Cargando…
Intra-operative ocular ultrasonography of iodine-125 brachytherapy plaques in patients with uveal melanoma
PURPOSE: Brachytherapy with iodine-125 ((125)I) has been extensively used as a conservative treatment for uveal melanoma (UM). Surgical technique for correct placement of episcleral radioactive plaques (ERP) in UM cases with posterior choroidal location and/or small size can be difficult and inaccur...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8060954/ https://www.ncbi.nlm.nih.gov/pubmed/33897785 http://dx.doi.org/10.5114/jcb.2021.105279 |
_version_ | 1783681466333396992 |
---|---|
author | Ces, Antonio Piñeiro Rodriguez, Manuel Bande Sueiro, Javier Mosquero Castro, Ana María Carballo Busto, Ramón Lobato Rodriguez, Paula Silva Pérez, María Pardo Oliva-Ruiz, Francisco Ruiz Teijeiro, Maria Jose Blanco |
author_facet | Ces, Antonio Piñeiro Rodriguez, Manuel Bande Sueiro, Javier Mosquero Castro, Ana María Carballo Busto, Ramón Lobato Rodriguez, Paula Silva Pérez, María Pardo Oliva-Ruiz, Francisco Ruiz Teijeiro, Maria Jose Blanco |
author_sort | Ces, Antonio Piñeiro |
collection | PubMed |
description | PURPOSE: Brachytherapy with iodine-125 ((125)I) has been extensively used as a conservative treatment for uveal melanoma (UM). Surgical technique for correct placement of episcleral radioactive plaques (ERP) in UM cases with posterior choroidal location and/or small size can be difficult and inaccurate. In this study, the correct positioning of plaques was assessed by intra-operative ultrasound control. MATERIAL AND METHODS: This was a longitudinal, retrospective study of consecutive 20 patients with UM (small-medium size and/or posterior location) who received (125)I brachytherapy. Location of plaques was adjusted by intra-operative ocular ultrasonography control. To perform ocular intra-operative ultrasonography, a 10 MHz probe was used to longitudinal and transverse bases in corresponding dummy plaques. RESULTS: The study included 8 males and 12 females, with a mean age of 66.3 years (SD = 14.53), 5 right eyes (RE) and 15 left eyes (LE). In ultrasound examination, 4 UMs were of mushroom morphology and the rest nodular. Means of the size of UM by ultrasound were (mm): Lb: 10.60 (SD = 2.24) × Tb: 9.88 (SD = 1.54) × H: 4.02 (SD = 1.44) (3 cases corresponding to small size of collaborative ocular melanoma study (COMS), and 17 cases to medium). The plaques used were between 14 and 20 mm in diameter, with an average distance between the edge of greater base of the tumor and the edge of plate of 2.44 mm (SD = 0.34). It was necessary to surgically reposition the plaque in 4 cases (20%). CONCLUSIONS: Intra-operative ultrasound control improves the accuracy of radioactive plaque placement for the treatment of medium-small UMs in posterior location. Probably, this technique should be applied in all cases of brachytherapy, regardless of the isotope chosen and the location of tumor mass, in order to perfectly adjust therapeutic position. |
format | Online Article Text |
id | pubmed-8060954 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-80609542021-04-23 Intra-operative ocular ultrasonography of iodine-125 brachytherapy plaques in patients with uveal melanoma Ces, Antonio Piñeiro Rodriguez, Manuel Bande Sueiro, Javier Mosquero Castro, Ana María Carballo Busto, Ramón Lobato Rodriguez, Paula Silva Pérez, María Pardo Oliva-Ruiz, Francisco Ruiz Teijeiro, Maria Jose Blanco J Contemp Brachytherapy Original Paper PURPOSE: Brachytherapy with iodine-125 ((125)I) has been extensively used as a conservative treatment for uveal melanoma (UM). Surgical technique for correct placement of episcleral radioactive plaques (ERP) in UM cases with posterior choroidal location and/or small size can be difficult and inaccurate. In this study, the correct positioning of plaques was assessed by intra-operative ultrasound control. MATERIAL AND METHODS: This was a longitudinal, retrospective study of consecutive 