Cargando…
Identification of heart rate dynamics during treadmill exercise: comparison of first- and second-order models
BACKGROUND: Characterisation of heart rate (HR) dynamics and their dependence on exercise intensity provides a basis for feedback design of automatic HR control systems. This work aimed to investigate whether the second-order models with separate Phase I and Phase II components of HR response can ac...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8059023/ https://www.ncbi.nlm.nih.gov/pubmed/33882920 http://dx.doi.org/10.1186/s12938-021-00875-7 |
Sumario: | BACKGROUND: Characterisation of heart rate (HR) dynamics and their dependence on exercise intensity provides a basis for feedback design of automatic HR control systems. This work aimed to investigate whether the second-order models with separate Phase I and Phase II components of HR response can achieve better fitting performance compared to the first-order models that do not delineate the two phases. METHODS: Eleven participants each performed two open-loop identification tests while running at moderate-to-vigorous intensity on a treadmill. Treadmill speed was changed as a pseudo-random binary sequence (PRBS) to excite both the Phase I and Phase II components. A counterbalanced cross-validation approach was implemented for model parameter estimation and validation. RESULTS: Comparison of validation outcomes for 22 pairs of first- and second-order models showed that root-mean-square error (RMSE) was significantly lower and fit (normalised RMSE) significantly higher for the second-order models: RMSE was 2.07 bpm ± 0.36 bpm vs. 2.27 bpm ± 0.36 bpm (bpm = beats per min), second order vs. first order, with [Formula: see text] ; fit was [Formula: see text] % vs. [Formula: see text] %, [Formula: see text] . CONCLUSION: Second-order models give significantly better goodness-of-fit than first-order models, likely due to the inclusion of both Phase I and Phase II components of heart rate response. Future work should investigate alternative parameterisations of the PRBS excitation, and whether feedback controllers calculated using second-order models give better performance than those based on first-order models. |
---|