Cargando…

Development and performance characteristics evaluation of a new Bioelectric Recognition Assay (BERA) method for rapid Sars-CoV-2 detection in clinical samples

INTRODUCTION: As the second wave of COVID-19 pandemic is in progress the development of fast and cost-effective approaches for diagnosis is essential. The aim of the present study was to develop and evaluate the performance characteristics of a new Bioelectric Recognition Assay (BERA) regarding Sars...

Descripción completa

Detalles Bibliográficos
Autores principales: Apostolou, Theofylaktos, Kyritsi, Maria, Vontas, Alexandros, Loizou, Konstantinos, Hadjilouka, Agni, Speletas, Mathaios, Mouchtouri, Varvara, Hadjichristodoulou, Christos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8051012/
https://www.ncbi.nlm.nih.gov/pubmed/33872651
http://dx.doi.org/10.1016/j.jviromet.2021.114166
Descripción
Sumario:INTRODUCTION: As the second wave of COVID-19 pandemic is in progress the development of fast and cost-effective approaches for diagnosis is essential. The aim of the present study was to develop and evaluate the performance characteristics of a new Bioelectric Recognition Assay (BERA) regarding Sars-CoV-2 detection in clinical samples and its potential to be used as a point of care test. MATERIALS AND METHODS: All tests were performed using a custom portable hardware device developed by EMBIO DIAGNOSTICS (EMBIO DIAGNOSTICS Ltd, Cyprus). 110 positive and 136 negative samples tested by RT-PCR were used in order to define the lower limit of detection (L.O.D.) of the system, as well as the sensitivity and the specificity of the method. RESULTS: The system was able to detect a viral concentration of 4 genome copies/μL. The method displayed total sensitivity of 92.7 % (95 %CI: 86.2–96.8) and 97.8 % specificity (95 %CI: 93.7–99.5). When samples were grouped according to the recorded Ct values the BERA biosensor displayed 100.00 % sensitivity (95 %CI: 84.6–100.0) for Ct values <20−30. For the aforementioned Ct values the Positive Predictive Value (PPV) of the method was estimated at 31.4 % for COVID-19 prevalence of 1% and at 70.5 % for 5% prevalence. At the same time the Negative Predictive Value (NPV) of the BERA biosensor was at 100.0 % for both prevalence rates. CONCLUSIONS: EMBIO DIAGNOSTICS BERA for the detection of SARS-CoV-2 infection has the potential to allow rapid and cost-effective detection and subsequent isolation of confirmed cases, and therefore reduce household and community transmissions.