Cargando…
New stent for transapical mitral valve replacement in acute swine experiment
BACKGROUND: Many patients with mitral regurgitation are denied open-heart surgery due to perceived high risk. Transcatheter mitral valve replacement is a therapeutic alternative for patients at high surgical risk. This study aimed to assess the feasibility of a new self-expanding valved stent for tr...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8059321/ https://www.ncbi.nlm.nih.gov/pubmed/33882974 http://dx.doi.org/10.1186/s13019-021-01483-1 |
_version_ | 1783681177461194752 |
---|---|
author | Zou, Yu Teng, Peng Ma, Liang |
author_facet | Zou, Yu Teng, Peng Ma, Liang |
author_sort | Zou, Yu |
collection | PubMed |
description | BACKGROUND: Many patients with mitral regurgitation are denied open-heart surgery due to perceived high risk. Transcatheter mitral valve replacement is a therapeutic alternative for patients at high surgical risk. This study aimed to assess the feasibility of a new self-expanding valved stent for transcatheter mitral valve replacement via apex in an acute animal model. METHODS: Eight porcine experiments were performed in the acute study. A left thoracotomy was performed, and the new self-expanding transcatheter valved stent was deployed under fluoroscopic guidance in the native mitral annulus via apex. Hemodynamic data were recorded before and after implantation. Mitral annulus diameter and valve area were measured using echocardiography. Transvalvular and left ventricular outflow tract pressure gradients were measured using invasive methods. RESULTS: Seven animals underwent successful transapical mitral valve replacement; the implantation was unsuccessful in one animal. The mean procedure time, defined from placement to tightening of the purse-string suture, was 17.14 ± 7.86 min. Hemodynamic data before and after transapical mitral valve replacement showed no difference in statistical analysis. The mean diameter of the self-expanding device after implantation was 2.58 ± 1.04 cm; the mean functional area was 2.70 ± 0.26 cm(2). Trace-to-mild central and paravalvular leaks were detected in 7 valves. The mean pressure gradient across the self-expanding device was 2.00 ± 0.82 mmHg; the corresponding gradient across the LVOT was 3.28 ± 1.11 mmHg. Postmortem evaluation confirmed precise device positioning in 7 animals with no signs of LVOT obstruction. CONCLUSION: Transcatheter mitral replacement of the new valved stent was confirmed feasible in acute preclinical models. The new stent reveals optimal design parameters. |
format | Online Article Text |
id | pubmed-8059321 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-80593212021-04-22 New stent for transapical mitral valve replacement in acute swine experiment Zou, Yu Teng, Peng Ma, Liang J Cardiothorac Surg Research Article BACKGROUND: Many patients with mitral regurgitation are denied open-heart surgery due to perceived high risk. Transcatheter mitral valve replacement is a therapeutic alternative for patients at high surgical risk. This study aimed to assess the feasibility of a new self-expanding valved stent for transcatheter mitral valve replacement via apex in an acute animal model. METHODS: Eight porcine experiments were performed in the acute study. A left thoracotomy was performed, and the new self-expanding transcatheter valved stent was deployed under fluoroscopic guidance in the native mitral annulus via apex. Hemodynamic data were recorded before and after implantation. Mitral annulus diameter and valve area were measured using echocardiography. Transvalvular and left ventricular outflow tract pressure gradients were measured using invasive methods. RESULTS: Seven animals underwent successful transapical mitral valve replacement; the implantation was unsuccessful in one animal. The mean procedure time, defined from placement to tightening of the purse-string suture, was 17.14 ± 7.86 min. Hemodynamic data before and after transapical mitral valve replacement showed no difference in statistical analysis. The mean diameter of the self-expanding device after implantation was 2.58 ± 1.04 cm; the mean functional area was 2.70 ± 0.26 cm(2). Trace-to-mild central and paravalvular leaks were detected in 7 valves. The mean pressure gradient across the self-expanding device was 2.00 ± 0.82 mmHg; the corresponding gradient across the LVOT was 3.28 ± 1.11 mmHg. Postmortem evaluation confirmed precise device positioning in 7 animals with no signs of LVOT obstruction. CONCLUSION: Transcatheter mitral replacement of the new valved stent was confirmed feasible in acute preclinical models. The new stent reveals optimal design parameters. BioMed Central 2021-04-21 /pmc/articles/PMC8059321/ /pubmed/33882974 http://dx.doi.org/10.1186/s13019-021-01483-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Zou, Yu Teng, Peng Ma, Liang New stent for transapical mitral valve replacement in acute swine experiment |
title | New stent for transapical mitral valve replacement in acute swine experiment |
title_full | New stent for transapical mitral valve replacement in acute swine experiment |
title_fullStr | New stent for transapical mitral valve replacement in acute swine experiment |
title_full_unstemmed | New stent for transapical mitral valve replacement in acute swine experiment |
title_short | New stent for transapical mitral valve replacement in acute swine experiment |
title_sort | new stent for transapical mitral valve replacement in acute swine experiment |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8059321/ https://www.ncbi.nlm.nih.gov/pubmed/33882974 http://dx.doi.org/10.1186/s13019-021-01483-1 |
work_keys_str_mv | AT zouyu newstentfortransapicalmitralvalvereplacementinacuteswineexperiment AT tengpeng newstentfortransapicalmitralvalvereplacementinacuteswineexperiment AT maliang newstentfortransapicalmitralvalvereplacementinacuteswineexperiment |