Cargando…
Variation of heart and lung radiation doses according to setup uncertainty in left breast cancer
PURPOSE: Breast radiotherapy set-up is often uncertain. Actual dose distribution to normal tissues could be different from planned dose distribution. The objective of this study was to investigate such difference in dose distribution according to the extent of set-up error in breast radiotherapy. MA...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8056628/ https://www.ncbi.nlm.nih.gov/pubmed/33879201 http://dx.doi.org/10.1186/s13014-021-01806-5 |
_version_ | 1783680685580484608 |
---|---|
author | Park, Sunmin Rim, Chai Hong Yoon, Won Sup |
author_facet | Park, Sunmin Rim, Chai Hong Yoon, Won Sup |
author_sort | Park, Sunmin |
collection | PubMed |
description | PURPOSE: Breast radiotherapy set-up is often uncertain. Actual dose distribution to normal tissues could be different from planned dose distribution. The objective of this study was to investigate such difference in dose distribution according to the extent of set-up error in breast radiotherapy. MATERIALS AND METHODS: A total of 50 Gy with fraction size of 2 Gy was given to 30 left breasts with different set-ups applying a deep inspiration breath holding (DIBH) or a free breathing (FB) technique. Under the assumption that errors might come from translational axes of deep or caudal directions, the isocenter was shifted from the original tangential alignment every 2.5 mm to simulate uncertainty of deep and caudal tangential set-up in DIBH and FB. Changes were evaluated for dosimetric parameters for the heart, the left ventricle (LV), the left anterior descending coronary artery (LAD), and the ipsilateral lung. RESULTS: On the original plan, mean doses of heart and ipsilateral lung were 2.0 ± 1.1 Gy and 3.7 ± 1.4 Gy in DIBH and 8.4 ± 1.3 Gy and 7.8 ± 1.5 Gy in FB, respectively. The change of dose distribution for the heart in DIBH was milder than that in FB. The deeper the tangential set-up, the worse the heart, LV, LAD, and ipsilateral lung doses, showing as much as 49.4%, 56.4%, 90.3%, and 26.1% shifts, respectively, in 5 mm DIBH setup. The caudal set-up did not show significant dose difference. In multiple comparison of DIBH, differences of mean dose occurred in all 7.5 mm deep set-ups for the heart (p = 0.025), the LV (p = 0.049), and LAD (p = 0.025) in DIBH. CONCLUSIONS: To correct set-up error over indicated limitation for deep tangential set-up in DIBH at 5 mm action level, mean heart and ipsilateral lung doses are expected to increase approximately 50% and 25%, respectively. |
format | Online Article Text |
id | pubmed-8056628 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-80566282021-04-20 Variation of heart and lung radiation doses according to setup uncertainty in left breast cancer Park, Sunmin Rim, Chai Hong Yoon, Won Sup Radiat Oncol Research PURPOSE: Breast radiotherapy set-up is often uncertain. Actual dose distribution to normal tissues could be different from planned dose distribution. The objective of this study was to investigate such difference in dose distribution according to the extent of set-up error in breast radiotherapy. MATERIALS AND METHODS: A total of 50 Gy with fraction size of 2 Gy was given to 30 left breasts with different set-ups applying a deep inspiration breath holding (DIBH) or a free breathing (FB) technique. Under the assumption that errors might come from translational axes of deep or caudal directions, the isocenter was shifted from the original tangential alignment every 2.5 mm to simulate uncertainty of deep and caudal tangential set-up in DIBH and FB. Changes were evaluated for dosimetric parameters for the heart, the left ventricle (LV), the left anterior descending coronary artery (LAD), and the ipsilateral lung. RESULTS: On the original plan, mean doses of heart and ipsilateral lung were 2.0 ± 1.1 Gy and 3.7 ± 1.4 Gy in DIBH and 8.4 ± 1.3 Gy and 7.8 ± 1.5 Gy in FB, respectively. The change of dose distribution for the heart in DIBH was milder than that in FB. The deeper the tangential set-up, the worse the heart, LV, LAD, and ipsilateral lung doses, showing as much as 49.4%, 56.4%, 90.3%, and 26.1% shifts, respectively, in 5 mm DIBH setup. The caudal set-up did not show significant dose difference. In multiple comparison of DIBH, differences of mean dose occurred in all 7.5 mm deep set-ups for the heart (p = 0.025), the LV (p = 0.049), and LAD (p = 0.025) in DIBH. CONCLUSIONS: To correct set-up error over indicated limitation for deep tangential set-up in DIBH at 5 mm action level, mean heart and ipsilateral lung doses are expected to increase approximately 50% and 25%, respectively. BioMed Central 2021-04-20 /pmc/articles/PMC8056628/ /pubmed/33879201 http://dx.doi.org/10.1186/s13014-021-01806-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Park, Sunmin Rim, Chai Hong Yoon, Won Sup Variation of heart and lung radiation doses according to setup uncertainty in left breast cancer |
title | Variation of heart and lung radiation doses according to setup uncertainty in left breast cancer |
title_full | Variation of heart and lung radiation doses according to setup uncertainty in left breast cancer |
title_fullStr | Variation of heart and lung radiation doses according to setup uncertainty in left breast cancer |
title_full_unstemmed | Variation of heart and lung radiation doses according to setup uncertainty in left breast cancer |
title_short | Variation of heart and lung radiation doses according to setup uncertainty in left breast cancer |
title_sort | variation of heart and lung radiation doses according to setup uncertainty in left breast cancer |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8056628/ https://www.ncbi.nlm.nih.gov/pubmed/33879201 http://dx.doi.org/10.1186/s13014-021-01806-5 |
work_keys_str_mv | AT parksunmin variationofheartandlungradiationdosesaccordingtosetupuncertaintyinleftbreastcancer AT rimchaihong variationofheartandlungradiationdosesaccordingtosetupuncertaintyinleftbreastcancer AT yoonwonsup variationofheartandlungradiationdosesaccordingtosetupuncertaintyinleftbreastcancer |