Cargando…
Vestibular Organ and Cochlear Implantation–A Synchrotron and Micro-CT Study
Background: Reports vary on the incidence of vestibular dysfunction and dizziness in patients following cochlear implantation (CI). Disequilibrium may be caused by surgery at the cochlear base, leading to functional disturbances of the vestibular receptors and endolymphatic duct system (EDS) which a...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8058461/ https://www.ncbi.nlm.nih.gov/pubmed/33897611 http://dx.doi.org/10.3389/fneur.2021.663722 |
_version_ | 1783681018573619200 |
---|---|
author | Li, Hao Schart-Moren, Nadine Rajan, Gunesh Shaw, Jeremy Rohani, Seyed Alireza Atturo, Francesca Ladak, Hanif M. Rask-Andersen, Helge Agrawal, Sumit |
author_facet | Li, Hao Schart-Moren, Nadine Rajan, Gunesh Shaw, Jeremy Rohani, Seyed Alireza Atturo, Francesca Ladak, Hanif M. Rask-Andersen, Helge Agrawal, Sumit |
author_sort | Li, Hao |
collection | PubMed |
description | Background: Reports vary on the incidence of vestibular dysfunction and dizziness in patients following cochlear implantation (CI). Disequilibrium may be caused by surgery at the cochlear base, leading to functional disturbances of the vestibular receptors and endolymphatic duct system (EDS) which are located nearby. Here, we analyzed the three-dimensional (3D) anatomy of this region, aiming to optimize surgical approaches to limit damage to the vestibular organ. Material and Methods: A total of 22 fresh-frozen human temporal bones underwent synchrotron radiation phase-contrast imaging (SR-PCI). One temporal bone underwent micro-computed tomography (micro-CT) after fixation and staining with Lugol's iodine solution (I(2)KI) to increase tissue contrast. We used volume-rendering software to create 3D reconstructions and tissue segmentation that allowed precise assessment of anatomical relationships and topography. Macerated human ears belonging to the Uppsala collection were also used. Drilling and insertion of CI electrodes was performed with metric analyses of different trajectories. Results and Conclusions: SR-PCI and micro-CT imaging demonstrated the complex 3D anatomy of the basal region of the human cochlea, vestibular apparatus, and EDS. Drilling of a cochleostomy may disturb vestibular organ function by injuring the endolymphatic space and disrupting fluid barriers. The saccule is at particular risk due to its proximity to the surgical area and may explain immediate and long-term post-operative vertigo. Round window insertion may be less traumatic to the inner ear, however it may affect the vestibular receptors. |
format | Online Article Text |
id | pubmed-8058461 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-80584612021-04-22 Vestibular Organ and Cochlear Implantation–A Synchrotron and Micro-CT Study Li, Hao Schart-Moren, Nadine Rajan, Gunesh Shaw, Jeremy Rohani, Seyed Alireza Atturo, Francesca Ladak, Hanif M. Rask-Andersen, Helge Agrawal, Sumit Front Neurol Neurology Background: Reports vary on the incidence of vestibular dysfunction and dizziness in patients following cochlear implantation (CI). Disequilibrium may be caused by surgery at the cochlear base, leading to functional disturbances of the vestibular receptors and endolymphatic duct system (EDS) which are located nearby. Here, we analyzed the three-dimensional (3D) anatomy of this region, aiming to optimize surgical approaches to limit damage to the vestibular organ. Material and Methods: A total of 22 fresh-frozen human temporal bones underwent synchrotron radiation phase-contrast imaging (SR-PCI). One temporal bone underwent micro-computed tomography (micro-CT) after fixation and staining with Lugol's iodine solution (I(2)KI) to increase tissue contrast. We used volume-rendering software to create 3D reconstructions and tissue segmentation that allowed precise assessment of anatomical relationships and topography. Macerated human ears belonging to the Uppsala collection were also used. Drilling and insertion of CI electrodes was performed with metric analyses of different trajectories. Results and Conclusions: SR-PCI and micro-CT imaging demonstrated the complex 3D anatomy of the basal region of the human cochlea, vestibular apparatus, and EDS. Drilling of a cochleostomy may disturb vestibular organ function by injuring the endolymphatic space and disrupting fluid barriers. The saccule is at particular risk due to its proximity to the surgical area and may explain immediate and long-term post-operative vertigo. Round window insertion may be less traumatic to the inner ear, however it may affect the vestibular receptors. Frontiers Media S.A. 2021-04-07 /pmc/articles/PMC8058461/ /pubmed/33897611 http://dx.doi.org/10.3389/fneur.2021.663722 Text en Copyright © 2021 Li, Schart-Moren, Rajan, Shaw, Rohani, Atturo, Ladak, Rask-Andersen and Agrawal. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neurology Li, Hao Schart-Moren, Nadine Rajan, Gunesh Shaw, Jeremy Rohani, Seyed Alireza Atturo, Francesca Ladak, Hanif M. Rask-Andersen, Helge Agrawal, Sumit Vestibular Organ and Cochlear Implantation–A Synchrotron and Micro-CT Study |
title | Vestibular Organ and Cochlear Implantation–A Synchrotron and Micro-CT Study |
title_full | Vestibular Organ and Cochlear Implantation–A Synchrotron and Micro-CT Study |
title_fullStr | Vestibular Organ and Cochlear Implantation–A Synchrotron and Micro-CT Study |
title_full_unstemmed | Vestibular Organ and Cochlear Implantation–A Synchrotron and Micro-CT Study |
title_short | Vestibular Organ and Cochlear Implantation–A Synchrotron and Micro-CT Study |
title_sort | vestibular organ and cochlear implantation–a synchrotron and micro-ct study |
topic | Neurology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8058461/ https://www.ncbi.nlm.nih.gov/pubmed/33897611 http://dx.doi.org/10.3389/fneur.2021.663722 |
work_keys_str_mv | AT lihao vestibularorganandcochlearimplantationasynchrotronandmicroctstudy AT schartmorennadine vestibularorganandcochlearimplantationasynchrotronandmicroctstudy AT rajangunesh vestibularorganandcochlearimplantationasynchrotronandmicroctstudy AT shawjeremy vestibularorganandcochlearimplantationasynchrotronandmicroctstudy AT rohaniseyedalireza vestibularorganandcochlearimplantationasynchrotronandmicroctstudy AT atturofrancesca vestibularorganandcochlearimplantationasynchrotronandmicroctstudy AT ladakhanifm vestibularorganandcochlearimplantationasynchrotronandmicroctstudy AT raskandersenhelge vestibularorganandcochlearimplantationasynchrotronandmicroctstudy AT agrawalsumit vestibularorganandcochlearimplantationasynchrotronandmicroctstudy |