Cargando…

T-staging of rectal cancer: Utility of single-shot turbo spin-echo diffusion-weighted imaging with T2-weighted images and fusion images

PURPOSE: The purpose of this study was to evaluate the usefulness of turbo spin-echo (TSE) DWI with fusion images in the T-staging compared with T2-weighted imaging (T2WI) alone and conventional echo-planner imaging (EPI) DWI. METHODS: In this prospective study, 4-mm-thick axial EPI-DWI, TSE-DWI, an...

Descripción completa

Detalles Bibliográficos
Autores principales: Ogawa, Masaki, Urano, Misugi, Takaishi, Taku, Kan, Hirohito, Arai, Nobuyuki, Takahashi, Hiroki, Hara, Masayasu, Saito, Miki, Shibamoto, Yuta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8059798/
https://www.ncbi.nlm.nih.gov/pubmed/33882087
http://dx.doi.org/10.1371/journal.pone.0249433
_version_ 1783681245615489024
author Ogawa, Masaki
Urano, Misugi
Takaishi, Taku
Kan, Hirohito
Arai, Nobuyuki
Takahashi, Hiroki
Hara, Masayasu
Saito, Miki
Shibamoto, Yuta
author_facet Ogawa, Masaki
Urano, Misugi
Takaishi, Taku
Kan, Hirohito
Arai, Nobuyuki
Takahashi, Hiroki
Hara, Masayasu
Saito, Miki
Shibamoto, Yuta
author_sort Ogawa, Masaki
collection PubMed
description PURPOSE: The purpose of this study was to evaluate the usefulness of turbo spin-echo (TSE) DWI with fusion images in the T-staging compared with T2-weighted imaging (T2WI) alone and conventional echo-planner imaging (EPI) DWI. METHODS: In this prospective study, 4-mm-thick axial EPI-DWI, TSE-DWI, and T2WI were performed with the same slice locations for 20 patients with rectal cancer. Fusion images of DWI and T2WI were created for both EPI-DWI and TSE-DWI. Ten readers independently diagnosed the T-stages and scored the degree of confidence referring to T2WI alone and then to DWI, T2WI, and fusion images (DWI+T2WI) for each EPI-DWI and TSE-DWI. Visual score assessments of image quality were performed for each DWI. RESULTS: Inter-observer agreement of T-staging for 10 readers was slight on T2WI alone but fair on EPI-DWI+T2WI and excellent on TSE-DWI+T2WI images. No readers gave higher confidence scores for T2WI compared to EPI/TSE-DWI+T2WI and for EPI-DWI+T2WI compared to TSE-DWI+T2WI. In seven pathologically-proven cases, poor, poor to slight, and fair to perfect agreements with the pathological T-stage were observed with T2WI alone, EPI-DWI+T2WI, and TSE-DWI+T2WI, respectively. All readers gave higher scores regarding image distortion and lower scores regarding image noise for TSE-DWI compared to EPI-DWI. For DWI utility, higher scores were assigned for TSE-DWI compared to EPI-DWI in 7 readers and there were no significant differences in the other 3 readers. CONCLUSION: TSE-DWI images might be more appropriate for image fusion with T2WI and rectal cancer T-staging compared with EPI-DWI and T2WI alone.
format Online
Article
Text
id pubmed-8059798
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-80597982021-05-04 T-staging of rectal cancer: Utility of single-shot turbo spin-echo diffusion-weighted imaging with T2-weighted images and fusion images Ogawa, Masaki Urano, Misugi Takaishi, Taku Kan, Hirohito Arai, Nobuyuki Takahashi, Hiroki Hara, Masayasu Saito, Miki Shibamoto, Yuta PLoS One Research Article PURPOSE: The purpose of this study was to evaluate the usefulness of turbo spin-echo (TSE) DWI with fusion images in the T-staging compared with T2-weighted imaging (T2WI) alone and conventional echo-planner imaging (EPI) DWI. METHODS: In this prospective study, 4-mm-thick axial EPI-DWI, TSE-DWI, and T2WI were performed with the same slice locations for 20 patients with rectal cancer. Fusion images of DWI and T2WI were created for both EPI-DWI and TSE-DWI. Ten readers independently diagnosed the T-stages and scored the degree of confidence referring