Cargando…
Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Biopsy Device for Lymphadenopathy
BACKGROUND: Accurate diagnosis of benign and malignant lymphadenopathy is important for determining the appropriate treatment and prognosis. This study evaluated the diagnostic accuracy and usefulness of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) with a conventional needle compare...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8062193/ https://www.ncbi.nlm.nih.gov/pubmed/33936195 http://dx.doi.org/10.1155/2021/6640862 |
_version_ | 1783681718781214720 |
---|---|
author | Tanisaka, Yuki Mizuide, Masafumi Fujita, Akashi Ogawa, Tomoya Araki, Ryuichiro Suzuki, Masahiro Katsuda, Hiromune Saito, Youichi Miyaguchi, Kazuya Tashima, Tomoaki Mashimo, Yumi Yasuda, Masami Ryozawa, Shomei |
author_facet | Tanisaka, Yuki Mizuide, Masafumi Fujita, Akashi Ogawa, Tomoya Araki, Ryuichiro Suzuki, Masahiro Katsuda, Hiromune Saito, Youichi Miyaguchi, Kazuya Tashima, Tomoaki Mashimo, Yumi Yasuda, Masami Ryozawa, Shomei |
author_sort | Tanisaka, Yuki |
collection | PubMed |
description | BACKGROUND: Accurate diagnosis of benign and malignant lymphadenopathy is important for determining the appropriate treatment and prognosis. This study evaluated the diagnostic accuracy and usefulness of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) with a conventional needle compared to endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) with a Franseen needle for diagnosing lymphadenopathy. METHODS: Patients who underwent EUS-FNA or EUS-FNB for mediastinal or abdominal lymphadenopathy between July 2013 and August 2020 were enrolled in the study. The outcomes between EUS-FNA patients (July 2013 to January 2017; 22-gauge conventional needle; Group A) and EUS-FNB patients (February 2017 to August 2020; 22-gauge Franseen needle; Group B) were compared. RESULTS: A total of 154 patients (Group A: 83; Group B: 71) were analyzed. The diagnostic accuracy (differentiating between malignant and benign lesions) was 88.0% (95% confidence interval [CI], 79.2–93.3%) in Group A and 95.8% (95% CI, 88.3–98.8%) in Group B. Group B had high diagnostic accuracy, but there was no difference between the groups (p = 0.14). Group B had significantly fewer passes (median 2, interquartile range (IQR): 2-4) than Group A (median 3, IQR: 3-4) (p < 0.001). No procedural adverse events occurred in either group. CONCLUSIONS: Although the diagnostic accuracy between the groups was not statistically significant, EUS-FNB with a Franseen needle provided high diagnostic accuracy and required fewer passes to establish a diagnosis. Thus, EUS-FNB is useful for diagnosing lymphadenopathy. |
format | Online Article Text |
id | pubmed-8062193 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-80621932021-04-29 Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Biopsy Device for Lymphadenopathy Tanisaka, Yuki Mizuide, Masafumi Fujita, Akashi Ogawa, Tomoya Araki, Ryuichiro Suzuki, Masahiro Katsuda, Hiromune Saito, Youichi Miyaguchi, Kazuya Tashima, Tomoaki Mashimo, Yumi Yasuda, Masami Ryozawa, Shomei Gastroenterol Res Pract Research Article BACKGROUND: Accurate diagnosis of benign and malignant lymphadenopathy is important for determining the appropriate treatment and prognosis. This study evaluated the diagnostic accuracy and usefulness of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) with a conventional needle compared to endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) with a Franseen needle for diagnosing lymphadenopathy. METHODS: Patients who underwent EUS-FNA or EUS-FNB for mediastinal or abdominal lymphadenopathy between July 2013 and August 2020 were enrolled in the study. The