Cargando…
Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy
Dental implants have been in vogue for more than three decades as a successful mode of rehabilitation of lost dentition. With time, there have been updates in methods and science including a positive tilt toward incorporation of digital technology into treatment protocols. This report elucidates a r...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8051656/ https://www.ncbi.nlm.nih.gov/pubmed/33897200 http://dx.doi.org/10.4103/njms.NJMS_51_20 |
_version_ | 1783679774730747904 |
---|---|
author | Gandhi, Yazad |
author_facet | Gandhi, Yazad |
author_sort | Gandhi, Yazad |
collection | PubMed |
description | Dental implants have been in vogue for more than three decades as a successful mode of rehabilitation of lost dentition. With time, there have been updates in methods and science including a positive tilt toward incorporation of digital technology into treatment protocols. This report elucidates a rare case of faulty osteotomy preparation through a computer-aided design computer-aided manufacturing stent that was detected and corrected before implant placement. The manuscript also emphasizes the possible shrinkage of soft-tissue graft beyond the normal postulated time frame and the importance of periodical checks on the drilling protocol throughout the flapless placement procedure even though it may have been seamlessly planned on the digital platform. |
format | Online Article Text |
id | pubmed-8051656 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-80516562021-04-23 Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy Gandhi, Yazad Natl J Maxillofac Surg Case Report Dental implants have been in vogue for more than three decades as a successful mode of rehabilitation of lost dentition. With time, there have been updates in methods and science including a positive tilt toward incorporation of digital technology into treatment protocols. This report elucidates a rare case of faulty osteotomy preparation through a computer-aided design computer-aided manufacturing stent that was detected and corrected before implant placement. The manuscript also emphasizes the possible shrinkage of soft-tissue graft beyond the normal postulated time frame and the importance of periodical checks on the drilling protocol throughout the flapless placement procedure even though it may have been seamlessly planned on the digital platform. Wolters Kluwer - Medknow 2020 2020-12-16 /pmc/articles/PMC8051656/ /pubmed/33897200 http://dx.doi.org/10.4103/njms.NJMS_51_20 Text en Copyright: © 2020 National Journal of Maxillofacial Surgery https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Gandhi, Yazad Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy |
title | Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy |
title_full | Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy |
title_fullStr | Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy |
title_full_unstemmed | Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy |
title_short | Dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy |
title_sort | dimensional changes in soft tissue as a plausible cause for error in computer-aided design and computer-aided manufacturing stent-guided implant osteotomy |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8051656/ https://www.ncbi.nlm.nih.gov/pubmed/33897200 http://dx.doi.org/10.4103/njms.NJMS_51_20 |
work_keys_str_mv | AT gandhiyazad dimensionalchangesinsofttissueasaplausiblecauseforerrorincomputeraideddesignandcomputeraidedmanufacturingstentguidedimplantosteotomy |