Cargando…

Biomechanical sensing of in vivo magnetic nanoparticle hyperthermia-treated melanoma using magnetomotive optical coherence elastography

Rationale: Magnetic nanoparticle hyperthermia (MH) therapy is capable of thermally damaging tumor cells, yet a biomechanically-sensitive monitoring method for the applied thermal dosage has not been established. Biomechanical changes to tissue are known indicators for tumor diagnosis due to its asso...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Pin-Chieh, Chaney, Eric J., Aksamitiene, Edita, Barkalifa, Ronit, Spillman, Darold R., Bogan, Bethany J., Boppart, Stephen A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Ivyspring International Publisher 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8058715/
https://www.ncbi.nlm.nih.gov/pubmed/33897871
http://dx.doi.org/10.7150/thno.55333
_version_ 1783681065539338240
author Huang, Pin-Chieh
Chaney, Eric J.
Aksamitiene, Edita
Barkalifa, Ronit
Spillman, Darold R.
Bogan, Bethany J.
Boppart, Stephen A.
author_facet Huang, Pin-Chieh
Chaney, Eric J.
Aksamitiene, Edita
Barkalifa, Ronit
Spillman, Darold R.
Bogan, Bethany J.
Boppart, Stephen A.
author_sort Huang, Pin-Chieh
collection PubMed
description Rationale: Magnetic nanoparticle hyperthermia (MH) therapy is capable of thermally damaging tumor cells, yet a biomechanically-sensitive monitoring method for the applied thermal dosage has not been established. Biomechanical changes to tissue are known indicators for tumor diagnosis due to its association with the structural organization and composition of tissues at the cellular and molecular level. Here, by exploiting the theranostic functionality of magnetic nanoparticles (MNPs), we aim to explore the potential of using stiffness-based metrics that reveal the intrinsic biophysical changes of in vivo melanoma tumors after MH therapy. Methods: A total of 14 melanoma-bearing mice were intratumorally injected with dextran-coated MNPs, enabling MH treatment upon the application of an alternating magnetic field (AMF) at 64.7 kHz. The presence of the MNP heating sources was detected by magnetomotive optical coherence tomography (MM-OCT). For the first time, the elasticity alterations of the hyperthermia-treated, MNP-laden, in vivo tumors were also measured with magnetomotive optical coherence elastography (MM-OCE), based on the mechanical resonant frequency detected. To investigate the correlation between stiffness changes and the intrinsic biological changes, histopathology was performed on the excised tumor after the in vivo measurements. Results: Distinct shifts in mechanical resonant frequency were observed only in the MH-treated group, suggesting a heat-induced stiffness change in the melanoma tumor. Moreover, tumor cellularity, protein conformation, and temperature rise all play a role in tumor stiffness changes after MH treatment. With low cellularity, tumor softens after MH even with low temperature elevation. In contrast, with high cellularity, tumor softening occurs only with a low temperature rise, which is potentially due to protein unfolding, whereas tumor stiffening was seen with a higher temperature rise, likely due to protein denaturation. Conclusions: This study exploits the theranostic functionality of MNPs and investigates the MH-induced stiffness change on in vivo melanoma-bearing mice with MM-OCT and MM-OCE for the first time. It was discovered that the elasticity alteration of the melanoma tumor after MH treatment depends on both thermal dosage and the morphological features of the tumor. In summary, changes in tissue-level elasticity can potentially be a physically and physiologically meaningful metric and integrative therapeutic marker for MH treatment, while MM-OCE can be a suitable dosimetry technique.
