The Effects of a Senofilcon A Contact Lens With and Without a Photochromic Additive on Positive Dysphotopsia Across Age
OBJECTIVE: The visual effects of wearing a photochromic contact lens (test) were directly compared with a nonphotochromic contact lens (control). Positive dysphotopsia (halos, starbursts) and intraocular scatter (behaviorally determined) were assessed. Both younger and middle-aged subjects were eval...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Eye & Contact Lens: Science & Clinical Practice
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8059875/ https://www.ncbi.nlm.nih.gov/pubmed/33878065 http://dx.doi.org/10.1097/ICL.0000000000000731 |
Sumario: | OBJECTIVE: The visual effects of wearing a photochromic contact lens (test) were directly compared with a nonphotochromic contact lens (control). Positive dysphotopsia (halos, starbursts) and intraocular scatter (behaviorally determined) were assessed. Both younger and middle-aged subjects were evaluated to examine the influence of age. METHODS: Fifty-four subjects (18–62 years) were tested using a contralateral design. Subjects were fit with a photochromic contact lens on one eye and a nonphotochromic contact lens on the other eye, randomly assigned. Testing occurred with and without photochromic activation (darkened) by use of a violet activator (365 nm, half-bandwidth 20 nm). The extent of dysphotopsia (halos and spokes) was measured using an aperture (∼4 mm) that created a bright point source of light 45 inches from the plane of the eye. Between the point source and subject, a centering precision caliper was used to measure lateral spread. Two-point thresholds were determined by measuring the minimum distance between two points of broadband xenon light. RESULTS: The photochromic contact lens produced smaller halo diameters than the control contact lens, both activated (41% on average) and inactivated (21% on average), and age strata was a significant factor (P<0.001) with the older group showing a greater reduction. The photochromic contact lens produced smaller starburst diameters than the control contact lens, both activated (37% on average) and inactivated (23% on average), and age strata was a significant factor (P=0.001) with the older group showing a greater reduction. The two-point thresholds were reduced (25% activated, 9% inactivated) on average but the age effect was not significant (P<0.10). CONCLUSIONS: The senofilcon A lens with photochromic additive reduced the extent of positive dysphotopsia compared with the same lens without the additive, regardless whether the lens was activated or not. The visual benefit was greatest with the older subjects. |
---|