Use of the XEN gel implant in a patient with aniridia-associated glaucoma
PURPOSE: To report on the implantation of a XEN 45 gel implant in a patient with glaucoma associated with congenital aniridia. OBSERVATIONS: A 60-year old man with familial congenital aniridia and glaucoma presented with intraocular pressure of 30 mmHg in his right eye despite maximal topical treatm...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8056218/ https://www.ncbi.nlm.nih.gov/pubmed/33898859 http://dx.doi.org/10.1016/j.ajoc.2021.101080 |
_version_ | 1783680607139659776 |
---|---|
author | Lindland, Are Edward Michelet, John-Thomas Slagsvold, Jon Erik |
author_facet | Lindland, Are Edward Michelet, John-Thomas Slagsvold, Jon Erik |
author_sort | Lindland, Are |
collection | PubMed |
description | PURPOSE: To report on the implantation of a XEN 45 gel implant in a patient with glaucoma associated with congenital aniridia. OBSERVATIONS: A 60-year old man with familial congenital aniridia and glaucoma presented with intraocular pressure of 30 mmHg in his right eye despite maximal topical treatment with four medications. Implantation of a XEN gel stent was performed without complications after subconjunctival injection of mitomycin-C (0.1 mL of 0.02%). At the two-year follow-up, the patient's intraocular pressure was 12 mmHg with one topical medication. No needling of the filtering bleb was required. No excessive fibrosis of the conjunctiva or worsening of the existing keratopathy was noted. CONCLUSIONS: The XEN 45 implant could be an option in the treatment of aniridia-associated glaucoma. |
format | Online Article Text |
id | pubmed-8056218 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-80562182021-04-23 Use of the XEN gel implant in a patient with aniridia-associated glaucoma Lindland, Are Edward Michelet, John-Thomas Slagsvold, Jon Erik Am J Ophthalmol Case Rep Case Report PURPOSE: To report on the implantation of a XEN 45 gel implant in a patient with glaucoma associated with congenital aniridia. OBSERVATIONS: A 60-year old man with familial congenital aniridia and glaucoma presented with intraocular pressure of 30 mmHg in his right eye despite maximal topical treatment with four medications. Implantation of a XEN gel stent was performed without complications after subconjunctival injection of mitomycin-C (0.1 mL of 0.02%). At the two-year follow-up, the patient's intraocular pressure was 12 mmHg with one topical medication. No needling of the filtering bleb was required. No excessive fibrosis of the conjunctiva or worsening of the existing keratopathy was noted. CONCLUSIONS: The XEN 45 implant could be an option in the treatment of aniridia-associated glaucoma. Elsevier 2021-03-31 /pmc/articles/PMC8056218/ /pubmed/33898859 http://dx.doi.org/10.1016/j.ajoc.2021.101080 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Lindland, Are Edward Michelet, John-Thomas Slagsvold, Jon Erik Use of the XEN gel implant in a patient with aniridia-associated glaucoma |
title | Use of the XEN gel implant in a patient with aniridia-associated glaucoma |
title_full | Use of the XEN gel implant in a patient with aniridia-associated glaucoma |
title_fullStr | Use of the XEN gel implant in a patient with aniridia-associated glaucoma |
title_full_unstemmed | Use of the XEN gel implant in a patient with aniridia-associated glaucoma |
title_short | Use of the XEN gel implant in a patient with aniridia-associated glaucoma |
title_sort | use of the xen gel implant in a patient with aniridia-associated glaucoma |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8056218/ https://www.ncbi.nlm.nih.gov/pubmed/33898859 http://dx.doi.org/10.1016/j.ajoc.2021.101080 |
work_keys_str_mv | AT lindlandare useofthexengelimplantinapatientwithaniridiaassociatedglaucoma AT edwardmicheletjohnthomas useofthexengelimplantinapatientwithaniridiaassociatedglaucoma AT slagsvoldjonerik useofthexengelimplantinapatientwithaniridiaassociatedglaucoma |