Cargando…
A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years
BACKGROUND: Implantable collamer lens (ICL) might rarely cause complications that warrant explantation. Here, we presented a case of inverted ICL that has undergone explantation after a 10-year duration. Case Presentation. A 49-year-old male with past ocular history of ICL implantation 10 years ago...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8062202/ https://www.ncbi.nlm.nih.gov/pubmed/33953998 http://dx.doi.org/10.1155/2021/6641475 |
_version_ | 1783681720878366720 |
---|---|
author | AlQahtani, Bader S. Alshamrani, Abdulaziz A. Alsulami, Raed E. Vargas, Jose M. |
author_facet | AlQahtani, Bader S. Alshamrani, Abdulaziz A. Alsulami, Raed E. Vargas, Jose M. |
author_sort | AlQahtani, Bader S. |
collection | PubMed |
description | BACKGROUND: Implantable collamer lens (ICL) might rarely cause complications that warrant explantation. Here, we presented a case of inverted ICL that has undergone explantation after a 10-year duration. Case Presentation. A 49-year-old male with past ocular history of ICL implantation 10 years ago presented complaining of progressive decrease of visual acuity in the left eye for a long time. On examination, decreased visual acuity, anterior subcapsular cataract, and low ICL vault were noted. The anterior segment optical coherence tomography (AS OCT) showed inverted ICL. The ICL was explanted, and cataract surgery was done. CONCLUSION: Inverted ICL should be kept in mind as a rare cause of long-term poor visual acuity in patient with a history of ICL surgery. |
format | Online Article Text |
id | pubmed-8062202 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-80622022021-05-04 A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years AlQahtani, Bader S. Alshamrani, Abdulaziz A. Alsulami, Raed E. Vargas, Jose M. Case Rep Ophthalmol Med Case Report BACKGROUND: Implantable collamer lens (ICL) might rarely cause complications that warrant explantation. Here, we presented a case of inverted ICL that has undergone explantation after a 10-year duration. Case Presentation. A 49-year-old male with past ocular history of ICL implantation 10 years ago presented complaining of progressive decrease of visual acuity in the left eye for a long time. On examination, decreased visual acuity, anterior subcapsular cataract, and low ICL vault were noted. The anterior segment optical coherence tomography (AS OCT) showed inverted ICL. The ICL was explanted, and cataract surgery was done. CONCLUSION: Inverted ICL should be kept in mind as a rare cause of long-term poor visual acuity in patient with a history of ICL surgery. Hindawi 2021-04-14 /pmc/articles/PMC8062202/ /pubmed/33953998 http://dx.doi.org/10.1155/2021/6641475 Text en Copyright © 2021 Bader S. AlQahtani et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report AlQahtani, Bader S. Alshamrani, Abdulaziz A. Alsulami, Raed E. Vargas, Jose M. A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years |
title | A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years |
title_full | A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years |
title_fullStr | A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years |
title_full_unstemmed | A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years |
title_short | A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years |
title_sort | case of implantable collamer lens (icl) with reverse orientation for 10 years |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8062202/ https://www.ncbi.nlm.nih.gov/pubmed/33953998 http://dx.doi.org/10.1155/2021/6641475 |
work_keys_str_mv | AT alqahtanibaders acaseofimplantablecollamerlensiclwithreverseorientationfor10years AT alshamraniabdulaziza acaseofimplantablecollamerlensiclwithreverseorientationfor10years AT alsulamiraede acaseofimplantablecollamerlensiclwithreverseorientationfor10years AT vargasjosem acaseofimplantablecollamerlensiclwithreverseorientationfor10years AT alqahtanibaders caseofimplantablecollamerlensiclwithreverseorientationfor10years AT alshamraniabdulaziza caseofimplantablecollamerlensiclwithreverseorientationfor10years AT alsulamiraede caseofimplantablecollamerlensiclwithreverseorientationfor10years AT vargasjosem caseofimplantablecollamerlensiclwithreverseorientationfor10years |