Cargando…

Repair Integrity and Functional Outcomes Between Knot-Tying and Knotless Suture-Bridge Arthroscopic Rotator Cuff Repair: A Prospective Randomized Clinical Trial

BACKGROUND: Knot-tying suture-bridge (SB) rotator cuff repair may compromise the vascularity of the repaired tendon, causing tendon strangulation and medial repair failure. The knotless SB repair technique has been proposed to overcome this possibility and decrease retear rates. PURPOSE: To compare...

Descripción completa

Detalles Bibliográficos
Autores principales: Şahin, Koray, Şentürk, Fatih, Ersin, Mehmet, Arzu, Ufuk, Chodza, Mechmet, Erşen, Ali
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8058806/
https://www.ncbi.nlm.nih.gov/pubmed/33954223
http://dx.doi.org/10.1177/23259671211002482
_version_ 1783681085561896960
author Şahin, Koray
Şentürk, Fatih
Ersin, Mehmet
Arzu, Ufuk
Chodza, Mechmet
Erşen, Ali
author_facet Şahin, Koray
Şentürk, Fatih
Ersin, Mehmet
Arzu, Ufuk
Chodza, Mechmet
Erşen, Ali
author_sort Şahin, Koray
collection PubMed
description BACKGROUND: Knot-tying suture-bridge (SB) rotator cuff repair may compromise the vascularity of the repaired tendon, causing tendon strangulation and medial repair failure. The knotless SB repair technique has been proposed to overcome this possibility and decrease retear rates. PURPOSE: To compare clinical and structural outcomes and retear patterns between the knot-tying and knotless SB techniques. We hypothesized that the knotless technique would result in lower retear rates owing to the preservation of intratendinous vascularity. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: A total of 104 patients with full-thickness rotator cuff tears were randomly and prospectively allocated to undergo knot-tying (group 1) or knotless (group 2) SB repair. Clinical outcome measures included range of motion, the visual analog scale (VAS) for pain, and the Constant score for function. Repair integrity was evaluated on magnetic resonance imaging scans using the Sugaya classification. Retears were also classified according to their pattern as type 1 (lateral) or type 2 (medial). RESULTS: Overall, 88 patients (group 1: n = 42 [mean ± SD age, 54.3 ± 9.8 years]; group 2: n = 46 [mean ± SD age, 55.8 ± 8.2 years]) were included in the final analysis. The mean ± SD follow-up period was 25.4 ± 8.3 and 23.3 ± 7.2 months for groups 1 and 2, respectively. From preoperatively to postoperatively, the mean VAS pain score improved significantly in both groups (group 1: from 7.4 ± 1.7 to 1.0 ± 1.7; group 2: from 7.1 ± 1.9 to 1.3 ± 2.0; P < .0001 for both), as did the mean ± SD Constant score (group 1: from 51.7 ± 13.4 to 86.0 ± 11.5; group 2: from 49.4 ± 18.4 to 87.2 ± 14.8; P < .0001 for both). There was no significant difference between the groups for the postoperative VAS or Constant score. The retear rate was not significantly different between the groups (19.0% [8/42] in group 1 and 28.3% [13/46] in group 2; P > .05). There was a significant difference in the type 2 failure rate (75.0% [6/8] in group 1 and 23.1% [3/13] in group 2; P = .03). CONCLUSION: Both techniques showed excellent improvement and comparable clinical outcomes, and there was no significant difference in retear rates. Consistent with previously published data, the type 2 failure rate was significantly higher with the knot-tying technique. REGISTRATION: NCT03982108 (ClinicalTrials.gov identifier).
format Online
Article
Text
id pubmed-8058806
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-80588062021-05-04 Repair Integrity and Functional Outcomes Between Knot-Tying and Knotless Suture-Bridge Arthroscopic Rotator Cuff Repair: A Prospective Randomized Clinical Trial Şahin, Koray Şentürk, Fatih Ersin, Mehmet Arzu, Ufuk Chodza, Mechmet Erşen, Ali Orthop J Sports Med Article BACKGROUND: Knot-tying suture-bridge (SB) rotator cuff repair may compromise the vascularity of the repaired tendon, causing tendon strangulation and medial repair failure. The knotless SB repair technique has been proposed to overcome this possibility and decrease retear rates. PURPOSE: To compare clinical and structural outcomes and retear patterns between the knot-tying and knotless SB techniques. We hypothesized that the knotless technique would result in lower retear rates owing to the preservation of intratendinous vascularity. