Cargando…
Comparison of Multiple Diagnostic Tests to Measure Dynamic Hyperinflation in Patients with Severe Emphysema Treated with Endobronchial Coils
PURPOSE: For this study, we aimed to compare dynamic hyperinflation measured by cardiopulmonary exercise testing (CPET), a six-minute walking test (6-MWT), and a manually paced tachypnea test (MPT) in patients with severe emphysema who were treated with endobronchial coils. Additionally, we investig...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8053153/ https://www.ncbi.nlm.nih.gov/pubmed/33687513 http://dx.doi.org/10.1007/s00408-021-00430-0 |
_version_ | 1783680063774916608 |
---|---|
author | van Dijk, Marlies Hartman, Jorine E. Augustijn, Sonja W. S. ten Hacken, Nick H. T. Klooster, Karin Slebos, Dirk-Jan |
author_facet | van Dijk, Marlies Hartman, Jorine E. Augustijn, Sonja W. S. ten Hacken, Nick H. T. Klooster, Karin Slebos, Dirk-Jan |
author_sort | van Dijk, Marlies |
collection | PubMed |
description | PURPOSE: For this study, we aimed to compare dynamic hyperinflation measured by cardiopulmonary exercise testing (CPET), a six-minute walking test (6-MWT), and a manually paced tachypnea test (MPT) in patients with severe emphysema who were treated with endobronchial coils. Additionally, we investigated whether dynamic hyperinflation changed after treatment with endobronchial coils. METHODS: Dynamic hyperinflation was measured with CPET, 6-MWT, and an MPT in 29 patients before and after coil treatment. RESULTS: There was no significant change in dynamic hyperinflation after treatment with coils. Comparison of CPET and MPT showed a strong association (rho 0.660, p < 0.001) and a moderate agreement (BA-plot, 202 ml difference in favor of MPT). There was only a moderate association of the 6-MWT with CPET (rho 0.361, p 0.024). CONCLUSION: MPT can be a suitable alternative to CPET to measure dynamic hyperinflation in severe emphysema but may overestimate dynamic hyperinflation possibly due to a higher breathing frequency. |
format | Online Article Text |
id | pubmed-8053153 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-80531532021-04-29 Comparison of Multiple Diagnostic Tests to Measure Dynamic Hyperinflation in Patients with Severe Emphysema Treated with Endobronchial Coils van Dijk, Marlies Hartman, Jorine E. Augustijn, Sonja W. S. ten Hacken, Nick H. T. Klooster, Karin Slebos, Dirk-Jan Lung COPD and INTERVENTIONAL PULMONOLOGY PURPOSE: For this study, we aimed to compare dynamic hyperinflation measured by cardiopulmonary exercise testing (CPET), a six-minute walking test (6-MWT), and a manually paced tachypnea test (MPT) in patients with severe emphysema who were treated with endobronchial coils. Additionally, we investigated whether dynamic hyperinflation changed after treatment with endobronchial coils. METHODS: Dynamic hyperinflation was measured with CPET, 6-MWT, and an MPT in 29 patients before and after coil treatment. RESULTS: There was no significant change in dynamic hyperinflation after treatment with coils. Comparison of CPET and MPT showed a strong association (rho 0.660, p < 0.001) and a moderate agreement (BA-plot, 202 ml difference in favor of MPT). There was only a moderate association of the 6-MWT with CPET (rho 0.361, p 0.024). CONCLUSION: MPT can be a suitable alternative to CPET to measure dynamic hyperinflation in severe emphysema but may overestimate dynamic hyperinflation possibly due to a higher breathing frequency. Springer US 2021-03-09 2021 /pmc/articles/PMC8053153/ /pubmed/33687513 http://dx.doi.org/10.1007/s00408-021-00430-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | COPD and INTERVENTIONAL PULMONOLOGY van Dijk, Marlies Hartman, Jorine E. Augustijn, Sonja W. S. ten Hacken, Nick H. T. Klooster, Karin Slebos, Dirk-Jan Comparison of Multiple Diagnostic Tests to Measure Dynamic Hyperinflation in Patients with Severe Emphysema Treated with Endobronchial Coils |
title | Comparison of Multiple Diagnostic Tests to Measure Dynamic Hyperinflation in Patients with Severe Emphysema Treated with Endobronchial Coils |
title_full | Comparison of Multiple Diagnostic Tests to Measure Dynamic Hyperinflation in Patients with Severe Emphysema Treated with Endobronchial Coils |
title_fullStr | Comparison of Multiple Diagnostic Tests to Measure Dynamic Hyperinflation in Patients with Severe Emphysema Treated with Endobronchial Coils |
title_full_unstemmed | Comparison of Multiple Diagnostic Tests to Measure Dynamic Hyperinflation in Patients with Severe Emphysema Treated with Endobronchial Coils |
title_short | Comparison of Multiple Diagnostic Tests to Measure Dynamic Hyperinflation in Patients with Severe Emphysema Treated with Endobronchial Coils |
title_sort | comparison of multiple diagnostic tests to measure dynamic hyperinflation in patients with severe emphysema treated with endobronchial coils |
topic | COPD and INTERVENTIONAL PULMONOLOGY |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8053153/ https://www.ncbi.nlm.nih.gov/pubmed/33687513 http://dx.doi.org/10.1007/s00408-021-00430-0 |
work_keys_str_mv | AT vandijkmarlies comparisonofmultiplediagnosticteststomeasuredynamichyperinflationinpatientswithsevereemphysematreatedwithendobronchialcoils AT hartmanjorinee comparisonofmultiplediagnosticteststomeasuredynamichyperinflationinpatientswithsevereemphysematreatedwithendobronchialcoils AT augustijnsonjaws comparisonofmultiplediagnosticteststomeasuredynamichyperinflationinpatientswithsevereemphysematreatedwithendobronchialcoils AT tenhackennickht comparisonofmultiplediagnosticteststomeasuredynamichyperinflationinpatientswithsevereemphysematreatedwithendobronchialcoils AT kloosterkarin comparisonofmultiplediagnosticteststomeasuredynamichyperinflationinpatientswithsevereemphysematreatedwithendobronchialcoils AT slebosdirkjan comparisonofmultiplediagnosticteststomeasuredynamichyperinflationinpatientswithsevereemphysematreatedwithendobronchialcoils |