Cargando…

Evaluation of image quality of a novel computed tomography metal artifact management technique on an anthropomorphic head and neck phantom

BACKGROUND AND PURPOSE: Artefacts caused by dental amalgam implants present a common challenge in computed tomography (CT) and therefore treatment planning dose calculations. The goal was to perform a quantitative image quality analysis of our Artifact Management for Proton Planning (AMPP) algorithm...

Descripción completa

Detalles Bibliográficos
Autores principales: Branco, Daniela, Kry, Stephen, Taylor, Paige, Rong, John, Zhang, Xiaodong, Frank, Steven, Followill, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8058027/
https://www.ncbi.nlm.nih.gov/pubmed/33898789
http://dx.doi.org/10.1016/j.phro.2021.01.007
_version_ 1783680947656327168
author Branco, Daniela
Kry, Stephen
Taylor, Paige
Rong, John
Zhang, Xiaodong
Frank, Steven
Followill, David
author_facet Branco, Daniela
Kry, Stephen
Taylor, Paige
Rong, John
Zhang, Xiaodong
Frank, Steven
Followill, David
author_sort Branco, Daniela
collection PubMed
description BACKGROUND AND PURPOSE: Artefacts caused by dental amalgam implants present a common challenge in computed tomography (CT) and therefore treatment planning dose calculations. The goal was to perform a quantitative image quality analysis of our Artifact Management for Proton Planning (AMPP) algorithm which used gantry tilts for managing metal artefacts on Head and Neck (HN) CT scans and major vendors’ commercial approaches. MATERIALS AND METHODS: Metal artefact reduction (MAR) algorithms were evaluated using an anthropomorphic phantom with a removable jaw for the acquisition of images with and without (baseline) metal artifacts. AMPP made use of two angled CT scans to generate one artifact-reduced image set. The MAR algorithms from four vendors were applied to the images with artefacts and the analysis was performed with respective baselines. Planar HU difference maps and volumetric HU differences were analyzed. RESULTS: AMPP algorithm outperformed all vendors’ commercial approaches in the elimination of artefacts in the oropharyngeal region, showing the lowest percent of pixels outside +− 20 HU criteria, 4%; whereas those in the MAR-corrected images ranged from 26% to 67%. In the region of interest within the affected slices, the commercial MAR algorithms showed inconsistent performance, whereas the AMPP algorithm performed consistently well throughout the phantom’s posterior region. CONCLUSIONS: A novel MAR algorithm was evaluated and compared to four commercial algorithms using an anthropomorphic phantom. Unanimously, the analysis showed the AMPP algorithm outperformed vendors’ commercial approaches, showing the potential to be broadly implemented, improve visualizations in patient anatomy and provide accurate HU information.
format Online
Article
Text
id pubmed-8058027
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-80580272021-04-23 Evaluation of image quality of a novel computed tomography metal artifact management technique on an anthropomorphic head and neck phantom Branco, Daniela Kry, Stephen Taylor, Paige Rong, John Zhang, Xiaodong Frank, Steven Followill, David Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: Artefacts caused by dental amalgam implants present a common challenge in computed tomography (CT) and therefore treatment planning dose calculations. The goal was to perform a quantitative image quality analysis of our Artifact Management for Proton Planning (AMPP) algorithm which used gantry tilts for managing metal artefacts on Head and Neck (HN) CT scans and major vendors’ commercial approaches. MATERIALS AND METHODS: Metal artefact reduction (MAR) algorithms were evaluated using an anthropomorphic phantom with a removable jaw for the acquisition of images with and without (baseline) metal artifacts. AMPP made use of two angled CT scans to generate one artifact-reduced image set. The MAR algorithms from four vendors were applied to the images with artefacts and the analysis was performed with respective baselines. Planar HU difference maps and volumetric HU differences were analyzed. RESULTS: AMPP algorithm outperformed all vendors’ commercial approaches in the elimination of artefacts in the oropharyngeal region, showing the lowest percent of pixels outside +− 20 HU criteria, 4%; whereas those in the MAR-corrected images ranged from 26% to 67%. In the region of interest within the affected slices, the commercial MAR algorithms showed inconsistent performance, whereas the AMPP algorithm performed consistently well throughout the phantom’s posterior region. CONCLUSIONS: A novel MAR algorithm was evaluated and compared to four commercial algorithms using an anthropomorphic phantom. Unanimously, the analysis showed the AMPP algorithm outperformed vendors’ commercial approaches, showing the potential to be broadly implemented, improve visualizations in patient anatomy and provide accurate HU information. Elsevier 2021-02-21 /pmc/articles/PMC8058027/ /pubmed/33898789 http://dx.doi.org/10.1016/j.phro.2021.01.007 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research Article
Branco, Daniela
Kry, Stephen
Taylor, Paige
Rong, John
Zhang, Xiaodong
Frank, Steven
Followill, David
Evaluation of image quality of a novel computed tomography metal artifact management technique on an anthropomorphic head and neck phantom
title Evaluation of image quality of a novel computed tomography metal artifact management technique on an anthropomorphic head and neck phantom
title_full Evaluation of image quality of a novel computed tomography metal artifact management technique on an anthropomorphic head and neck phantom
title_fullStr Evaluation of image quality of a novel computed tomography metal artifact management technique on an anthropomorphic head and neck phantom
title_full_unstemmed Evaluation of image quality of a novel computed tomography metal artifact management technique on an anthropomorphic head and neck phantom
title_short Evaluation of image quality of a novel computed tomography metal artifact management technique on an anthropomorphic head and neck phantom
title_sort evaluation of image quality of a novel computed tomography metal artifact management technique on an anthropomorphic head and neck phantom
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8058027/
https://www.ncbi.nlm.nih.gov/pubmed/33898789
http://dx.doi.org/10.1016/j.phro.2021.01.007
work_keys_str_mv AT brancodaniela evaluationofimagequalityofanovelcomputedtomographymetalartifactmanagementtechniqueonananthropomorphicheadandneckphantom
AT krystephen evaluationofimagequalityofanovelcomputedtomographymetalartifactmanagementtechniqueonananthropomorphicheadandneckphantom
AT taylorpaige evaluationofimagequalityofanovelcomputedtomographymetalartifactmanagementtechniqueonananthropomorphicheadandneckphantom
AT rongjohn evaluationofimagequalityofanovelcomputedtomographymetalartifactmanagementtechniqueonananthropomorphicheadandneckphantom
AT zhangxiaodong evaluationofimagequalityofanovelcomputedtomographymetalartifactmanagementtechniqueonananthropomorphicheadandneckphantom
AT franksteven evaluationofimagequalityofanovelcomputedtomographymetalartifactmanagementtechniqueonananthropomorphicheadandneckphantom
AT followilldavid evaluationofimagequalityofanovelcomputedtomographymetalartifactmanagementtechniqueonananthropomorphicheadandneckphantom