Cargando…
Outcome of Trabeculectomy with Collagen Matrix Implant versus Mitomycin C in Primary Glaucoma: A Comparative Study
BACKGROUND: Glaucoma is a serious vision-threatening condition appropriately called as the silent killer of sight. The effect of postoperative fibrosis on success of filtration surgeries requires modulation of the wound healing process. AIM: The aim of the study was to compare trabeculectomy augment...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8061608/ https://www.ncbi.nlm.nih.gov/pubmed/33912426 http://dx.doi.org/10.4103/ijabmr.IJABMR_609_20 |
_version_ | 1783681600605650944 |
---|---|
author | Sharma, Ashok K. Gupta, Palak Sharma, Hans Raj |
author_facet | Sharma, Ashok K. Gupta, Palak Sharma, Hans Raj |
author_sort | Sharma, Ashok K. |
collection | PubMed |
description | BACKGROUND: Glaucoma is a serious vision-threatening condition appropriately called as the silent killer of sight. The effect of postoperative fibrosis on success of filtration surgeries requires modulation of the wound healing process. AIM: The aim of the study was to compare trabeculectomy augmented with collagen matrix implant with mitomycin C in primary glaucoma. MATERIALS AND METHODS: This prospective, longitudinal, hospital-based, analytical, and interventional study was conducted on 36 eyes of 36 patients. Group 1 included 18 patients who underwent trabeculectomy combined with subconjunctival collagen matrix implant and Group 2 included 18 patients who underwent trabeculectomy augmented with intraoperative mitomycin C (0.04 mg/ml) for 2 min. Each patient underwent detailed ocular examination and comparison was drawn by recording intraocular pressure (IOP), bleb characteristics, and postoperative complications. RESULTS: The cumulative success rates at the end of our study were similar in two groups, 94.44% in Group 1 and 88.89% in Group 2 (P = 1.000). The mean reduction in IOP at 24 weeks in Group 1 was 18.67 ± 7.59 mmHg and in Group 2 was 21.32 ± 5.84 mmHg. The reduction in IOP was similar between the two groups (P = 0.290). The mean fall in IOP was 56.46% in Group 1 and 64.70% in Group 2 at 24 weeks. Mean bleb score in Group 1 was 10.33 ± 1.23 and in Group 2 was 8.89 ± 1.41, and the difference was statistically significant (P = 0.002). Shallow anterior chamber, overfiltration, and hypotony were statistically higher in Group 2 than in Group 1 (P = 0.041, 0.041, and 0.046, respectively). CONCLUSION: Collagen matrix implant as an adjuvant to trabeculectomy is noble, safe, and effective option as compared to mitomycin C. |
format | Online Article Text |
id | pubmed-8061608 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-80616082021-04-27 Outcome of Trabeculectomy with Collagen Matrix Implant versus Mitomycin C in Primary Glaucoma: A Comparative Study Sharma, Ashok K. Gupta, Palak Sharma, Hans Raj Int J Appl Basic Med Res Original Article BACKGROUND: Glaucoma is a serious vision-threatening condition appropriately called as the silent killer of sight. The effect of postoperative fibrosis on success of filtration surgeries requires modulation of the wound healing process. AIM: The aim of the study was to compare trabeculectomy augmented with collagen matrix implant with mitomycin C in primary glaucoma. MATERIALS AND METHODS: This prospective, longitudinal, hospital-based, analytical, and interventional study was conducted on 36 eyes of 36 patients. Group 1 included 18 patients who underwent trabeculectomy combined with subconjunctival collagen matrix implant and Group 2 included 18 patients who underwent trabeculectomy augmented with intraoperative mitomycin C (0.04 mg/ml) for 2 min. Each patient underwent detailed ocular examination and comparison was drawn by recording intraocular pressure (IOP), bleb characteristics, and postoperative complications. RESULTS: The cumulative success rates at the end of our study were similar in two groups, 94.44% in Group 1 and 88.89% in Group 2 (P = 1.000). The mean reduction in IOP at 24 weeks in Group 1 was 18.67 ± 7.59 mmHg and in Group 2 was 21.32 ± 5.84 mmHg. The reduction in IOP was similar between the two groups (P = 0.290). The mean fall in IOP was 56.46% in Group 1 and 64.70% in Group 2 at 24 weeks. Mean bleb score in Group 1 was 10.33 ± 1.23 and in Group 2 was 8.89 ± 1.41, and the difference was statistically significant (P = 0.002). Shallow anterior chamber, overfiltration, and hypotony were statistically higher in Group 2 than in Group 1 (P = 0.041, 0.041, and 0.046, respectively). CONCLUSION: Collagen matrix implant as an adjuvant to trabeculectomy is noble, safe, and effective option as compared to mitomycin C. Wolters Kluwer - Medknow 2021 2021-04-08 /pmc/articles/PMC8061608/ /pubmed/33912426 http://dx.doi.org/10.4103/ijabmr.IJABMR_609_20 Text en Copyright: © 2021 International Journal of Applied and Basic Medical Research https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Sharma, Ashok K. Gupta, Palak Sharma, Hans Raj Outcome of Trabeculectomy with Collagen Matrix Implant versus Mitomycin C in Primary Glaucoma: A Comparative Study |
title | Outcome of Trabeculectomy with Collagen Matrix Implant versus Mitomycin C in Primary Glaucoma: A Comparative Study |
title_full | Outcome of Trabeculectomy with Collagen Matrix Implant versus Mitomycin C in Primary Glaucoma: A Comparative Study |
title_fullStr | Outcome of Trabeculectomy with Collagen Matrix Implant versus Mitomycin C in Primary Glaucoma: A Comparative Study |
title_full_unstemmed | Outcome of Trabeculectomy with Collagen Matrix Implant versus Mitomycin C in Primary Glaucoma: A Comparative Study |
title_short | Outcome of Trabeculectomy with Collagen Matrix Implant versus Mitomycin C in Primary Glaucoma: A Comparative Study |
title_sort | outcome of trabeculectomy with collagen matrix implant versus mitomycin c in primary glaucoma: a comparative study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8061608/ https://www.ncbi.nlm.nih.gov/pubmed/33912426 http://dx.doi.org/10.4103/ijabmr.IJABMR_609_20 |
work_keys_str_mv | AT sharmaashokk outcomeoftrabeculectomywithcollagenmatriximplantversusmitomycincinprimaryglaucomaacomparativestudy AT guptapalak outcomeoftrabeculectomywithcollagenmatriximplantversusmitomycincinprimaryglaucomaacomparativestudy AT sharmahansraj outcomeoftrabeculectomywithcollagenmatriximplantversusmitomycincinprimaryglaucomaacomparativestudy |