Cargando…
Theoretical Analysis of Constant Voltage Mode Membrane Capacitive Deionization for Water Softening
Water softening is desirable to reduce scaling in water infrastructure and to meet industrial water quality needs and consumer preferences. Membrane capacitive deionization (MCDI) can preferentially adsorb divalent ions including calcium and magnesium and thus may be an attractive water softening te...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8064386/ https://www.ncbi.nlm.nih.gov/pubmed/33805237 http://dx.doi.org/10.3390/membranes11040231 |
_version_ | 1783682124680790016 |
---|---|
author | Zhang, Xin Reible, Danny |
author_facet | Zhang, Xin Reible, Danny |
author_sort | Zhang, Xin |
collection | PubMed |
description | Water softening is desirable to reduce scaling in water infrastructure and to meet industrial water quality needs and consumer preferences. Membrane capacitive deionization (MCDI) can preferentially adsorb divalent ions including calcium and magnesium and thus may be an attractive water softening technology. In this work, a process model incorporating ion exclusion effects was applied to investigate water softening performance including ion selectivity, ion removal efficiency and energy consumption in a constant voltage (CV) mode MCDI. Trade-offs between the simulated Ca(2+) selectivity and Ca(2+) removal efficiency under varying applied voltage and varying initial concentration ratio of Na(+) to Ca(2+) were observed. A cut-off CV mode, which was operated to maximize Ca(2+) removal efficiency per cycle, was found to lead to a specific energy consumption (SEC) of 0.061 kWh/mole removed Ca(2+) for partially softening industrial water and 0.077 kWh/m(3) removed Ca(2+) for slightly softening tap water at a water recovery of 0.5. This is an order of magnitude less than reported values for other softening techniques. MCDI should be explored more fully as an energy efficient means of water softening. |
format | Online Article Text |
id | pubmed-8064386 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80643862021-04-24 Theoretical Analysis of Constant Voltage Mode Membrane Capacitive Deionization for Water Softening Zhang, Xin Reible, Danny Membranes (Basel) Article Water softening is desirable to reduce scaling in water infrastructure and to meet industrial water quality needs and consumer preferences. Membrane capacitive deionization (MCDI) can preferentially adsorb divalent ions including calcium and magnesium and thus may be an attractive water softening technology. In this work, a process model incorporating ion exclusion effects was applied to investigate water softening performance including ion selectivity, ion removal efficiency and energy consumption in a constant voltage (CV) mode MCDI. Trade-offs between the simulated Ca(2+) selectivity and Ca(2+) removal efficiency under varying applied voltage and varying initial concentration ratio of Na(+) to Ca(2+) were observed. A cut-off CV mode, which was operated to maximize Ca(2+) removal efficiency per cycle, was found to lead to a specific energy consumption (SEC) of 0.061 kWh/mole removed Ca(2+) for partially softening industrial water and 0.077 kWh/m(3) removed Ca(2+) for slightly softening tap water at a water recovery of 0.5. This is an order of magnitude less than reported values for other softening techniques. MCDI should be explored more fully as an energy efficient means of water softening. MDPI 2021-03-24 /pmc/articles/PMC8064386/ /pubmed/33805237 http://dx.doi.org/10.3390/membranes11040231 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ). |
spellingShingle | Article Zhang, Xin Reible, Danny Theoretical Analysis of Constant Voltage Mode Membrane Capacitive Deionization for Water Softening |
title | Theoretical Analysis of Constant Voltage Mode Membrane Capacitive Deionization for Water Softening |
title_full | Theoretical Analysis of Constant Voltage Mode Membrane Capacitive Deionization for Water Softening |
title_fullStr | Theoretical Analysis of Constant Voltage Mode Membrane Capacitive Deionization for Water Softening |
title_full_unstemmed | Theoretical Analysis of Constant Voltage Mode Membrane Capacitive Deionization for Water Softening |
title_short | Theoretical Analysis of Constant Voltage Mode Membrane Capacitive Deionization for Water Softening |
title_sort | theoretical analysis of constant voltage mode membrane capacitive deionization for water softening |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8064386/ https://www.ncbi.nlm.nih.gov/pubmed/33805237 http://dx.doi.org/10.3390/membranes11040231 |
work_keys_str_mv | AT zhangxin theoreticalanalysisofconstantvoltagemodemembranecapacitivedeionizationforwatersoftening AT reibledanny theoreticalanalysisofconstantvoltagemodemembranecapacitivedeionizationforwatersoftening |