Cargando…

Impact of interfractional target motion in locally advanced cervical cancer patients treated with spot scanning proton therapy using an internal target volume strategy

BACKGROUND AND PURPOSE: The more localized dose deposition of proton therapy (PT) compared to photon therapy might allow a reduction in treatment-related side effects but induces additional challenges to address. The aim of this study was to evaluate the impact of interfractional motion on the targe...

Descripción completa

Detalles Bibliográficos
Autores principales: Niyoteka, Stéphane, Berger, Thomas, Fokdal, Lars Ulrik, Petersen, Jørgen Breede Baltzer, Zolnay, Andras, Hoogeman, Mischa, Tanderup, Kari, Nystrom, Håkan Ulf
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8058016/
https://www.ncbi.nlm.nih.gov/pubmed/33898784
http://dx.doi.org/10.1016/j.phro.2021.01.010
_version_ 1783680945092558848
author Niyoteka, Stéphane
Berger, Thomas
Fokdal, Lars Ulrik
Petersen, Jørgen Breede Baltzer
Zolnay, Andras
Hoogeman, Mischa
Tanderup, Kari
Nystrom, Håkan Ulf
author_facet Niyoteka, Stéphane
Berger, Thomas
Fokdal, Lars Ulrik
Petersen, Jørgen Breede Baltzer
Zolnay, Andras
Hoogeman, Mischa
Tanderup, Kari
Nystrom, Håkan Ulf
author_sort Niyoteka, Stéphane
collection PubMed
description BACKGROUND AND PURPOSE: The more localized dose deposition of proton therapy (PT) compared to photon therapy might allow a reduction in treatment-related side effects but induces additional challenges to address. The aim of this study was to evaluate the impact of interfractional motion on the target and organs at risk (OARs) in cervical cancer patients treated with spot scanning PT using an internal target volume (ITV) strategy. METHODS AND MATERIALS: For ten locally advanced cervical cancer patients, empty and full bladder planning computed tomography (pCT) as well as 25 daily cone beam CTs (CBCTs) were available. The Clinical Target Volume (CTV), the High Risk CTV (CTV(HR)) (gross tumor volume and whole cervix), the non-involved uterus as well as the OARs (bowel, bladder and rectum) were contoured on the daily CBCTs and transferred to the pCT through rigid bony match. Using synthetic CTs derived from pCTs, four-beam spot scanning PT plans were generated to target the patient-specific ITV with 45 Gy(RBE) in 25 fractions. This structure was defined based on pre-treatment MRI and CT to anticipate potential target motion throughout the treatment. D98% of the targets and V40Gy(RBE) of the OARs were extracted from the daily anatomies, accumulated and analyzed. In addition, the impact of bladder volume deviations from planning values on target and bowel dose was investigated. RESULTS: The ITV strategy ensured a total accumulated dose >42.75 Gy(RBE) to the CTV(HR) for all ten patients. Two patients with large bladder-related uterus motion had accumulated dose to the non-involved uterus of 35.7 Gy(RBE) and 41.1 Gy(RBE). Variations in bowel V40Gy(RBE) were found to be correlated (Pearson r = −0.55; p-value <0.0001) with changes in bladder volume during treatment. CONCLUSION: The ITV concept ensured adequate dose to the CTV(HR), but was insufficient for the non-involved uterus of patients subject to large target interfractional motion. CBCT monitoring and occasional replanning is recommended along the same lines as with photon radiotherapy in cervical cancer.
format Online
Article
Text
id pubmed-8058016
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-80580162021-04-23 Impact of interfractional target motion in locally advanced cervical cancer patients treated with spot scanning proton therapy using an internal target volume strategy Niyoteka, Stéphane Berger, Thomas Fokdal, Lars Ulrik Petersen, Jørgen Breede Baltzer Zolnay, Andras Hoogeman, Mischa Tanderup, Kari Nystrom, Håkan Ulf Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: The more localized dose deposition of proton therapy (PT) compared to photon therapy might allow a reduction in treatment-related side effects but induces additional challenges to address. The aim of this study was to evaluate the impact of interfractional motion on the target and organs at risk (OARs) in cervical cancer patients treated with spot scanning PT using an internal target volume (ITV) strategy. METHODS AND MATERIALS: For ten locally advanced cervical cancer patients, empty and full bladder planning computed tomography (pCT) as well as 25 daily cone beam CTs (CBCTs) were available. The Clinical Target Volume (CTV), the High