format Online
Article
Text
id pubmed-8058715
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Ivyspring International Publisher
record_format MEDLINE/PubMed
spelling pubmed-80587152021-04-23 Biomechanical sensing of in vivo magnetic nanoparticle hyperthermia-treated melanoma using magnetomotive optical coherence elastography Huang, Pin-Chieh Chaney, Eric J. Aksamitiene, Edita Barkalifa, Ronit Spillman, Darold R. Bogan, Bethany J. Boppart, Stephen A. Theranostics Research Paper Rationale: Magnetic nanoparticle hyperthermia (MH) therapy is capable of thermally damaging tumor cells, yet a biomechanically-sensitive monitoring method for the applied thermal dosage has not been established. Biomechanical changes to tissue are known indicators for tumor diagnosis due to its association with the structural organization and composition of tissues at the cellular and molecular level. Here, by exploiting the theranostic functionality of magnetic nanoparticles (MNPs), we aim to explore the potential of using stiffness-based metrics that reveal the intrinsic biophysical changes of in vivo melanoma tumors after MH therapy. Methods: A total of 14 melanoma-bearing mice were intratumorally injected with dextran-coated MNPs, enabling MH treatment upon the application of an alternating magnetic field (AMF) at 64.7 kHz. The presence of the MNP heating sources was detected by magnetomotive optical coherence tomography (MM-OCT). For the first time, the elasticity alterations of the hyperthermia-treated, MNP-laden, in vivo tumors were also measured with magnetomotive optical coherence elastography (MM-OCE), based on the mechanical resonant frequency detected. To investigate the correlation between stiffness changes and the intrinsic biological changes, histopathology was performed on the excised tumor after the in vivo measurements. Results: Distinct shifts in mechanical resonant frequency were observed only in the MH-treated group, suggesting a heat-induced stiffness change in the melanoma tumor. Moreover, tumor cellularity, protein conformation, and temperature rise all play a role in tumor stiffness changes after MH treatment. With low cellularity, tumor softens after MH even with low temperature elevation. In contrast, with high cellularity, tumor softening occurs only with a low temperature rise, which is potentially due to protein unfolding, whereas tumor stiffening was seen with a higher temperature rise, likely due to protein denaturation. Conclusions: This study exploits the theranostic functionality of MNPs and investigates the MH-induced stiffness change on in vivo melanoma-bearing mice with MM-OCT and MM-OCE for the first time. It was discovered that the elasticity alteration of the melanoma tumor after MH treatment depends on both thermal dosage and the morphological features of the tumor. In summary, changes in tissue-level elasticity can potentially be a physically and physiologically meaningful metric and integrative therapeutic marker for MH treatment, while MM-OCE can be a suitable dosimetry technique. Ivyspring International Publisher 2021-03-23 /pmc/articles/PMC8058715/ /pubmed/33897871 http://dx.doi.org/10.7150/thno.55333 Text en © The author(s) https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/). See http://ivyspring.com/terms for full terms and conditions.
spellingShingle Research Paper
Huang, Pin-Chieh
Chaney, Eric J.
Aksamitiene, Edita
Barkalifa, Ronit
Spillman, Darold R.
Bogan, Bethany J.
Boppart, Stephen A.
Biomechanical sensing of in vivo magnetic nanoparticle hyperthermia-treated melanoma using magnetomotive optical coherence elastography
title Biomechanical sensing of in vivo magnetic nanoparticle hyperthermia-treated melanoma using magnetomotive optical coherence elastography
title_full Biomechanical sensing of in vivo magnetic nanoparticle hyperthermia-treated melanoma using magnetomotive optical coherence elastography
title_fullStr Biomechanical sensing of in vivo magnetic nanoparticle hyperthermia-treated melanoma using magnetomotive optical coherence elastography
title_full_unstemmed Biomechanical sensing of in vivo magnetic nanoparticle hyperthermia-treated melanoma using magnetomotive optical coherence elastography
title_short Biomechanical sensing of in vivo magnetic nanoparticle hyperthermia-treated melanoma using magnetomotive optical coherence elastography
title_sort biomechanical sensing of in vivo magnetic nanoparticle hyperthermia-treated melanoma using magnetomotive optical coherence elastography
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8058715/
https://www.ncbi.nlm.nih.gov/pubmed/33897871
http://dx.doi.org/10.7150/thno.55333
work_keys_str_mv AT huangpinchieh biomechanicalsensingofinvivomagneticnanoparticlehyperthermiatreatedmelanomausingmagnetomotiveopticalcoherenceelastography
AT chaneyericj biomechanicalsensingofinvivomagneticnanoparticlehyperthermiatreatedmelanomausingmagnetomotiveopticalcoherenceelastography
AT aksamitieneedita biomechanicalsensingofinvivomagneticnanoparticlehyperthermiatreatedmelanomausingmagnetomotiveopticalcoherenceelastography
AT barkalifaronit biomechanicalsensingofinvivomagneticnanoparticlehyperthermiatreatedmelanomausingmagnetomotiveopticalcoherenceelastography
AT spillmandaroldr biomechanicalsensingofinvivomagneticnanoparticlehyperthermiatreatedmelanomausingmagnetomotiveopticalcoherenceelastography
AT boganbethanyj biomechanicalsensingofinvivomagneticnanoparticlehyperthermiatreatedmelanomausingmagnetomotiveopticalcoherenceelastography
AT boppartstephena biomechanicalsensingofinvivomagneticnanoparticlehyperthermiatreatedmelanomausingmagnetomotiveopticalcoherenceelastography