Cargando…

Diagnostic Value of Pyruvate Kinase Isoenzyme Type M2 in Colon Cancer Proven with Colonoscopy

BACKGROUND: Colonoscopy is the gold standard for colon cancer screening; it is also associated with a high cost and complication. Proliferating cells, in particular tumor cells, express a dimeric isoenzyme of pyruvate kinase, termed M2 pyruvate kinase (M2-PK). The aim of this study was to determine...

Descripción completa

Detalles Bibliográficos
Autores principales: Kalantari, Hamid, Khodadoostan, Mahsa, Yaran, Majid, Tavakoli, Abdolrasoul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8059451/
https://www.ncbi.nlm.nih.gov/pubmed/33912492
http://dx.doi.org/10.4103/abr.abr_91_20
_version_ 1783681192005992448
author Kalantari, Hamid
Khodadoostan, Mahsa
Yaran, Majid
Tavakoli, Abdolrasoul
author_facet Kalantari, Hamid
Khodadoostan, Mahsa
Yaran, Majid
Tavakoli, Abdolrasoul
author_sort Kalantari, Hamid
collection PubMed
description BACKGROUND: Colonoscopy is the gold standard for colon cancer screening; it is also associated with a high cost and complication. Proliferating cells, in particular tumor cells, express a dimeric isoenzyme of pyruvate kinase, termed M2 pyruvate kinase (M2-PK). The aim of this study was to determine the diagnostic accuracy of fecal M2-PK for colon cancer. MATERIALS AND METHODS: Forty-nine patients with colon cancers and 49 healthy controls were selected consecutively among individuals undergoing screening colonoscopy for various indications. The diagnosis was confirmed by histology. M2-PK measurements were done by enzyme-linked immunosorbent assay of fecal occult blood test (FOBT) and immunological FOBT (IFOBT) according to the manufacturer's instructions. RESULTS: M2-PK > 9 (U/mL) was the best cutoff point in the detection of colon cancers. In this cutoff point, sensitivity and specificity were 87.8% and 91.8%, respectively, and accuracy was 89.8%. The sensitivity and specificity of IFOBT were 93.9% and 100%, respectively, and accuracy was 96.9%. The sensitivity and specificity of FOBT were 65.3% and 100%, respectively, and accuracy was 82.6%. CONCLUSION: IFOBT with high sensitivity and specificity and accuracy and low cost is the best fecal screening test. The current study suggests that fecal M2-PK can be used for high-risk colon cancer patients and negative IFOBT that refused colonoscopy as a precolonoscopy screening test.
format Online
Article
Text
id pubmed-8059451
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-80594512021-04-27 Diagnostic Value of Pyruvate Kinase Isoenzyme Type M2 in Colon Cancer Proven with Colonoscopy Kalantari, Hamid Khodadoostan, Mahsa Yaran, Majid Tavakoli, Abdolrasoul Adv Biomed Res Original Article BACKGROUND: Colonoscopy is the gold standard for colon cancer screening; it is also associated with a high cost and complication. Proliferating cells, in particular tumor cells, express a dimeric isoenzyme of pyruvate kinase, termed M2 pyruvate kinase (M2-PK). The aim of this study was to determine the diagnostic accuracy of fecal M2-PK for colon cancer. MATERIALS AND METHODS: Forty-nine patients with colon cancers and 49 healthy controls were selected consecutively among individuals undergoing screening colonoscopy for various indications. The diagnosis was confirmed by histology. M2-PK measurements were done by enzyme-linked immunosorbent assay of fecal occult blood test (FOBT) and immunological FOBT (IFOBT) according to the manufacturer's instructions. RESULTS: M2-PK > 9 (U/mL) was the best cutoff point in the detection of colon cancers. In this cutoff point, sensitivity and specificity were 87.8% and 91.8%, respectively, and accuracy was 89.8%. The sensitivity and specificity of IFOBT were 93.9% and 100%, respectively, and accuracy was 96.9%. The sensitivity and specificity of FOBT were 65.3% and 100%, respectively, and accuracy was 82.6%. CONCLUSION: IFOBT with high sensitivity and specificity and accuracy and low cost is the best fecal screening test. The current study suggests that fecal M2-PK can be used for high-risk colon cancer patients and negative IFOBT that refused colonoscopy as a precolonoscopy screening test. Wolters Kluwer - Medknow 2020-12-23 /pmc/articles/PMC8059451/ /pubmed/33912492 http://dx.doi.org/10.4103/abr.abr_91_20 Text en Copyright: © 2020 Advanced Biomedical Research https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kalantari, Hamid
Khodadoostan, Mahsa
Yaran, Majid
Tavakoli, Abdolrasoul
Diagnostic Value of Pyruvate Kinase Isoenzyme Type M2 in Colon Cancer Proven with Colonoscopy
title Diagnostic Value of Pyruvate Kinase Isoenzyme Type M2 in Colon Cancer Proven with Colonoscopy
title_full Diagnostic Value of Pyruvate Kinase Isoenzyme Type M2 in Colon Cancer Proven with Colonoscopy
title_fullStr Diagnostic Value of Pyruvate Kinase Isoenzyme Type M2 in Colon Cancer Proven with Colonoscopy
title_full_unstemmed Diagnostic Value of Pyruvate Kinase Isoenzyme Type M2 in Colon Cancer Proven with Colonoscopy
title_short Diagnostic Value of Pyruvate Kinase Isoenzyme Type M2 in Colon Cancer Proven with Colonoscopy
title_sort diagnostic value of pyruvate kinase isoenzyme type m2 in colon cancer proven with colonoscopy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8059451/
https://www.ncbi.nlm.nih.gov/pubmed/33912492
http://dx.doi.org/10.4103/abr.abr_91_20
work_keys_str_mv AT kalantarihamid diagnosticvalueofpyruvatekinaseisoenzymetypem2incoloncancerprovenwithcolonoscopy
AT khodadoostanmahsa diagnosticvalueofpyruvatekinaseisoenzymetypem2incoloncancerprovenwithcolonoscopy
AT yaranmajid diagnosticvalueofpyruvatekinaseisoenzymetypem2incoloncancerprovenwithcolonoscopy
AT tavakoliabdolrasoul diagnosticvalueofpyruvatekinaseisoenzymetypem2incoloncancerprovenwithcolonoscopy