Risk CTV (CTV(HR)) (gross tumor volume and whole cervix), the non-involved uterus as well as the OARs (bowel, bladder and rectum) were contoured on the daily CBCTs and transferred to the pCT through rigid bony match. Using synthetic CTs derived from pCTs, four-beam spot scanning PT plans were generated to target the patient-specific ITV with 45 Gy(RBE) in 25 fractions. This structure was defined based on pre-treatment MRI and CT to anticipate potential target motion throughout the treatment. D98% of the targets and V40Gy(RBE) of the OARs were extracted from the daily anatomies, accumulated and analyzed. In addition, the impact of bladder volume deviations from planning values on target and bowel dose was investigated. RESULTS: The ITV strategy ensured a total accumulated dose >42.75 Gy(RBE) to the CTV(HR) for all ten patients. Two patients with large bladder-related uterus motion had accumulated dose to the non-involved uterus of 35.7 Gy(RBE) and 41.1 Gy(RBE). Variations in bowel V40Gy(RBE) were found to be correlated (Pearson r = −0.55; p-value <0.0001) with changes in bladder volume during treatment. CONCLUSION: The ITV concept ensured adequate dose to the CTV(HR), but was insufficient for the non-involved uterus of patients subject to large target interfractional motion. CBCT monitoring and occasional replanning is recommended along the same lines as with photon radiotherapy in cervical cancer. Elsevier 2021-02-06 /pmc/articles/PMC8058016/ /pubmed/33898784 http://dx.doi.org/10.1016/j.phro.2021.01.010 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research Article
Niyoteka, Stéphane
Berger, Thomas
Fokdal, Lars Ulrik
Petersen, Jørgen Breede Baltzer
Zolnay, Andras
Hoogeman, Mischa
Tanderup, Kari
Nystrom, Håkan Ulf
Impact of interfractional target motion in locally advanced cervical cancer patients treated with spot scanning proton therapy using an internal target volume strategy
title Impact of interfractional target motion in locally advanced cervical cancer patients treated with spot scanning proton therapy using an internal target volume strategy
title_full Impact of interfractional target motion in locally advanced cervical cancer patients treated with spot scanning proton therapy using an internal target volume strategy
title_fullStr Impact of interfractional target motion in locally advanced cervical cancer patients treated with spot scanning proton therapy using an internal target volume strategy
title_full_unstemmed Impact of interfractional target motion in locally advanced cervical cancer patients treated with spot scanning proton therapy using an internal target volume strategy
title_short Impact of interfractional target motion in locally advanced cervical cancer patients treated with spot scanning proton therapy using an internal target volume strategy
title_sort impact of interfractional target motion in locally advanced cervical cancer patients treated with spot scanning proton therapy using an internal target volume strategy
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8058016/
https://www.ncbi.nlm.nih.gov/pubmed/33898784
http://dx.doi.org/10.1016/j.phro.2021.01.010
work_keys_str_mv AT niyotekastephane impactofinterfractionaltargetmotioninlocallyadvancedcervicalcancerpatientstreatedwithspotscanningprotontherapyusinganinternaltargetvolumestrategy
AT bergerthomas impactofinterfractionaltargetmotioninlocallyadvancedcervicalcancerpatientstreatedwithspotscanningprotontherapyusinganinternaltargetvolumestrategy
AT fokdallarsulrik impactofinterfractionaltargetmotioninlocallyadvancedcervicalcancerpatientstreatedwithspotscanningprotontherapyusinganinternaltargetvolumestrategy
AT petersenjørgenbreedebaltzer impactofinterfractionaltargetmotioninlocallyadvancedcervicalcancerpatientstreatedwithspotscanningprotontherapyusinganinternaltargetvolumestrategy
AT zolnayandras impactofinterfractionaltargetmotioninlocallyadvancedcervicalcancerpatientstreatedwithspotscanningprotontherapyusinganinternaltargetvolumestrategy
AT hoogemanmischa impactofinterfractionaltargetmotioninlocallyadvancedcervicalcancerpatientstreatedwithspotscanningprotontherapyusinganinternaltargetvolumestrategy
AT tanderupkari impactofinterfractionaltargetmotioninlocallyadvancedcervicalcancerpatientstreatedwithspotscanningprotontherapyusinganinternaltargetvolumestrategy
AT nystromhakanulf impactofinterfractionaltargetmotioninlocallyadvancedcervicalcancerpatientstreatedwithspotscanningprotontherapyusinganinternaltargetvolumestrategy