Investigation of Cylindrical Piezoelectric and Specific Multi-Channel Circular MEMS-Transducer Array Resonator of Ultrasonic Ablation

Background: A cylindrical piezoelectric element and a specific multi-channel circular microelectromechanical systems (MEMS)-transducer array of ultrasonic system were used for ultrasonic energy generation and ablation. A relatively long time is required for the heat to be conducted to the target pos...

Descripción completa

Detalles Bibliográficos
Autores principales: Liou, Jian-Chiun, Peng, Chih-Wei, Chen, Zhen-Xi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8066577/
https://www.ncbi.nlm.nih.gov/pubmed/33808313
http://dx.doi.org/10.3390/mi12040371
_version_ 1783682601535406080
author Liou, Jian-Chiun
Peng, Chih-Wei
Chen, Zhen-Xi
author_facet Liou, Jian-Chiun
Peng, Chih-Wei
Chen, Zhen-Xi
author_sort Liou, Jian-Chiun
collection PubMed
description Background: A cylindrical piezoelectric element and a specific multi-channel circular microelectromechanical systems (MEMS)-transducer array of ultrasonic system were used for ultrasonic energy generation and ablation. A relatively long time is required for the heat to be conducted to the target position. Ultrasound thermal therapy has great potential for treating deep hyperplastic tissues and tumors, such as breast cancer and liver tumors. Methods: Ultrasound ablation technology produces thermal energy by heating the surface of a target, and the heat gradually penetrates to the target’s interior. Beamforming was performed to observe energy distribution. A resonance method was used to generate ablation energy for verification. Energy was generated according to the coordinates of geometric graph positions to reach the ablation temperature. Results: The mean resonance frequency of Channels 1–8 was 2.5 MHz, and the cylindrical piezoelectric ultrasonic element of Channel A was 4.2546 Ω at 5.7946 MHz. High-intensity ultrasound has gradually been applied in clinical treatment. Widely adopted, ultrasonic hyperthermia involves the use of high-intensity ultrasound to heat tissues at 42–45 °C for 30–60 min. Conclusion: In the ultrasonic energy method, when the target position reaches a temperature that significantly reduces the cell viability (46.9 °C), protein surface modification occurs on the surface of the target.
format Online
Article
Text
id pubmed-8066577
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80665772021-04-25 Investigation of Cylindrical Piezoelectric and Specific Multi-Channel Circular MEMS-Transducer Array Resonator of Ultrasonic Ablation Liou, Jian-Chiun Peng, Chih-Wei Chen, Zhen-Xi Micromachines (Basel) Article Background: A cylindrical piezoelectric element and a specific multi-channel circular microelectromechanical systems (MEMS)-transducer array of ultrasonic system were used for ultrasonic energy generation and ablation. A relatively long time is required for the heat to be conducted to the target position. Ultrasound thermal therapy has great potential for treating deep hyperplastic tissues and tumors, such as breast cancer and liver tumors. Methods: Ultrasound ablation technology produces thermal energy by heating the surface of a target, and the heat gradually penetrates to the target’s interior. Beamforming was performed to observe energy distribution. A resonance method was used to generate ablation energy for verification. Energy was generated according to the coordinates of geometric graph positions to reach the ablation temperature. Results: The mean resonance frequency of Channels 1–8 was 2.5 MHz, and the cylindrical piezoelectric ultrasonic element of Channel A was 4.2546 Ω at 5.7946 MHz. High-intensity ultrasound has gradually been applied in clinical treatment. Widely adopted, ultrasonic hyperthermia involves the use of high-intensity ultrasound to heat tissues at 42–45 °C for 30–60 min. Conclusion: In the ultrasonic energy method, when the target position reaches a temperature that significantly reduces the cell viability (46.9 °C), protein surface modification occurs on the surface of the target. MDPI 2021-03-30 /pmc/articles/PMC8066577/ /pubmed/33808313 http://dx.doi.org/10.3390/mi12040371 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liou, Jian-Chiun
Peng, Chih-Wei
Chen, Zhen-Xi
Investigation of Cylindrical Piezoelectric and Specific Multi-Channel Circular MEMS-Transducer Array Resonator of Ultrasonic Ablation
title Investigation of Cylindrical Piezoelectric and Specific Multi-Channel Circular MEMS-Transducer Array Resonator of Ultrasonic Ablation
title_full Investigation of Cylindrical Piezoelectric and Specific Multi-Channel Circular MEMS-Transducer Array Resonator of Ultrasonic Ablation
title_fullStr Investigation of Cylindrical Piezoelectric and Specific Multi-Channel Circular MEMS-Transducer Array Resonator of Ultrasonic Ablation
title_full_unstemmed Investigation of Cylindrical Piezoelectric and Specific Multi-Channel Circular MEMS-Transducer Array Resonator of Ultrasonic Ablation
title_short Investigation of Cylindrical Piezoelectric and Specific Multi-Channel Circular MEMS-Transducer Array Resonator of Ultrasonic Ablation
title_sort investigation of cylindrical piezoelectric and specific multi-channel circular mems-transducer array resonator of ultrasonic ablation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8066577/
https://www.ncbi.nlm.nih.gov/pubmed/33808313
http://dx.doi.org/10.3390/mi12040371
work_keys_str_mv AT lioujianchiun investigationofcylindricalpiezoelectricandspecificmultichannelcircularmemstransducerarrayresonatorofultrasonicablation
AT pengchihwei investigationofcylindricalpiezoelectricandspecificmultichannelcircularmemstransducerarrayresonatorofultrasonicablation
AT chenzhenxi investigationofcylindricalpiezoelectricandspecificmultichannelcircularmemstransducerarrayresonatorofultrasonicablation