Cargando…
Vertical tank capacity measurement based on Monte Carlo method
Vertical tanks are commonly used appliances for liquids, and its capacity is very important for quantitative liquid ratio and liquid trade. In order to measure the capacity of vertical tanks more conveniently, this paper proposes a vertical tank capacity measurement method based on Monte Carlo Metho...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8051814/ https://www.ncbi.nlm.nih.gov/pubmed/33861774 http://dx.doi.org/10.1371/journal.pone.0250207 |
_version_ | 1783679806357897216 |
---|---|
author | Chen, Guoyu Wan, Yong Lin, Huanhuan Hu, Houlin Liu, Guixiong Peng, Yanhua |
author_facet | Chen, Guoyu Wan, Yong Lin, Huanhuan Hu, Houlin Liu, Guixiong Peng, Yanhua |
author_sort | Chen, Guoyu |
collection | PubMed |
description | Vertical tanks are commonly used appliances for liquids, and its capacity is very important for quantitative liquid ratio and liquid trade. In order to measure the capacity of vertical tanks more conveniently, this paper proposes a vertical tank capacity measurement method based on Monte Carlo Method. The method arranges a plurality of sensor points on the inner surface of the tank, and then performs Monte Carlo tests by generating a large number of random sample points, and finally calculates the capacity by counting the sample points that meet the criterion. The criterion for whether a sample point is located in the tank, which is the core issue, is established with the coordinates of sensor points and the distance between different sensor points along the surface of the tank. The results show that the absolute error of the measurement results of the proposed method does not exceed ±0.0003[m(3)], and the absolute error of capacity per unit volume has a linear relationship with the height of the vertical tank, and has little effect with the radial size of the vertical tank. |
format | Online Article Text |
id | pubmed-8051814 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-80518142021-04-28 Vertical tank capacity measurement based on Monte Carlo method Chen, Guoyu Wan, Yong Lin, Huanhuan Hu, Houlin Liu, Guixiong Peng, Yanhua PLoS One Research Article Vertical tanks are commonly used appliances for liquids, and its capacity is very important for quantitative liquid ratio and liquid trade. In order to measure the capacity of vertical tanks more conveniently, this paper proposes a vertical tank capacity measurement method based on Monte Carlo Method. The method arranges a plurality of sensor points on the inner surface of the tank, and then performs Monte Carlo tests by generating a large number of random sample points, and finally calculates the capacity by counting the sample points that meet the criterion. The criterion for whether a sample point is located in the tank, which is the core issue, is established with the coordinates of sensor points and the distance between different sensor points along the surface of the tank. The results show that the absolute error of the measurement results of the proposed method does not exceed ±0.0003[m(3)], and the absolute error of capacity per unit volume has a linear relationship with the height of the vertical tank, and has little effect with the radial size of the vertical tank. Public Library of Science 2021-04-16 /pmc/articles/PMC8051814/ /pubmed/33861774 http://dx.doi.org/10.1371/journal.pone.0250207 Text en © 2021 Chen et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Chen, Guoyu Wan, Yong Lin, Huanhuan Hu, Houlin Liu, Guixiong Peng, Yanhua Vertical tank capacity measurement based on Monte Carlo method |
title | Vertical tank capacity measurement based on Monte Carlo method |
title_full | Vertical tank capacity measurement based on Monte Carlo method |
title_fullStr | Vertical tank capacity measurement based on Monte Carlo method |
title_full_unstemmed | Vertical tank capacity measurement based on Monte Carlo method |
title_short | Vertical tank capacity measurement based on Monte Carlo method |
title_sort | vertical tank capacity measurement based on monte carlo method |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8051814/ https://www.ncbi.nlm.nih.gov/pubmed/33861774 http://dx.doi.org/10.1371/journal.pone.0250207 |
work_keys_str_mv | AT chenguoyu verticaltankcapacitymeasurementbasedonmontecarlomethod AT wanyong verticaltankcapacitymeasurementbasedonmontecarlomethod AT linhuanhuan verticaltankcapacitymeasurementbasedonmontecarlomethod AT huhoulin verticaltankcapacitymeasurementbasedonmontecarlomethod AT liuguixiong verticaltankcapacitymeasurementbasedonmontecarlomethod AT pengyanhua verticaltankcapacitymeasurementbasedonmontecarlomethod |