The Pulsatile Modification Improves Hemodynamics and Attenuates Inflammatory Responses in Extracorporeal Membrane Oxygenation

BACKGROUND: COVID-19 is still a worldwide pandemic and extracorporeal membrane oxygenation (ECMO) is vital for extremely critical COVID-19 patients. Pulsatile flow impacts greatly on organ function and microcirculation, however, the effects of pulsatile flow on hemodynamics and inflammatory response...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Guanhua, Zeng, Jianfeng, Liu, Zhaoyuan, Zhang, Yu, Fan, Xiaoping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8052115/
https://www.ncbi.nlm.nih.gov/pubmed/33880051
http://dx.doi.org/10.2147/JIR.S292543
_version_ 1783679860957249536
author Li, Guanhua
Zeng, Jianfeng
Liu, Zhaoyuan
Zhang, Yu
Fan, Xiaoping
author_facet Li, Guanhua
Zeng, Jianfeng
Liu, Zhaoyuan
Zhang, Yu
Fan, Xiaoping
author_sort Li, Guanhua
collection PubMed
description BACKGROUND: COVID-19 is still a worldwide pandemic and extracorporeal membrane oxygenation (ECMO) is vital for extremely critical COVID-19 patients. Pulsatile flow impacts greatly on organ function and microcirculation, however, the effects of pulsatile flow on hemodynamics and inflammatory responses during ECMO are unknown. An in vivo study was launched aiming at comparing the two perfusion modes in ECMO. METHODS: Fourteen beagles were randomly allocated into two groups: the pulsatile group (n=7) and the non-pulsatile group (n=7). ECMO was conducted using the i-Cor system for 24 hours. Hemodynamic parameters including surplus hemodynamic energy (SHE), energy equivalent pressure (EEP), oxygenator pressure drop (OPD), and circuit pressure drop (CPD) were monitored. To assess inflammatory responses during ECMO, levels of tumor necrosis factor-α (TNF-α), interleukin-1β (IL-1β), IL-6, IL-8, and transforming growth factor-β1 (TGF-β1) were measured. RESULTS: EEP and SHE were markedly higher in pulsatile circuits when compared with the conventional circuits. Between-group differences in both OPD and CPD reached statistical significance. Significant decreases in TNF-α were seen in animals treated with pulsatile flows at 2 hours, 12 hours, and 24 hours as well as a decrease in IL-1β at 24 hours during ECMO. The TGF-β1 levels were significantly higher in pulsatile circuits from 2 hours to 24 hours. The changes in IL-6 and IL-8 levels were insignificant. CONCLUSION: The modification of pulsatility in ECMO generates more hemodynamic energies and attenuates inflammatory responses as compared to the conventional non-pulsatile ECMO.
format Online
Article
Text
id pubmed-8052115
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-80521152021-04-19 The Pulsatile Modification Improves Hemodynamics and Attenuates Inflammatory Responses in Extracorporeal Membrane Oxygenation Li, Guanhua Zeng, Jianfeng Liu, Zhaoyuan Zhang, Yu Fan, Xiaoping J Inflamm Res Original Research BACKGROUND: COVID-19 is still a worldwide pandemic and extracorporeal membrane oxygenation (ECMO) is vital for extremely critical COVID-19 patients. Pulsatile flow impacts greatly on organ function and microcirculation, however, the effects of pulsatile flow on hemodynamics and inflammatory responses during ECMO are unknown. An in vivo study was launched aiming at comparing the two perfusion modes in ECMO. METHODS: Fourteen beagles were randomly allocated into two groups: the pulsatile group (n=7) and the non-pulsatile group (n=7). ECMO was conducted using the i-Cor system for 24 hours. Hemodynamic parameters including surplus hemodynamic energy (SHE), energy equivalent pressure (EEP), oxygenator pressure drop (OPD), and circuit pressure drop (CPD) were monitored. To assess inflammatory responses during ECMO, levels of tumor necrosis factor-α (TNF-α), interleukin-1β (IL-1β), IL-6, IL-8, and transforming growth factor-β1 (TGF-β1) were measured. RESULTS: EEP and SHE were markedly higher in pulsatile circuits when compared with the conventional circuits. Between-group differences in both OPD and CPD reached statistical significance. Significant decreases in TNF-α were seen in animals treated with pulsatile flows at 2 hours, 12 hours, and 24 hours as well as a decrease in IL-1β at 24 hours during ECMO. The TGF-β1 levels were significantly higher in pulsatile circuits from 2 hours to 24 hours. The changes in IL-6 and IL-8 levels were insignificant. CONCLUSION: The modification of pulsatility in ECMO generates more hemodynamic energies and attenuates inflammatory responses as compared to the conventional non-pulsatile ECMO. Dove 2021-04-12 /pmc/articles/PMC8052115/ /pubmed/33880051 http://dx.doi.org/10.2147/JIR.S292543 Text en © 2021 Li et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Li, Guanhua
Zeng, Jianfeng
Liu, Zhaoyuan
Zhang, Yu
Fan, Xiaoping
The Pulsatile Modification Improves Hemodynamics and Attenuates Inflammatory Responses in Extracorporeal Membrane Oxygenation
title The Pulsatile Modification Improves Hemodynamics and Attenuates Inflammatory Responses in Extracorporeal Membrane Oxygenation
title_full The Pulsatile Modification Improves Hemodynamics and Attenuates Inflammatory Responses in Extracorporeal Membrane Oxygenation
title_fullStr The Pulsatile Modification Improves Hemodynamics and Attenuates Inflammatory Responses in Extracorporeal Membrane Oxygenation
title_full_unstemmed The Pulsatile Modification Improves Hemodynamics and Attenuates Inflammatory Responses in Extracorporeal Membrane Oxygenation
title_short The Pulsatile Modification Improves Hemodynamics and Attenuates Inflammatory Responses in Extracorporeal Membrane Oxygenation
title_sort pulsatile modification improves hemodynamics and attenuates inflammatory responses in extracorporeal membrane oxygenation
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8052115/
https://www.ncbi.nlm.nih.gov/pubmed/33880051
http://dx.doi.org/10.2147/JIR.S292543
work_keys_str_mv AT liguanhua thepulsatilemodificationimproveshemodynamicsandattenuatesinflammatoryresponsesinextracorporealmembraneoxygenation
AT zengjianfeng thepulsatilemodificationimproveshemodynamicsandattenuatesinflammatoryresponsesinextracorporealmembraneoxygenation
AT liuzhaoyuan thepulsatilemodificationimproveshemodynamicsandattenuatesinflammatoryresponsesinextracorporealmembraneoxygenation
AT zhangyu thepulsatilemodificationimproveshemodynamicsandattenuatesinflammatoryresponsesinextracorporealmembraneoxygenation
AT fanxiaoping thepulsatilemodificationimproveshemodynamicsandattenuatesinflammatoryresponsesinextracorporealmembraneoxygenation
AT liguanhua pulsatilemodificationimproveshemodynamicsandattenuatesinflammatoryresponsesinextracorporealmembraneoxygenation
AT zengjianfeng pulsatilemodificationimproveshemodynamicsandattenuatesinflammatoryresponsesinextracorporealmembraneoxygenation
AT liuzhaoyuan pulsatilemodificationimproveshemodynamicsandattenuatesinflammatoryresponsesinextracorporealmembraneoxygenation
AT zhangyu pulsatilemodificationimproveshemodynamicsandattenuatesinflammatoryresponsesinextracorporealmembraneoxygenation
AT fanxiaoping pulsatilemodificationimproveshemodynamicsandattenuatesinflammatoryresponsesinextracorporealmembraneoxygenation