Cargando…
Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging
Positron emission tomography (PET) is a functional non-invasive imaging modality that uses radioactive substances (radiotracers) to measure changes in metabolic processes. Advances in scanner technology and data acquisition in the last decade have led to the development of more sophisticated PET dev...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8068167/ https://www.ncbi.nlm.nih.gov/pubmed/33917742 http://dx.doi.org/10.3390/s21082608 |
_version_ | 1783682972309782528 |
---|---|
author | Espinós-Morató, Héctor Cascales-Picó, David Vergara, Marina Hernández-Martínez, Ángel Benlloch Baviera, José María Rodríguez-Álvarez, María José |
author_facet | Espinós-Morató, Héctor Cascales-Picó, David Vergara, Marina Hernández-Martínez, Ángel Benlloch Baviera, José María Rodríguez-Álvarez, María José |
author_sort | Espinós-Morató, Héctor |
collection | PubMed |
description | Positron emission tomography (PET) is a functional non-invasive imaging modality that uses radioactive substances (radiotracers) to measure changes in metabolic processes. Advances in scanner technology and data acquisition in the last decade have led to the development of more sophisticated PET devices with good spatial resolution (1–3 mm of full width at half maximum (FWHM)). However, there are involuntary motions produced by the patient inside the scanner that lead to image degradation and potentially to a misdiagnosis. The adverse effect of the motion in the reconstructed image increases as the spatial resolution of the current scanners continues improving. In order to correct this effect, motion correction techniques are becoming increasingly popular and further studied. This work presents a simulation study of an image motion correction using a frame-based algorithm. The method is able to cut the acquired data from the scanner in frames, taking into account the size of the object of study. This approach allows working with low statistical information without losing image quality. The frames are later registered using spatio-temporal registration developed in a multi-level way. To validate these results, several performance tests are applied to a set of simulated moving phantoms. The results obtained show that the method minimizes the intra-frame motion, improves the signal intensity over the background in comparison with other literature methods, produces excellent values of similarity with the ground-truth (static) image and is able to find a limit in the patient-injected dose when some prior knowledge of the lesion is present. |
format | Online Article Text |
id | pubmed-8068167 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80681672021-04-25 Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging Espinós-Morató, Héctor Cascales-Picó, David Vergara, Marina Hernández-Martínez, Ángel Benlloch Baviera, José María Rodríguez-Álvarez, María José Sensors (Basel) Article Positron emission tomography (PET) is a functional non-invasive imaging modality that uses radioactive substances (radiotracers) to measure changes in metabolic processes. Advances in scanner technology and data acquisition in the last decade have led to the development of more sophisticated PET devices with good spatial resolution (1–3 mm of full width at half maximum (FWHM)). However, there are involuntary motions produced by the patient inside the scanner that lead to image degradation and potentially to a misdiagnosis. The adverse effect of the motion in the reconstructed image increases as the spatial resolution of the current scanners continues improving. In order to correct this effect, motion correction techniques are becoming increasingly popular and further studied. This work presents a simulation study of an image motion correction using a frame-based algorithm. The method is able to cut the acquired data from the scanner in frames, taking into account the size of the object of study. This approach allows working with low statistical information without losing image quality. The frames are later registered using spatio-temporal registration developed in a multi-level way. To validate these results, several performance tests are applied to a set of simulated moving phantoms. The results obtained show that the method minimizes the intra-frame motion, improves the signal intensity over the background in comparison with other literature methods, produces excellent values of similarity with the ground-truth (static) image and is able to find a limit in the patient-injected dose when some prior knowledge of the lesion is present. MDPI 2021-04-08 /pmc/articles/PMC8068167/ /pubmed/33917742 http://dx.doi.org/10.3390/s21082608 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Espinós-Morató, Héctor Cascales-Picó, David Vergara, Marina Hernández-Martínez, Ángel Benlloch Baviera, José María Rodríguez-Álvarez, María José Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging |
title | Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging |
title_full | Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging |
title_fullStr | Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging |
title_full_unstemmed | Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging |
title_short | Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging |
title_sort | simulation study of a frame-based motion correction algorithm for positron emission imaging |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8068167/ https://www.ncbi.nlm.nih.gov/pubmed/33917742 http://dx.doi.org/10.3390/s21082608 |
work_keys_str_mv | AT espinosmoratohector simulationstudyofaframebasedmotioncorrectionalgorithmforpositronemissionimaging AT cascalespicodavid simulationstudyofaframebasedmotioncorrectionalgorithmforpositronemissionimaging AT vergaramarina simulationstudyofaframebasedmotioncorrectionalgorithmforpositronemissionimaging AT hernandezmartinezangel simulationstudyofaframebasedmotioncorrectionalgorithmforpositronemissionimaging AT benllochbavierajosemaria simulationstudyofaframebasedmotioncorrectionalgorithmforpositronemissionimaging AT rodriguezalvarezmariajose simulationstudyofaframebasedmotioncorrectionalgorithmforpositronemissionimaging |