Cargando…
An Improved Method of Automated Noise Measurement System in CT Images
BACKGROUND: It is necessary to have an automated noise measurement system working accurately to optimize dose in computerized tomography (CT) examinations. OBJECTIVE: This study aims to develop an algorithm to automate noise measurement that can be implemented in CT images of all body regions. MATER...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shiraz University of Medical Sciences
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8064134/ https://www.ncbi.nlm.nih.gov/pubmed/33937124 http://dx.doi.org/10.31661/jbpe.v0i0.1198 |
_version_ | 1783682069276131328 |
---|---|
author | Anam, Choirul Arif, Idam Haryanto, Freddy Lestari, Fauzia P Widita, Rena Budi, Wahyu S Sutanto, Heri Adi, Kusworo Fujibuchi, Toshioh Dougherty, Geoff |
author_facet | Anam, Choirul Arif, Idam Haryanto, Freddy Lestari, Fauzia P Widita, Rena Budi, Wahyu S Sutanto, Heri Adi, Kusworo Fujibuchi, Toshioh Dougherty, Geoff |
author_sort | Anam, Choirul |
collection | PubMed |
description | BACKGROUND: It is necessary to have an automated noise measurement system working accurately to optimize dose in computerized tomography (CT) examinations. OBJECTIVE: This study aims to develop an algorithm to automate noise measurement that can be implemented in CT images of all body regions. MATERIALS AND METHODS: In this retrospective study, our automated noise measurement method consists of three steps as follows: the first is segmenting the image of the patient. The second is developing a standard deviation (SD) map by calculating the SD value for each pixel with a sliding window operation. The third step is estimating the noise as the smallest SD from the SD map. The proposed method was applied to the images of a homogenous phantom and a full body adult anthropomorphic phantom, and retrospectively applied to 27 abdominal images of patients. RESULTS: For a homogeneous phantom, the noises calculated using our proposed and previous algorithms have a linear correlation with R(2) = 0.997. It is found that the noise magnitude closely follows the magnitude of the water equivalent diameter (D(w)) in all body regions. The proposed algorithm is able to distinguish the noise magnitude due to variations in tube currents and different noise suppression techniques such as strong, standard, mild, and weak ones in a reconstructed image using the AIDR 3D algorithm. CONCLUSION: An automated noise calculation has been proposed and successfully implemented in all body regions. It is not only accurate and easy to implement but also not influenced by the subjectivity of user. |
format | Online Article Text |
id | pubmed-8064134 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Shiraz University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-80641342021-04-30 An Improved Method of Automated Noise Measurement System in CT Images Anam, Choirul Arif, Idam Haryanto, Freddy Lestari, Fauzia P Widita, Rena Budi, Wahyu S Sutanto, Heri Adi, Kusworo Fujibuchi, Toshioh Dougherty, Geoff J Biomed Phys Eng Original Article BACKGROUND: It is necessary to have an automated noise measurement system working accurately to optimize dose in computerized tomography (CT) examinations. OBJECTIVE: This study aims to develop an algorithm to automate noise measurement that can be implemented in CT images of all body regions. MATERIALS AND METHODS: In this retrospective study, our automated noise measurement method consists of three steps as follows: the first is segmenting the image of the patient. The second is developing a standard deviation (SD) map by calculating the SD value for each pixel with a sliding window operation. The third step is estimating the noise as the smallest SD from the SD map. The proposed method was applied to the images of a homogenous phantom and a full body adult anthropomorphic phantom, and retrospectively applied to 27 abdominal images of patients. RESULTS: For a homogeneous phantom, the noises calculated using our proposed and previous algorithms have a linear correlation with R(2) = 0.997. It is found that the noise magnitude closely follows the magnitude of the water equivalent diameter (D(w)) in all body regions. The proposed algorithm is able to distinguish the noise magnitude due to variations in tube currents and different noise suppression techniques such as strong, standard, mild, and weak ones in a reconstructed image using the AIDR 3D algorithm. CONCLUSION: An automated noise calculation has been proposed and successfully implemented in all body regions. It is not only accurate and easy to implement but also not influenced by the subjectivity of user. Shiraz University of Medical Sciences 2021-04-01 /pmc/articles/PMC8064134/ /pubmed/33937124 http://dx.doi.org/10.31661/jbpe.v0i0.1198 Text en Copyright: © Journal of Biomedical Physics and Engineering https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 Unported License, ( http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Anam, Choirul Arif, Idam Haryanto, Freddy Lestari, Fauzia P Widita, Rena Budi, Wahyu S Sutanto, Heri Adi, Kusworo Fujibuchi, Toshioh Dougherty, Geoff An Improved Method of Automated Noise Measurement System in CT Images |
title | An Improved Method of Automated Noise Measurement System in CT Images |
title_full | An Improved Method of Automated Noise Measurement System in CT Images |
title_fullStr | An Improved Method of Automated Noise Measurement System in CT Images |
title_full_unstemmed | An Improved Method of Automated Noise Measurement System in CT Images |
title_short | An Improved Method of Automated Noise Measurement System in CT Images |
title_sort | improved method of automated noise measurement system in ct images |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8064134/ https://www.ncbi.nlm.nih.gov/pubmed/33937124 http://dx.doi.org/10.31661/jbpe.v0i0.1198 |
work_keys_str_mv | AT anamchoirul animprovedmethodofautomatednoisemeasurementsysteminctimages AT arifidam animprovedmethodofautomatednoisemeasurementsysteminctimages AT haryantofreddy animprovedmethodofautomatednoisemeasurementsysteminctimages AT lestarifauziap animprovedmethodofautomatednoisemeasurementsysteminctimages AT widitarena animprovedmethodofautomatednoisemeasurementsysteminctimages AT budiwahyus animprovedmethodofautomatednoisemeasurementsysteminctimages AT sutantoheri animprovedmethodofautomatednoisemeasurementsysteminctimages AT adikusworo animprovedmethodofautomatednoisemeasurementsysteminctimages AT fujibuchitoshioh animprovedmethodofautomatednoisemeasurementsysteminctimages AT doughertygeoff animprovedmethodofautomatednoisemeasurementsysteminctimages AT anamchoirul improvedmethodofautomatednoisemeasurementsysteminctimages AT arifidam improvedmethodofautomatednoisemeasurementsysteminctimages AT haryantofreddy improvedmethodofautomatednoisemeasurementsysteminctimages AT lestarifauziap improvedmethodofautomatednoisemeasurementsysteminctimages AT widitarena improvedmethodofautomatednoisemeasurementsysteminctimages AT budiwahyus improvedmethodofautomatednoisemeasurementsysteminctimages AT sutantoheri improvedmethodofautomatednoisemeasurementsysteminctimages AT adikusworo improvedmethodofautomatednoisemeasurementsysteminctimages AT fujibuchitoshioh improvedmethodofautomatednoisemeasurementsysteminctimages AT doughertygeoff improvedmethodofautomatednoisemeasurementsysteminctimages |