Cargando…

Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements

In recent years, the undeclared presence of various anabolic androgenic steroids (AAS) in commercial supplements has been confirmed. This fact can be a potential threat to all athletes using these supplements, and therefore, there is of increased interest in the implementation of rapid methods for t...

Descripción completa

Detalles Bibliográficos
Autores principales: Holubová, Barbora, Kubešová, Pavla, Huml, Lukáš, Vlach, Miroslav, Lapčík, Oldřich, Jurášek, Michal, Fukal, Ladislav
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8065520/
https://www.ncbi.nlm.nih.gov/pubmed/33915816
http://dx.doi.org/10.3390/foods10040741
_version_ 1783682360665964544
author Holubová, Barbora
Kubešová, Pavla
Huml, Lukáš
Vlach, Miroslav
Lapčík, Oldřich
Jurášek, Michal
Fukal, Ladislav
author_facet Holubová, Barbora
Kubešová, Pavla
Huml, Lukáš
Vlach, Miroslav
Lapčík, Oldřich
Jurášek, Michal
Fukal, Ladislav
author_sort Holubová, Barbora
collection PubMed
description In recent years, the undeclared presence of various anabolic androgenic steroids (AAS) in commercial supplements has been confirmed. This fact can be a potential threat to all athletes using these supplements, and therefore, there is of increased interest in the implementation of rapid methods for the detection of AAS. The presented study describes the development of an immunostrip test for the detection of multiple 17α-methylated AAS based on direct and indirect competitive principle using gold nanoparticles as a label. As a capture reagent on test lines conjugated stanazolol to rabbit serum albumin (RSA/ST-3) was used, the intensity of color formed in the test line of the AAS-positive sample was visually distinguishable from that of negative sample within 10 min. The optimized closed direct and indirect format of the test provided a similar visual detection limit (0.7 and 0.9 ng/mL, respectively). The most commonly orally abused AAS (17α-methyltestosterone, methandienone, methyldihydrotestosterone, oxandrolone and oxymetholone) showed a strong cross-reaction. Developed immunostrips were successfully applied to analysis of artificially contaminated dietary supplements with 17α-methylated AASs. The developed immunostrips offer potential as a useful user-friendly method for capturing suspicious dietary supplement samples with different contents of AAS at levels far below the usually used concentrations of AAS.
format Online
Article
Text
id pubmed-8065520
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80655202021-04-25 Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements Holubová, Barbora Kubešová, Pavla Huml, Lukáš Vlach, Miroslav Lapčík, Oldřich Jurášek, Michal Fukal, Ladislav Foods Article In recent years, the undeclared presence of various anabolic androgenic steroids (AAS) in commercial supplements has been confirmed. This fact can be a potential threat to all athletes using these supplements, and therefore, there is of increased interest in the implementation of rapid methods for the detection of AAS. The presented study describes the development of an immunostrip test for the detection of multiple 17α-methylated AAS based on direct and indirect competitive principle using gold nanoparticles as a label. As a capture reagent on test lines conjugated stanazolol to rabbit serum albumin (RSA/ST-3) was used, the intensity of color formed in the test line of the AAS-positive sample was visually distinguishable from that of negative sample within 10 min. The optimized closed direct and indirect format of the test provided a similar visual detection limit (0.7 and 0.9 ng/mL, respectively). The most commonly orally abused AAS (17α-methyltestosterone, methandienone, methyldihydrotestosterone, oxandrolone and oxymetholone) showed a strong cross-reaction. Developed immunostrips were successfully applied to analysis of artificially contaminated dietary supplements with 17α-methylated AASs. The developed immunostrips offer potential as a useful user-friendly method for capturing suspicious dietary supplement samples with different contents of AAS at levels far below the usually used concentrations of AAS. MDPI 2021-04-01 /pmc/articles/PMC8065520/ /pubmed/33915816 http://dx.doi.org/10.3390/foods10040741 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Holubová, Barbora
Kubešová, Pavla
Huml, Lukáš
Vlach, Miroslav
Lapčík, Oldřich
Jurášek, Michal
Fukal, Ladislav
Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements
title Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements
title_full Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements
title_fullStr Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements
title_full_unstemmed Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements
title_short Tailor-Made Immunochromatographic Test for the Detection of Multiple 17α-Methylated Anabolics in Dietary Supplements
title_sort tailor-made immunochromatographic test for the detection of multiple 17α-methylated anabolics in dietary supplements
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8065520/
https://www.ncbi.nlm.nih.gov/pubmed/33915816
http://dx.doi.org/10.3390/foods10040741
work_keys_str_mv AT holubovabarbora tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements
AT kubesovapavla tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements
AT humllukas tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements
AT vlachmiroslav tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements
AT lapcikoldrich tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements
AT jurasekmichal tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements
AT fukalladislav tailormadeimmunochromatographictestforthedetectionofmultiple17amethylatedanabolicsindietarysupplements