to T2WI alone and then to DWI, T2WI, and fusion images (DWI+T2WI) for each EPI-DWI and TSE-DWI. Visual score assessments of image quality were performed for each DWI. RESULTS: Inter-observer agreement of T-staging for 10 readers was slight on T2WI alone but fair on EPI-DWI+T2WI and excellent on TSE-DWI+T2WI images. No readers gave higher confidence scores for T2WI compared to EPI/TSE-DWI+T2WI and for EPI-DWI+T2WI compared to TSE-DWI+T2WI. In seven pathologically-proven cases, poor, poor to slight, and fair to perfect agreements with the pathological T-stage were observed with T2WI alone, EPI-DWI+T2WI, and TSE-DWI+T2WI, respectively. All readers gave higher scores regarding image distortion and lower scores regarding image noise for TSE-DWI compared to EPI-DWI. For DWI utility, higher scores were assigned for TSE-DWI compared to EPI-DWI in 7 readers and there were no significant differences in the other 3 readers. CONCLUSION: TSE-DWI images might be more appropriate for image fusion with T2WI and rectal cancer T-staging compared with EPI-DWI and T2WI alone. Public Library of Science 2021-04-21 /pmc/articles/PMC8059798/ /pubmed/33882087 http://dx.doi.org/10.1371/journal.pone.0249433 Text en © 2021 Ogawa et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Ogawa, Masaki
Urano, Misugi
Takaishi, Taku
Kan, Hirohito
Arai, Nobuyuki
Takahashi, Hiroki
Hara, Masayasu
Saito, Miki
Shibamoto, Yuta
T-staging of rectal cancer: Utility of single-shot turbo spin-echo diffusion-weighted imaging with T2-weighted images and fusion images
title T-staging of rectal cancer: Utility of single-shot turbo spin-echo diffusion-weighted imaging with T2-weighted images and fusion images
title_full T-staging of rectal cancer: Utility of single-shot turbo spin-echo diffusion-weighted imaging with T2-weighted images and fusion images
title_fullStr T-staging of rectal cancer: Utility of single-shot turbo spin-echo diffusion-weighted imaging with T2-weighted images and fusion images
title_full_unstemmed T-staging of rectal cancer: Utility of single-shot turbo spin-echo diffusion-weighted imaging with T2-weighted images and fusion images
title_short T-staging of rectal cancer: Utility of single-shot turbo spin-echo diffusion-weighted imaging with T2-weighted images and fusion images
title_sort t-staging of rectal cancer: utility of single-shot turbo spin-echo diffusion-weighted imaging with t2-weighted images and fusion images
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8059798/
https://www.ncbi.nlm.nih.gov/pubmed/33882087
http://dx.doi.org/10.1371/journal.pone.0249433
work_keys_str_mv AT ogawamasaki tstagingofrectalcancerutilityofsingleshotturbospinechodiffusionweightedimagingwitht2weightedimagesandfusionimages
AT uranomisugi tstagingofrectalcancerutilityofsingleshotturbospinechodiffusionweightedimagingwitht2weightedimagesandfusionimages
AT takaishitaku tstagingofrectalcancerutilityofsingleshotturbospinechodiffusionweightedimagingwitht2weightedimagesandfusionimages
AT kanhirohito tstagingofrectalcancerutilityofsingleshotturbospinechodiffusionweightedimagingwitht2weightedimagesandfusionimages
AT arainobuyuki tstagingofrectalcancerutilityofsingleshotturbospinechodiffusionweightedimagingwitht2weightedimagesandfusionimages
AT takahashihiroki tstagingofrectalcancerutilityofsingleshotturbospinechodiffusionweightedimagingwitht2weightedimagesandfusionimages
AT haramasayasu tstagingofrectalcancerutilityofsingleshotturbospinechodiffusionweightedimagingwitht2weightedimagesandfusionimages
AT saitomiki tstagingofrectalcancerutilityofsingleshotturbospinechodiffusionweightedimagingwitht2weightedimagesandfusionimages
AT shibamotoyuta tstagingofrectalcancerutilityofsingleshotturbospinechodiffusionweightedimagingwitht2weightedimagesandfusionimages