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: A total of 104 patients with full-thickness rotator cuff tears were randomly and prospectively allocated to undergo knot-tying (group 1) or knotless (group 2) SB repair. Clinical outcome measures included range of motion, the visual analog scale (VAS) for pain, and the Constant score for function. Repair integrity was evaluated on magnetic resonance imaging scans using the Sugaya classification. Retears were also classified according to their pattern as type 1 (lateral) or type 2 (medial). RESULTS: Overall, 88 patients (group 1: n = 42 [mean ± SD age, 54.3 ± 9.8 years]; group 2: n = 46 [mean ± SD age, 55.8 ± 8.2 years]) were included in the final analysis. The mean ± SD follow-up period was 25.4 ± 8.3 and 23.3 ± 7.2 months for groups 1 and 2, respectively. From preoperatively to postoperatively, the mean VAS pain score improved significantly in both groups (group 1: from 7.4 ± 1.7 to 1.0 ± 1.7; group 2: from 7.1 ± 1.9 to 1.3 ± 2.0; P < .0001 for both), as did the mean ± SD Constant score (group 1: from 51.7 ± 13.4 to 86.0 ± 11.5; group 2: from 49.4 ± 18.4 to 87.2 ± 14.8; P < .0001 for both). There was no significant difference between the groups for the postoperative VAS or Constant score. The retear rate was not significantly different between the groups (19.0% [8/42] in group 1 and 28.3% [13/46] in group 2; P > .05). There was a significant difference in the type 2 failure rate (75.0% [6/8] in group 1 and 23.1% [3/13] in group 2; P = .03). CONCLUSION: Both techniques showed excellent improvement and comparable clinical outcomes, and there was no significant difference in retear rates. Consistent with previously published data, the type 2 failure rate was significantly higher with the knot-tying technique. REGISTRATION: NCT03982108 (ClinicalTrials.gov identifier). SAGE Publications 2021-04-19 /pmc/articles/PMC8058806/ /pubmed/33954223 http://dx.doi.org/10.1177/23259671211002482 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Şahin, Koray
Şentürk, Fatih
Ersin, Mehmet
Arzu, Ufuk
Chodza, Mechmet
Erşen, Ali
Repair Integrity and Functional Outcomes Between Knot-Tying and Knotless Suture-Bridge Arthroscopic Rotator Cuff Repair: A Prospective Randomized Clinical Trial
title Repair Integrity and Functional Outcomes Between Knot-Tying and Knotless Suture-Bridge Arthroscopic Rotator Cuff Repair: A Prospective Randomized Clinical Trial
title_full Repair Integrity and Functional Outcomes Between Knot-Tying and Knotless Suture-Bridge Arthroscopic Rotator Cuff Repair: A Prospective Randomized Clinical Trial
title_fullStr Repair Integrity and Functional Outcomes Between Knot-Tying and Knotless Suture-Bridge Arthroscopic Rotator Cuff Repair: A Prospective Randomized Clinical Trial
title_full_unstemmed Repair Integrity and Functional Outcomes Between Knot-Tying and Knotless Suture-Bridge Arthroscopic Rotator Cuff Repair: A Prospective Randomized Clinical Trial
title_short Repair Integrity and Functional Outcomes Between Knot-Tying and Knotless Suture-Bridge Arthroscopic Rotator Cuff Repair: A Prospective Randomized Clinical Trial
title_sort repair integrity and functional outcomes between knot-tying and knotless suture-bridge arthroscopic rotator cuff repair: a prospective randomized clinical trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8058806/
https://www.ncbi.nlm.nih.gov/pubmed/33954223
http://dx.doi.org/10.1177/23259671211002482
work_keys_str_mv AT sahinkoray repairintegrityandfunctionaloutcomesbetweenknottyingandknotlesssuturebridgearthroscopicrotatorcuffrepairaprospectiverandomizedclinicaltrial
AT senturkfatih repairintegrityandfunctionaloutcomesbetweenknottyingandknotlesssuturebridgearthroscopicrotatorcuffrepairaprospectiverandomizedclinicaltrial
AT ersinmehmet repairintegrityandfunctionaloutcomesbetweenknottyingandknotlesssuturebridgearthroscopicrotatorcuffrepairaprospectiverandomizedclinicaltrial
AT arzuufuk repairintegrityandfunctionaloutcomesbetweenknottyingandknotlesssuturebridgearthroscopicrotatorcuffrepairaprospectiverandomizedclinicaltrial
AT chodzamechmet repairintegrityandfunctionaloutcomesbetweenknottyingandknotlesssuturebridgearthroscopicrotatorcuffrepairaprospectiverandomizedclinicaltrial
AT ersenali repairintegrityandfunctionaloutcomesbetweenknottyingandknotlesssuturebridgearthroscopicrotatorcuffrepairaprospectiverandomizedclinicaltrial