outcomes between EUS-FNA patients (July 2013 to January 2017; 22-gauge conventional needle; Group A) and EUS-FNB patients (February 2017 to August 2020; 22-gauge Franseen needle; Group B) were compared. RESULTS: A total of 154 patients (Group A: 83; Group B: 71) were analyzed. The diagnostic accuracy (differentiating between malignant and benign lesions) was 88.0% (95% confidence interval [CI], 79.2–93.3%) in Group A and 95.8% (95% CI, 88.3–98.8%) in Group B. Group B had high diagnostic accuracy, but there was no difference between the groups (p = 0.14). Group B had significantly fewer passes (median 2, interquartile range (IQR): 2-4) than Group A (median 3, IQR: 3-4) (p < 0.001). No procedural adverse events occurred in either group. CONCLUSIONS: Although the diagnostic accuracy between the groups was not statistically significant, EUS-FNB with a Franseen needle provided high diagnostic accuracy and required fewer passes to establish a diagnosis. Thus, EUS-FNB is useful for diagnosing lymphadenopathy. Hindawi 2021-04-15 /pmc/articles/PMC8062193/ /pubmed/33936195 http://dx.doi.org/10.1155/2021/6640862 Text en Copyright © 2021 Yuki Tanisaka et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Tanisaka, Yuki Mizuide, Masafumi Fujita, Akashi Ogawa, Tomoya Araki, Ryuichiro Suzuki, Masahiro Katsuda, Hiromune Saito, Youichi Miyaguchi, Kazuya Tashima, Tomoaki Mashimo, Yumi Yasuda, Masami Ryozawa, Shomei Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Biopsy Device for Lymphadenopathy |
title | Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Biopsy Device for Lymphadenopathy |
title_full | Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Biopsy Device for Lymphadenopathy |
title_fullStr | Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Biopsy Device for Lymphadenopathy |
title_full_unstemmed | Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Biopsy Device for Lymphadenopathy |
title_short | Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Biopsy Device for Lymphadenopathy |
title_sort | comparison of endoscopic ultrasound-guided fine-needle aspiration and biopsy device for lymphadenopathy |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8062193/ https://www.ncbi.nlm.nih.gov/pubmed/33936195 http://dx.doi.org/10.1155/2021/6640862 |
work_keys_str_mv | AT tanisakayuki comparisonofendoscopicultrasoundguidedfineneedleaspirationandbiopsydeviceforlymphadenopathy AT mizuidemasafumi comparisonofendoscopicultrasoundguidedfineneedleaspirationandbiopsydeviceforlymphadenopathy AT fujitaakashi comparisonofendoscopicultrasoundguidedfineneedleaspirationandbiopsydeviceforlymphadenopathy AT ogawatomoya comparisonofendoscopicultrasoundguidedfineneedleaspirationandbiopsydeviceforlymphadenopathy AT arakiryuichiro comparisonofendoscopicultrasoundguidedfineneedleaspirationandbiopsydeviceforlymphadenopathy AT suzukimasahiro comparisonofendoscopicultrasoundguidedfineneedleaspirationandbiopsydeviceforlymphadenopathy AT katsudahiromune comparisonofendoscopicultrasoundguidedfineneedleaspirationandbiopsydeviceforlymphadenopathy AT saitoyouichi comparisonofendoscopicultrasoundguidedfineneedleaspirationandbiopsydeviceforlymphadenopathy AT miyaguchikazuya comparisonofendoscopicultrasoundguidedfineneedleaspirationandbiopsydeviceforlymphadenopathy AT tashimatomoaki comparisonofendoscopicultrasoundguidedfineneedleaspirationandbiopsydeviceforlymphadenopathy AT mashimoyumi comparisonofendoscopicultrasoundguidedfineneedleaspirationandbiopsydeviceforlymphadenopathy AT yasudamasami comparisonofendoscopicultrasoundguidedfineneedleaspirationandbiopsydeviceforlymphadenopathy AT ryozawashomei comparisonofendoscopicultrasoundguidedfineneedleaspirationandbiopsydeviceforlymphadenopathy |