Cargando…

Skeletal and dental changes induced by the Flip-Lock Herbst appliance in the treatment of Angle’s class II division 1 malocclusion during active growth period: A preliminary study

Background. The Flip-Lock Herbst (TP Orthodontics Inc.) is a fixed functional appliance, a variant of the Herbst appliance, introduced by Miller. It is claimed to have better patient tolerance due to its increased freedom for the mandible’s lateral movements. There have been no studies on the flip l...

Descripción completa

Detalles Bibliográficos
Autores principales: Iyer, Sushmitha R, Premkumar, Sridhar, Muruganandam, Mangaleswari
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tabriz University of Medical Sciences 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8058159/
https://www.ncbi.nlm.nih.gov/pubmed/33927843
http://dx.doi.org/10.34172/joddd.2021.011
_version_ 1783680974563835904
author Iyer, Sushmitha R
Premkumar, Sridhar
Muruganandam, Mangaleswari
author_facet Iyer, Sushmitha R
Premkumar, Sridhar
Muruganandam, Mangaleswari
author_sort Iyer, Sushmitha R
collection PubMed
description Background. The Flip-Lock Herbst (TP Orthodontics Inc.) is a fixed functional appliance, a variant of the Herbst appliance, introduced by Miller. It is claimed to have better patient tolerance due to its increased freedom for the mandible’s lateral movements. There have been no studies on the flip lock Herbst till date. This study was undertaken to assess the efficiency of the Flip-Lock Herbst appliance in correcting Angle’s class II division 1 malocclusion. Methods. Eight subjects in their active growth period with class II division 1 malocclusion due to a retrognathic mandible were included in the study. Standardized lateral cephalometric radiographs were used to evaluate skeletal and dental changes with the SO analysis. Paired samples t-test was used to assess statistical significance. Results. Statistically significant increases in mandibular length (pg/OLp) and effective mandibular length (ar/OLp + pg/OLp) were observed. There was a significant maxillary restraining effect. Dental effects were significant and exhibited class II correction features except for the position of lower incisors within the mandible (ii/OLp - pg/OLp). Skeletal changes accounted for 61% and dental changes for 39% of the total treatment for molar correction. For overjet correction, skeletal changes contributed to 63% and dental changes to 37% of the total treatment. Conclusion. The Flip-Lock Herbst appliance was efficient in correcting Angle’s class II division 1 malocclusion due to a retrognathic mandible. Both skeletal and dental changes were evident, with the former predominating (60:40).
format Online
Article
Text
id pubmed-8058159
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Tabriz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-80581592021-04-28 Skeletal and dental changes induced by the Flip-Lock Herbst appliance in the treatment of Angle’s class II division 1 malocclusion during active growth period: A preliminary study Iyer, Sushmitha R Premkumar, Sridhar Muruganandam, Mangaleswari J Dent Res Dent Clin Dent Prospects Original Article Background. The Flip-Lock Herbst (TP Orthodontics Inc.) is a fixed functional appliance, a variant of the Herbst appliance, introduced by Miller. It is claimed to have better patient tolerance due to its increased freedom for the mandible’s lateral movements. There have been no studies on the flip lock Herbst till date. This study was undertaken to assess the efficiency of the Flip-Lock Herbst appliance in correcting Angle’s class II division 1 malocclusion. Methods. Eight subjects in their active growth period with class II division 1 malocclusion due to a retrognathic mandible were included in the study. Standardized lateral cephalometric radiographs were used to evaluate skeletal and dental changes with the SO analysis. Paired samples t-test was used to assess statistical significance. Results. Statistically significant increases in mandibular length (pg/OLp) and effective mandibular length (ar/OLp + pg/OLp) were observed. There was a significant maxillary restraining effect. Dental effects were significant and exhibited class II correction features except for the position of lower incisors within the mandible (ii/OLp - pg/OLp). Skeletal changes accounted for 61% and dental changes for 39% of the total treatment for molar correction. For overjet correction, skeletal changes contributed to 63% and dental changes to 37% of the total treatment. Conclusion. The Flip-Lock Herbst appliance was efficient in correcting Angle’s class II division 1 malocclusion due to a retrognathic mandible. Both skeletal and dental changes were evident, with the former predominating (60:40). Tabriz University of Medical Sciences 2021 2021-02-13 /pmc/articles/PMC8058159/ /pubmed/33927843 http://dx.doi.org/10.34172/joddd.2021.011 Text en © 2021 The Author(s). https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Iyer, Sushmitha R
Premkumar, Sridhar
Muruganandam, Mangaleswari
Skeletal and dental changes induced by the Flip-Lock Herbst appliance in the treatment of Angle’s class II division 1 malocclusion during active growth period: A preliminary study
title Skeletal and dental changes induced by the Flip-Lock Herbst appliance in the treatment of Angle’s class II division 1 malocclusion during active growth period: A preliminary study
title_full Skeletal and dental changes induced by the Flip-Lock Herbst appliance in the treatment of Angle’s class II division 1 malocclusion during active growth period: A preliminary study
title_fullStr Skeletal and dental changes induced by the Flip-Lock Herbst appliance in the treatment of Angle’s class II division 1 malocclusion during active growth period: A preliminary study
title_full_unstemmed Skeletal and dental changes induced by the Flip-Lock Herbst appliance in the treatment of Angle’s class II division 1 malocclusion during active growth period: A preliminary study
title_short Skeletal and dental changes induced by the Flip-Lock Herbst appliance in the treatment of Angle’s class II division 1 malocclusion during active growth period: A preliminary study
title_sort skeletal and dental changes induced by the flip-lock herbst appliance in the treatment of angle’s class ii division 1 malocclusion during active growth period: a preliminary study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8058159/
https://www.ncbi.nlm.nih.gov/pubmed/33927843
http://dx.doi.org/10.34172/joddd.2021.011
work_keys_str_mv AT iyersushmithar skeletalanddentalchangesinducedbythefliplockherbstapplianceinthetreatmentofanglesclassiidivision1malocclusionduringactivegrowthperiodapreliminarystudy
AT premkumarsridhar skeletalanddentalchangesinducedbythefliplockherbstapplianceinthetreatmentofanglesclassiidivision1malocclusionduringactivegrowthperiodapreliminarystudy
AT muruganandammangaleswari skeletalanddentalchangesinducedbythefliplockherbstapplianceinthetreatmentofanglesclassiidivision1malocclusionduringactivegrowthperiodapreliminarystudy