Cargando…

An Improved Method of Automated Noise Measurement System in CT Images

BACKGROUND: It is necessary to have an automated noise measurement system working accurately to optimize dose in computerized tomography (CT) examinations. OBJECTIVE: This study aims to develop an algorithm to automate noise measurement that can be implemented in CT images of all body regions. MATER...

Descripción completa

Detalles Bibliográficos
Autores principales: Anam, Choirul, Arif, Idam, Haryanto, Freddy, Lestari, Fauzia P, Widita, Rena, Budi, Wahyu S, Sutanto, Heri, Adi, Kusworo, Fujibuchi, Toshioh, Dougherty, Geoff
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8064134/
https://www.ncbi.nlm.nih.gov/pubmed/33937124
http://dx.doi.org/10.31661/jbpe.v0i0.1198
_version_ 1783682069276131328
author Anam, Choirul
Arif, Idam
Haryanto, Freddy
Lestari, Fauzia P
Widita, Rena
Budi, Wahyu S
Sutanto, Heri
Adi, Kusworo
Fujibuchi, Toshioh
Dougherty, Geoff
author_facet Anam, Choirul
Arif, Idam
Haryanto, Freddy
Lestari, Fauzia P
Widita, Rena
Budi, Wahyu S
Sutanto, Heri
Adi, Kusworo
Fujibuchi, Toshioh
Dougherty, Geoff
author_sort Anam, Choirul
collection PubMed
description BACKGROUND: It is necessary to have an automated noise measurement system working accurately to optimize dose in computerized tomography (CT) examinations. OBJECTIVE: This study aims to develop an algorithm to automate noise measurement that can be implemented in CT images of all body regions. MATERIALS AND METHODS: In this retrospective study, our automated noise measurement method consists of three steps as follows: the first is segmenting the image of the patient. The second is developing a standard deviation (SD) map by calculating the SD value for each pixel with a sliding window operation. The third step is estimating the noise as the smallest SD from the SD map. The proposed method was applied to the images of a homogenous phantom and a full body adult anthropomorphic phantom, and retrospectively applied to 27 abdominal images of patients. RESULTS: For a homogeneous phantom, the noises calculated using our proposed and previous algorithms have a linear correlation with R(2) = 0.997. It is found that the noise magnitude closely follows the magnitude of the water equivalent diameter (D(w)) in all body regions. The proposed algorithm is able to distinguish the noise magnitude due to variations in tube currents and different noise suppression techniques such as strong, standard, mild, and weak ones in a reconstructed image using the AIDR 3D algorithm. CONCLUSION: An automated noise calculation has been proposed and successfully implemented in all body regions. It is not only accurate and easy to implement but also not influenced by the subjectivity of user.
format Online
Article
Text
id pubmed-8064134
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-80641342021-04-30 An Improved Method of Automated Noise Measurement System in CT Images Anam, Choirul Arif, Idam Haryanto, Freddy Lestari, Fauzia P Widita, Rena Budi, Wahyu S Sutanto, Heri Adi, Kusworo Fujibuchi, Toshioh Dougherty, Geoff J Biomed Phys Eng Original Article BACKGROUND: It is necessary to have an automated noise measurement system working accurately to optimize dose in computerized tomography (CT) examinations. OBJECTIVE: This study aims to develop an algorithm to automate noise measurement that can be implemented in CT images of all body regions. MATERIALS AND METHODS: In this retrospective study, our automated noise measurement method consists of three steps as follows: the first is segmenting the image of the patient. The second is developing a standard deviation (SD) map by calculating the SD value for each pixel with a sliding window operation. The third step is estimating the noise as the smallest SD from the SD map. The proposed method was applied to the images of a homogenous phantom and a full body adult anthropomorphic phantom, and retrospectively applied to 27 abdominal images of patients. RESULTS: For a homogeneous phantom, the noises calculated using our proposed and previous algorithms have a linear correlation with R(2) = 0.997. It is found that the noise magnitude closely follows the magnitude of the water equivalent diameter (D(w)) in all body regions. The proposed algorithm is able to distinguish the noise magnitude due to variations in tube currents and different noise suppression techniques such as strong, standard, mild, and weak ones in a reconstructed image using the AIDR 3D algorithm. CONCLUSION: An automated noise calculation has been proposed and successfully implemented in all body regions. It is not only accurate and easy to implement but also not influenced by the subjectivity of user. Shiraz University of Medical Sciences 2021-04-01 /pmc/articles/PMC8064134/ /pubmed/33937124 http://dx.doi.org/10.31661/jbpe.v0i0.1198 Text en Copyright: © Journal of Biomedical Physics and Engineering https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 Unported License, ( http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Anam, Choirul
Arif, Idam
Haryanto, Freddy
Lestari, Fauzia P
Widita, Rena
Budi, Wahyu S
Sutanto, Heri
Adi, Kusworo
Fujibuchi, Toshioh
Dougherty, Geoff
An Improved Method of Automated Noise Measurement System in CT Images
title An Improved Method of Automated Noise Measurement System in CT Images
title_full An Improved Method of Automated Noise Measurement System in CT Images
title_fullStr An Improved Method of Automated Noise Measurement System in CT Images
title_full_unstemmed An Improved Method of Automated Noise Measurement System in CT Images
title_short An Improved Method of Automated Noise Measurement System in CT Images
title_sort improved method of automated noise measurement system in ct images
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8064134/
https://www.ncbi.nlm.nih.gov/pubmed/33937124
http://dx.doi.org/10.31661/jbpe.v0i0.1198
work_keys_str_mv AT anamchoirul animprovedmethodofautomatednoisemeasurementsysteminctimages
AT arifidam animprovedmethodofautomatednoisemeasurementsysteminctimages
AT haryantofreddy animprovedmethodofautomatednoisemeasurementsysteminctimages
AT lestarifauziap animprovedmethodofautomatednoisemeasurementsysteminctimages
AT widitarena animprovedmethodofautomatednoisemeasurementsysteminctimages
AT budiwahyus animprovedmethodofautomatednoisemeasurementsysteminctimages
AT sutantoheri animprovedmethodofautomatednoisemeasurementsysteminctimages
AT adikusworo animprovedmethodofautomatednoisemeasurementsysteminctimages
AT fujibuchitoshioh animprovedmethodofautomatednoisemeasurementsysteminctimages
AT doughertygeoff animprovedmethodofautomatednoisemeasurementsysteminctimages
AT anamchoirul improvedmethodofautomatednoisemeasurementsysteminctimages
AT arifidam improvedmethodofautomatednoisemeasurementsysteminctimages
AT haryantofreddy improvedmethodofautomatednoisemeasurementsysteminctimages
AT lestarifauziap improvedmethodofautomatednoisemeasurementsysteminctimages
AT widitarena improvedmethodofautomatednoisemeasurementsysteminctimages
AT budiwahyus improvedmethodofautomatednoisemeasurementsysteminctimages
AT sutantoheri improvedmethodofautomatednoisemeasurementsysteminctimages
AT adikusworo improvedmethodofautomatednoisemeasurementsysteminctimages
AT fujibuchitoshioh improvedmethodofautomatednoisemeasurementsysteminctimages
AT doughertygeoff improvedmethodofautomatednoisemeasurementsysteminctimages