Cargando…

The Accuracy of On-Call CT Reporting in Teleradiology Networks in Comparison to In-House Reporting

(1) Background: We aimed to compare the accuracy of after-hours CT reports created in a traditional in-house setting versus a teleradiology setting by assessing the discrepancy rates between preliminary and final reports. (2) Methods: We conducted a prospective study to determine the number and seve...

Descripción completa

Detalles Bibliográficos
Autores principales: Storjohann, Svea, Kirsch, Michael, Rosenberg, Britta, Rosenberg, Christian, Lange, Sandra, Syperek, Annika, Schweikhard, Frank Philipp, Hosten, Norbert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8065948/
https://www.ncbi.nlm.nih.gov/pubmed/33916229
http://dx.doi.org/10.3390/healthcare9040405
_version_ 1783682460178972672
author Storjohann, Svea
Kirsch, Michael
Rosenberg, Britta
Rosenberg, Christian
Lange, Sandra
Syperek, Annika
Schweikhard, Frank Philipp
Hosten, Norbert
author_facet Storjohann, Svea
Kirsch, Michael
Rosenberg, Britta
Rosenberg, Christian
Lange, Sandra
Syperek, Annika
Schweikhard, Frank Philipp
Hosten, Norbert
author_sort Storjohann, Svea
collection PubMed
description (1) Background: We aimed to compare the accuracy of after-hours CT reports created in a traditional in-house setting versus a teleradiology setting by assessing the discrepancy rates between preliminary and final reports. (2) Methods: We conducted a prospective study to determine the number and severity of discrepancies between preliminary and final reports for 7761 consecutive after-hours CT scans collected over a 21-month period. CT exams were performed during on-call hours and were proofread by an attending the next day. Discrepancies between preliminary and gold-standard reports were evaluated by two senior attending radiologists, and differences in rates were assessed for statistical significance. (3) Results: A total of 7209 reports were included in the analysis. Discrepancies occurred in 1215/7209 cases (17%). Among these, 433/7209 reports (6%) showed clinically important differences between the preliminary and final reports. A total of 335/5509 of them were in-house reports (6.1%), and 98/1700 were teleradiology reports (5.8%). The relative frequencies of report changes were not significantly higher in teleradiology. (4) Conclusions: The accuracy of teleradiology reports was not inferior to that of in-house reports, with very similar clinically important differences rates found in both reporting situations.
format Online
Article
Text
id pubmed-8065948
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80659482021-04-25 The Accuracy of On-Call CT Reporting in Teleradiology Networks in Comparison to In-House Reporting Storjohann, Svea Kirsch, Michael Rosenberg, Britta Rosenberg, Christian Lange, Sandra Syperek, Annika Schweikhard, Frank Philipp Hosten, Norbert Healthcare (Basel) Article (1) Background: We aimed to compare the accuracy of after-hours CT reports created in a traditional in-house setting versus a teleradiology setting by assessing the discrepancy rates between preliminary and final reports. (2) Methods: We conducted a prospective study to determine the number and severity of discrepancies between preliminary and final reports for 7761 consecutive after-hours CT scans collected over a 21-month period. CT exams were performed during on-call hours and were proofread by an attending the next day. Discrepancies between preliminary and gold-standard reports were evaluated by two senior attending radiologists, and differences in rates were assessed for statistical significance. (3) Results: A total of 7209 reports were included in the analysis. Discrepancies occurred in 1215/7209 cases (17%). Among these, 433/7209 reports (6%) showed clinically important differences between the preliminary and final reports. A total of 335/5509 of them were in-house reports (6.1%), and 98/1700 were teleradiology reports (5.8%). The relative frequencies of report changes were not significantly higher in teleradiology. (4) Conclusions: The accuracy of teleradiology reports was not inferior to that of in-house reports, with very similar clinically important differences rates found in both reporting situations. MDPI 2021-04-01 /pmc/articles/PMC8065948/ /pubmed/33916229 http://dx.doi.org/10.3390/healthcare9040405 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Storjohann, Svea
Kirsch, Michael
Rosenberg, Britta
Rosenberg, Christian
Lange, Sandra
Syperek, Annika
Schweikhard, Frank Philipp
Hosten, Norbert
The Accuracy of On-Call CT Reporting in Teleradiology Networks in Comparison to In-House Reporting
title The Accuracy of On-Call CT Reporting in Teleradiology Networks in Comparison to In-House Reporting
title_full The Accuracy of On-Call CT Reporting in Teleradiology Networks in Comparison to In-House Reporting
title_fullStr The Accuracy of On-Call CT Reporting in Teleradiology Networks in Comparison to In-House Reporting
title_full_unstemmed The Accuracy of On-Call CT Reporting in Teleradiology Networks in Comparison to In-House Reporting
title_short The Accuracy of On-Call CT Reporting in Teleradiology Networks in Comparison to In-House Reporting
title_sort accuracy of on-call ct reporting in teleradiology networks in comparison to in-house reporting
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8065948/
https://www.ncbi.nlm.nih.gov/pubmed/33916229
http://dx.doi.org/10.3390/healthcare9040405
work_keys_str_mv AT storjohannsvea theaccuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT kirschmichael theaccuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT rosenbergbritta theaccuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT rosenbergchristian theaccuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT langesandra theaccuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT syperekannika theaccuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT schweikhardfrankphilipp theaccuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT hostennorbert theaccuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT storjohannsvea accuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT kirschmichael accuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT rosenbergbritta accuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT rosenbergchristian accuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT langesandra accuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT syperekannika accuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT schweikhardfrankphilipp accuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting
AT hostennorbert accuracyofoncallctreportinginteleradiologynetworksincomparisontoinhousereporting