Cargando…
Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements
In recent years, the undeclared presence of various anabolic androgenic steroids (AAS) in commercial supplements has been confirmed. This fact can be a potential threat to all athletes using these supplements, and therefore, there is of increased interest in the implementation of rapid methods for t...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8065520/ https://www.ncbi.nlm.nih.gov/pubmed/33915816 http://dx.doi.org/10.3390/foods10040741 |
_version_ | 1783682360665964544 |
---|---|
author | Holubová, Barbora Kubešová, Pavla Huml, Lukáš Vlach, Miroslav Lapčík, Oldřich Jurášek, Michal Fukal, Ladislav |
author_facet | Holubová, Barbora Kubešová, Pavla Huml, Lukáš Vlach, Miroslav Lapčík, Oldřich Jurášek, Michal Fukal, Ladislav |
author_sort | Holubová, Barbora |
collection | PubMed |
description | In recent years, the undeclared presence of various anabolic androgenic steroids (AAS) in commercial supplements has been confirmed. This fact can be a potential threat to all athletes using these supplements, and therefore, there is of increased interest in the implementation of rapid methods for the detection of AAS. The presented study describes the development of an immunostrip test for the detection of multiple 17α-methylated AAS based on direct and indirect competitive principle using gold nanoparticles as a label. As a capture reagent on test lines conjugated stanazolol to rabbit serum albumin (RSA/ST-3) was used, the intensity of color formed in the test line of the AAS-positive sample was visually distinguishable from that of negative sample within 10 min. The optimized closed direct and indirect format of the test provided a similar visual detection limit (0.7 and 0.9 ng/mL, respectively). The most commonly orally abused AAS (17α-methyltestosterone, methandienone, methyldihydrotestosterone, oxandrolone and oxymetholone) showed a strong cross-reaction. Developed immunostrips were successfully applied to analysis of artificially contaminated dietary supplements with 17α-methylated AASs. The developed immunostrips offer potential as a useful user-friendly method for capturing suspicious dietary supplement samples with different contents of AAS at levels far below the usually used concentrations of AAS. |
format | Online Article Text |
id | pubmed-8065520 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80655202021-04-25 Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements Holubová, Barbora Kubešová, Pavla Huml, Lukáš Vlach, Miroslav Lapčík, Oldřich Jurášek, Michal Fukal, Ladislav Foods Article In recent years, the undeclared presence of various anabolic androgenic steroids (AAS) in commercial supplements has been confirmed. This fact can be a potential threat to all athletes using these supplements, and therefore, there is of increased interest in the implementation of rapid methods for the detection of AAS. The presented study describes the development of an immunostrip test for the detection of multiple 17α-methylated AAS based on direct and indirect competitive principle using gold nanoparticles as a label. As a capture reagent on test lines conjugated stanazolol to rabbit serum albumin (RSA/ST-3) was used, the intensity of color formed in the test line of the AAS-positive sample was visually distinguishable from that of negative sample within 10 min. The optimized closed direct and indirect format of the test provided a similar visual detection limit (0.7 and 0.9 ng/mL, respectively). The most commonly orally abused AAS (17α-methyltestosterone, methandienone, methyldihydrotestosterone, oxandrolone and oxymetholone) showed a strong cross-reaction. Developed immunostrips were successfully applied to analysis of artificially contaminated dietary supplements with 17α-methylated AASs. The developed immunostrips offer potential as a useful user-friendly method for capturing suspicious dietary supplement samples with different contents of AAS at levels far below the usually used concentrations of AAS. MDPI 2021-04-01 /pmc/articles/PMC8065520/ /pubmed/33915816 http://dx.doi.org/10.3390/foods10040741 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Holubová, Barbora Kubešová, Pavla Huml, Lukáš Vlach, Miroslav Lapčík, Oldřich Jurášek, Michal Fukal, Ladislav Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements |
title | Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements |
title_full | Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements |
title_fullStr | Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements |
title_full_unstemmed | Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements |
title_short | Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements |
title_sort | tailor-made immunochromatographic test for the detection of multiple 17α-methylated anabolics in dietary supplements |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8065520/ https://www.ncbi.nlm.nih.gov/pubmed/33915816 http://dx.doi.org/10.3390/foods10040741 |
work_keys_str_mv | AT holubovabarbora tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements AT kubesovapavla tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements AT humllukas tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements AT vlachmiroslav tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements AT lapcikoldrich tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements AT jurasekmichal tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements AT fukalladislav tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements |