachi, Kenta Asano, Go Atsuta, Naoki Sahashi, Hidenori Kataoka, Hiromi Ohara, Hirotaka |
author_facet | Hori, Yasuki Ichino, Yuka Naitoh, Itaru Hayashi, Kazuki Yoshida, Michihiro Natsume, Makoto Jinno, Naruomi Kato, Akihisa Kachi, Kenta Asano, Go Atsuta, Naoki Sahashi, Hidenori Kataoka, Hiromi Ohara, Hirotaka |
author_sort | Hori, Yasuki |
collection | PubMed |
description | Endoscopic pancreatic stenting is used to prevent main pancreatic duct obstruction and relieve painful symptoms of chronic pancreatitis. However, the stent typically needs to be exchanged and the rate of adverse events is high. Few studies have evaluated the effect of stent shape on those outcomes. We evaluated the adverse events, stent patency, and total medical cost within 90 days of patients who received an 8.5 French (Fr) physiologically shaped pancreatic stent by comparing these features with those associated with a conventional straight-type stent for ≥ 90 days. The total stent-related adverse event rate was significantly lower for the physiologically shaped pancreatic stent (physiologically shaped, 6.7% [2/30]; straight-type, 50.6% [44/87]; P < 0.001). Stent occlusion was significantly less frequent (P < 0.001) and the total medical costs were significantly lower (P = 0.002) for the physiologically shaped stent. The stent-related adverse event rate was significantly higher for the 10 Fr straight type stent than for the 8.5 Fr physiologically shaped stent (10 Fr, straight-type vs. 8.5 Fr, physiologically shaped: 36.1% [13/36] vs. 6.7% [2/30]; P = 0.007). In conclusion, a physiologically shaped pancreatic stent was superior to a straight-type stent in terms of the patency rate and medical costs. |
format | Online Article Text |
id | pubmed-8050315 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-80503152021-04-16 Impact of physiologically shaped pancreatic stent for chronic pancreatitis Hori, Yasuki Ichino, Yuka Naitoh, Itaru Hayashi, Kazuki Yoshida, Michihiro Natsume, Makoto Jinno, Naruomi Kato, Akihisa Kachi, Kenta Asano, Go Atsuta, Naoki Sahashi, Hidenori Kataoka, Hiromi Ohara, Hirotaka Sci Rep Article Endoscopic pancreatic stenting is used to prevent main pancreatic duct obstruction and relieve painful symptoms of chronic pancreatitis. However, the stent typically needs to be exchanged and the rate of adverse events is high. Few studies have evaluated the effect of stent shape on those outcomes. We evaluated the adverse events, stent patency, and total medical cost within 90 days of patients who received an 8.5 French (Fr) physiologically shaped pancreatic stent by comparing these features with those associated with a conventional straight-type stent for ≥ 90 days. The total stent-related adverse event rate was significantly lower for the physiologically shaped pancreatic stent (physiologically shaped, 6.7% [2/30]; straight-type, 50.6% [44/87]; P < 0.001). Stent occlusion was significantly less frequent (P < 0.001) and the total medical costs were significantly lower (P = 0.002) for the physiologically shaped stent. The stent-related adverse event rate was significantly higher for the 10 Fr straight type stent than for the 8.5 Fr physiologically shaped stent (10 Fr, straight-type vs. 8.5 Fr, physiologically shaped: 36.1% [13/36] vs. 6.7% [2/30]; P = 0.007). In conclusion, a physiologically shaped pancreatic stent was superior to a straight-type stent in terms of the patency rate and medical costs. Nature Publishing Group UK 2021-04-15 /pmc/articles/PMC8050315/ /pubmed/33859301 http://dx.doi.org/10.1038/s41598-021-87852-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Hori, Yasuki Ichino, Yuka Naitoh, Itaru Hayashi, Kazuki Yoshida, Michihiro Natsume, Makoto Jinno, Naruomi Kato, Akihisa Kachi, Kenta Asano, Go Atsuta, Naoki Sahashi, Hidenori Kataoka, Hiromi Ohara, Hirotaka Impact of physiologically shaped pancreatic stent for chronic pancreatitis |
title | Impact of physiologically shaped pancreatic stent for chronic pancreatitis |
title_full | Impact of physiologically shaped pancreatic stent for chronic pancreatitis |
title_fullStr | Impact of physiologically shaped pancreatic stent for chronic pancreatitis |
title_full_unstemmed | Impact of physiologically shaped pancreatic stent for chronic pancreatitis |
title_short | Impact of physiologically shaped pancreatic stent for chronic pancreatitis |
title_sort | impact of physiologically shaped pancreatic stent for chronic pancreatitis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8050315/ https://www.ncbi.nlm.nih.gov/pubmed/33859301 http://dx.doi.org/10.1038/s41598-021-87852-1 |
work_keys_str_mv | AT horiyasuki impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis AT ichinoyuka impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis AT naitohitaru impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis AT hayashikazuki impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis AT yoshidamichihiro impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis AT natsumemakoto impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis AT jinnonaruomi impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis AT katoakihisa impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis AT kachikenta impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis AT asanogo impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis AT atsutanaoki impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis AT sahashihidenori impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis AT kataokahiromi impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis AT oharahirotaka impactofphysiologicallyshapedpancreaticstentforchronicpancreatitis |