Cargando…

Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy

Dental implants have been in vogue for more than three decades as a successful mode of rehabilitation of lost dentition. With time, there have been updates in methods and science including a positive tilt toward incorporation of digital technology into treatment protocols. This report elucidates a r...

Descripción completa

Detalles Bibliográficos
Autor principal: Gandhi, Yazad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8051656/
https://www.ncbi.nlm.nih.gov/pubmed/33897200
http://dx.doi.org/10.4103/njms.NJMS_51_20
_version_ 1783679774730747904
author Gandhi, Yazad
author_facet Gandhi, Yazad
author_sort Gandhi, Yazad
collection PubMed
description Dental implants have been in vogue for more than three decades as a successful mode of rehabilitation of lost dentition. With time, there have been updates in methods and science including a positive tilt toward incorporation of digital technology into treatment protocols. This report elucidates a rare case of faulty osteotomy preparation through a computer-aided design computer-aided manufacturing stent that was detected and corrected before implant placement. The manuscript also emphasizes the possible shrinkage of soft-tissue graft beyond the normal postulated time frame and the importance of periodical checks on the drilling protocol throughout the flapless placement procedure even though it may have been seamlessly planned on the digital platform.
format Online
Article
Text
id pubmed-8051656
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-80516562021-04-23 Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy Gandhi, Yazad Natl J Maxillofac Surg Case Report Dental implants have been in vogue for more than three decades as a successful mode of rehabilitation of lost dentition. With time, there have been updates in methods and science including a positive tilt toward incorporation of digital technology into treatment protocols. This report elucidates a rare case of faulty osteotomy preparation through a computer-aided design computer-aided manufacturing stent that was detected and corrected before implant placement. The manuscript also emphasizes the possible shrinkage of soft-tissue graft beyond the normal postulated time frame and the importance of periodical checks on the drilling protocol throughout the flapless placement procedure even though it may have been seamlessly planned on the digital platform. Wolters Kluwer - Medknow 2020 2020-12-16 /pmc/articles/PMC8051656/ /pubmed/33897200 http://dx.doi.org/10.4103/njms.NJMS_51_20 Text en Copyright: © 2020 National Journal of Maxillofacial Surgery https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Case Report
Gandhi, Yazad
Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy
title Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy
title_full Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy
title_fullStr Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy
title_full_unstemmed Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy
title_short Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy
title_sort dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8051656/
https://www.ncbi.nlm.nih.gov/pubmed/33897200
http://dx.doi.org/10.4103/njms.NJMS_51_20
work_keys_str_mv AT gandhiyazad dimensionalchangesinsofttissueasaplausiblecauseforerrorincomputeraideddesignandcomputeraidedmanufacturingstentguidedimplantosteotomy