Cargando…

Diagnostic accuracy of routine calcitonin measurement for the detection of medullary thyroid carcinoma in the management of patients with nodular thyroid disease: a meta-analysis

OBJECTIVE: The usefulness of routine calcitonin measurement for early detection of medullary thyroid carcinoma (MTC) in patients with nodular thyroid disease (NTD) has been investigated in various studies. Recently, a Cochrane review has been published on this issue, but a meta-analysis is lacking y...

Descripción completa

Detalles Bibliográficos
Autores principales: Vardarli, Irfan, Weber, Manuel, Weidemann, Frank, Führer, Dagmar, Herrmann, Ken, Görges, Rainer
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bioscientifica Ltd 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8052568/
https://www.ncbi.nlm.nih.gov/pubmed/33638941
http://dx.doi.org/10.1530/EC-21-0030
_version_ 1783679948336136192
author Vardarli, Irfan
Weber, Manuel
Weidemann, Frank
Führer, Dagmar
Herrmann, Ken
Görges, Rainer
author_facet Vardarli, Irfan
Weber, Manuel
Weidemann, Frank
Führer, Dagmar
Herrmann, Ken
Görges, Rainer
author_sort Vardarli, Irfan
collection PubMed
description OBJECTIVE: The usefulness of routine calcitonin measurement for early detection of medullary thyroid carcinoma (MTC) in patients with nodular thyroid disease (NTD) has been investigated in various studies. Recently, a Cochrane review has been published on this issue, but a meta-analysis is lacking yet. Therefore, we performed this meta-analysis. METHODS: We performed an electronic search using PubMed/Medline, Embase and the Cochrane Library. Studies assessing the diagnostic accuracy of routine calcitonin measurement for detecting MTC in patients with NDT were selected. Statistics were performed by using Stata software, risk of bias was assessed using Review Manager version 5.3. RESULTS: Seventeen studies, involving 74,407 patients were included in the study. Meta-analysis, using the bivariate random effects model and the hierarchical summary receiver operating characteristic (HSROC) curve revealed the following pooled estimates: sensitivity 0.99 (95% CI, 0.81–1.00), specificity 0.99 (95% CI, 0.97–0.99), positive likelihood ratio (L+) 72.4 (95% CI, 32.3–162.1), and negative likelihood ratio (L−) 0.01 (95% CI, 0.00–0.23). Meta-regression analysis showed that the threshold of basal calcitonin is an independent factor, but in particular performing stimulation test is not an independent factor. CONCLUSIONS: We showed that routine basal serum calcitonin measurement in the management of patients with thyroid nodules is valuable for the detection of MTC. However, the published cut-off values should be considered and, if applicable, the patients monitored in a wait-and-see strategy by experienced physicians to avoid overtreatment.
format Online
Article
Text
id pubmed-8052568
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Bioscientifica Ltd
record_format MEDLINE/PubMed
spelling pubmed-80525682021-04-21 Diagnostic accuracy of routine calcitonin measurement for the detection of medullary thyroid carcinoma in the management of patients with nodular thyroid disease: a meta-analysis Vardarli, Irfan Weber, Manuel Weidemann, Frank Führer, Dagmar Herrmann, Ken Görges, Rainer Endocr Connect Research OBJECTIVE: The usefulness of routine calcitonin measurement for early detection of medullary thyroid carcinoma (MTC) in patients with nodular thyroid disease (NTD) has been investigated in various studies. Recently, a Cochrane review has been published on this issue, but a meta-analysis is lacking yet. Therefore, we performed this meta-analysis. METHODS: We performed an electronic search using PubMed/Medline, Embase and the Cochrane Library. Studies assessing the diagnostic accuracy of routine calcitonin measurement for detecting MTC in patients with NDT were selected. Statistics were performed by using Stata software, risk of bias was assessed using Review Manager version 5.3. RESULTS: Seventeen studies, involving 74,407 patients were included in the study. Meta-analysis, using the bivariate random effects model and the hierarchical summary receiver operating characteristic (HSROC) curve revealed the following pooled estimates: sensitivity 0.99 (95% CI, 0.81–1.00), specificity 0.99 (95% CI, 0.97–0.99), positive likelihood ratio (L+) 72.4 (95% CI, 32.3–162.1), and negative likelihood ratio (L−) 0.01 (95% CI, 0.00–0.23). Meta-regression analysis showed that the threshold of basal calcitonin is an independent factor, but in particular performing stimulation test is not an independent factor. CONCLUSIONS: We showed that routine basal serum calcitonin measurement in the management of patients with thyroid nodules is valuable for the detection of MTC. However, the published cut-off values should be considered and, if applicable, the patients monitored in a wait-and-see strategy by experienced physicians to avoid overtreatment. Bioscientifica Ltd 2021-02-25 /pmc/articles/PMC8052568/ /pubmed/33638941 http://dx.doi.org/10.1530/EC-21-0030 Text en © 2021 The authors https://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Research
Vardarli, Irfan
Weber, Manuel
Weidemann, Frank
Führer, Dagmar
Herrmann, Ken
Görges, Rainer
Diagnostic accuracy of routine calcitonin measurement for the detection of medullary thyroid carcinoma in the management of patients with nodular thyroid disease: a meta-analysis
title Diagnostic accuracy of routine calcitonin measurement for the detection of medullary thyroid carcinoma in the management of patients with nodular thyroid disease: a meta-analysis
title_full Diagnostic accuracy of routine calcitonin measurement for the detection of medullary thyroid carcinoma in the management of patients with nodular thyroid disease: a meta-analysis
title_fullStr Diagnostic accuracy of routine calcitonin measurement for the detection of medullary thyroid carcinoma in the management of patients with nodular thyroid disease: a meta-analysis
title_full_unstemmed Diagnostic accuracy of routine calcitonin measurement for the detection of medullary thyroid carcinoma in the management of patients with nodular thyroid disease: a meta-analysis
title_short Diagnostic accuracy of routine calcitonin measurement for the detection of medullary thyroid carcinoma in the management of patients with nodular thyroid disease: a meta-analysis
title_sort diagnostic accuracy of routine calcitonin measurement for the detection of medullary thyroid carcinoma in the management of patients with nodular thyroid disease: a meta-analysis
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8052568/
https://www.ncbi.nlm.nih.gov/pubmed/33638941
http://dx.doi.org/10.1530/EC-21-0030
work_keys_str_mv AT vardarliirfan diagnosticaccuracyofroutinecalcitoninmeasurementforthedetectionofmedullarythyroidcarcinomainthemanagementofpatientswithnodularthyroiddiseaseametaanalysis
AT webermanuel diagnosticaccuracyofroutinecalcitoninmeasurementforthedetectionofmedullarythyroidcarcinomainthemanagementofpatientswithnodularthyroiddiseaseametaanalysis
AT weidemannfrank diagnosticaccuracyofroutinecalcitoninmeasurementforthedetectionofmedullarythyroidcarcinomainthemanagementofpatientswithnodularthyroiddiseaseametaanalysis
AT fuhrerdagmar diagnosticaccuracyofroutinecalcitoninmeasurementforthedetectionofmedullarythyroidcarcinomainthemanagementofpatientswithnodularthyroiddiseaseametaanalysis
AT herrmannken diagnosticaccuracyofroutinecalcitoninmeasurementforthedetectionofmedullarythyroidcarcinomainthemanagementofpatientswithnodularthyroiddiseaseametaanalysis
AT gorgesrainer diagnosticaccuracyofroutinecalcitoninmeasurementforthedetectionofmedullarythyroidcarcinomainthemanagementofpatientswithnodularthyroiddiseaseametaanalysis