Cargando…

Vertical tank capacity measurement based on Monte Carlo method

Vertical tanks are commonly used appliances for liquids, and its capacity is very important for quantitative liquid ratio and liquid trade. In order to measure the capacity of vertical tanks more conveniently, this paper proposes a vertical tank capacity measurement method based on Monte Carlo Metho...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Guoyu, Wan, Yong, Lin, Huanhuan, Hu, Houlin, Liu, Guixiong, Peng, Yanhua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8051814/
https://www.ncbi.nlm.nih.gov/pubmed/33861774
http://dx.doi.org/10.1371/journal.pone.0250207
_version_ 1783679806357897216
author Chen, Guoyu
Wan, Yong
Lin, Huanhuan
Hu, Houlin
Liu, Guixiong
Peng, Yanhua
author_facet Chen, Guoyu
Wan, Yong
Lin, Huanhuan
Hu, Houlin
Liu, Guixiong
Peng, Yanhua
author_sort Chen, Guoyu
collection PubMed
description Vertical tanks are commonly used appliances for liquids, and its capacity is very important for quantitative liquid ratio and liquid trade. In order to measure the capacity of vertical tanks more conveniently, this paper proposes a vertical tank capacity measurement method based on Monte Carlo Method. The method arranges a plurality of sensor points on the inner surface of the tank, and then performs Monte Carlo tests by generating a large number of random sample points, and finally calculates the capacity by counting the sample points that meet the criterion. The criterion for whether a sample point is located in the tank, which is the core issue, is established with the coordinates of sensor points and the distance between different sensor points along the surface of the tank. The results show that the absolute error of the measurement results of the proposed method does not exceed ±0.0003[m(3)], and the absolute error of capacity per unit volume has a linear relationship with the height of the vertical tank, and has little effect with the radial size of the vertical tank.
format Online
Article
Text
id pubmed-8051814
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-80518142021-04-28 Vertical tank capacity measurement based on Monte Carlo method Chen, Guoyu Wan, Yong Lin, Huanhuan Hu, Houlin Liu, Guixiong Peng, Yanhua PLoS One Research Article Vertical tanks are commonly used appliances for liquids, and its capacity is very important for quantitative liquid ratio and liquid trade. In order to measure the capacity of vertical tanks more conveniently, this paper proposes a vertical tank capacity measurement method based on Monte Carlo Method. The method arranges a plurality of sensor points on the inner surface of the tank, and then performs Monte Carlo tests by generating a large number of random sample points, and finally calculates the capacity by counting the sample points that meet the criterion. The criterion for whether a sample point is located in the tank, which is the core issue, is established with the coordinates of sensor points and the distance between different sensor points along the surface of the tank. The results show that the absolute error of the measurement results of the proposed method does not exceed ±0.0003[m(3)], and the absolute error of capacity per unit volume has a linear relationship with the height of the vertical tank, and has little effect with the radial size of the vertical tank. Public Library of Science 2021-04-16 /pmc/articles/PMC8051814/ /pubmed/33861774 http://dx.doi.org/10.1371/journal.pone.0250207 Text en © 2021 Chen et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Chen, Guoyu
Wan, Yong
Lin, Huanhuan
Hu, Houlin
Liu, Guixiong
Peng, Yanhua
Vertical tank capacity measurement based on Monte Carlo method
title Vertical tank capacity measurement based on Monte Carlo method
title_full Vertical tank capacity measurement based on Monte Carlo method
title_fullStr Vertical tank capacity measurement based on Monte Carlo method
title_full_unstemmed Vertical tank capacity measurement based on Monte Carlo method
title_short Vertical tank capacity measurement based on Monte Carlo method
title_sort vertical tank capacity measurement based on monte carlo method
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8051814/
https://www.ncbi.nlm.nih.gov/pubmed/33861774
http://dx.doi.org/10.1371/journal.pone.0250207
work_keys_str_mv AT chenguoyu verticaltankcapacitymeasurementbasedonmontecarlomethod
AT wanyong verticaltankcapacitymeasurementbasedonmontecarlomethod
AT linhuanhuan verticaltankcapacitymeasurementbasedonmontecarlomethod
AT huhoulin verticaltankcapacitymeasurementbasedonmontecarlomethod
AT liuguixiong verticaltankcapacitymeasurementbasedonmontecarlomethod
AT pengyanhua verticaltankcapacitymeasurementbasedonmontecarlomethod