20 patients with UM (small-medium size and/or posterior location) who received (125)I brachytherapy. Location of plaques was adjusted by intra-operative ocular ultrasonography control. To perform ocular intra-operative ultrasonography, a 10 MHz probe was used to longitudinal and transverse bases in corresponding dummy plaques. RESULTS: The study included 8 males and 12 females, with a mean age of 66.3 years (SD = 14.53), 5 right eyes (RE) and 15 left eyes (LE). In ultrasound examination, 4 UMs were of mushroom morphology and the rest nodular. Means of the size of UM by ultrasound were (mm): Lb: 10.60 (SD = 2.24) × Tb: 9.88 (SD = 1.54) × H: 4.02 (SD = 1.44) (3 cases corresponding to small size of collaborative ocular melanoma study (COMS), and 17 cases to medium). The plaques used were between 14 and 20 mm in diameter, with an average distance between the edge of greater base of the tumor and the edge of plate of 2.44 mm (SD = 0.34). It was necessary to surgically reposition the plaque in 4 cases (20%). CONCLUSIONS: Intra-operative ultrasound control improves the accuracy of radioactive plaque placement for the treatment of medium-small UMs in posterior location. Probably, this technique should be applied in all cases of brachytherapy, regardless of the isotope chosen and the location of tumor mass, in order to perfectly adjust therapeutic position. Termedia Publishing House 2021-04-14 2021-04 /pmc/articles/PMC8060954/ /pubmed/33897785 http://dx.doi.org/10.5114/jcb.2021.105279 Text en Copyright © 2021 Termedia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/ (https://creativecommons.org/licenses/by-nc-sa/4.0/) ) |
spellingShingle | Original Paper Ces, Antonio Piñeiro Rodriguez, Manuel Bande Sueiro, Javier Mosquero Castro, Ana María Carballo Busto, Ramón Lobato Rodriguez, Paula Silva Pérez, María Pardo Oliva-Ruiz, Francisco Ruiz Teijeiro, Maria Jose Blanco Intra-operative ocular ultrasonography of iodine-125 brachytherapy plaques in patients with uveal melanoma |
title | Intra-operative ocular ultrasonography of iodine-125 brachytherapy plaques in patients with uveal melanoma |
title_full | Intra-operative ocular ultrasonography of iodine-125 brachytherapy plaques in patients with uveal melanoma |
title_fullStr | Intra-operative ocular ultrasonography of iodine-125 brachytherapy plaques in patients with uveal melanoma |
title_full_unstemmed | Intra-operative ocular ultrasonography of iodine-125 brachytherapy plaques in patients with uveal melanoma |
title_short | Intra-operative ocular ultrasonography of iodine-125 brachytherapy plaques in patients with uveal melanoma |
title_sort | intra-operative ocular ultrasonography of iodine-125 brachytherapy plaques in patients with uveal melanoma |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8060954/ https://www.ncbi.nlm.nih.gov/pubmed/33897785 http://dx.doi.org/10.5114/jcb.2021.105279 |
work_keys_str_mv | AT cesantoniopineiro intraoperativeocularultrasonographyofiodine125brachytherapyplaquesinpatientswithuvealmelanoma AT rodriguezmanuelbande intraoperativeocularultrasonographyofiodine125brachytherapyplaquesinpatientswithuvealmelanoma AT sueirojaviermosquero intraoperativeocularultrasonographyofiodine125brachytherapyplaquesinpatientswithuvealmelanoma AT castroanamariacarballo intraoperativeocularultrasonographyofiodine125brachytherapyplaquesinpatientswithuvealmelanoma AT bustoramonlobato intraoperativeocularultrasonographyofiodine125brachytherapyplaquesinpatientswithuvealmelanoma AT rodriguezpaulasilva intraoperativeocularultrasonographyofiodine125brachytherapyplaquesinpatientswithuvealmelanoma AT perezmariapardo intraoperativeocularultrasonographyofiodine125brachytherapyplaquesinpatientswithuvealmelanoma AT olivaruizfranciscoruiz intraoperativeocularultrasonographyofiodine125brachytherapyplaquesinpatientswithuvealmelanoma AT teijeiromariajoseblanco intraoperativeocularultrasonographyofiodine125brachytherapyplaquesinpatientswithuvealmelanoma |