Cargando…
Vibration Exposure and Transmissibility on Dentist’s Anatomy: A Study of Micro Motors and Air-Turbines
The use of dental hand pieces endanger dentists to vibration exposure as they are subjected to very high amplitude and vibration frequency. This paper has envisaged a comparative analysis of vibration amplitudes and transmissibility during idling and drilling with micro motor (MM) and air-turbine (A...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8069559/ https://www.ncbi.nlm.nih.gov/pubmed/33924408 http://dx.doi.org/10.3390/ijerph18084084 |
_version_ | 1783683265689812992 |
---|---|
author | Banga, Harish Kumar Goel, Pankaj Kumar, Raman Kumar, Vikas Kalra, Parveen Singh, Sehijpal Singh, Sunpreet Prakash, Chander Pruncu, Catalin |
author_facet | Banga, Harish Kumar Goel, Pankaj Kumar, Raman Kumar, Vikas Kalra, Parveen Singh, Sehijpal Singh, Sunpreet Prakash, Chander Pruncu, Catalin |
author_sort | Banga, Harish Kumar |
collection | PubMed |
description | The use of dental hand pieces endanger dentists to vibration exposure as they are subjected to very high amplitude and vibration frequency. This paper has envisaged a comparative analysis of vibration amplitudes and transmissibility during idling and drilling with micro motor (MM) and air-turbine (AT) hand pieces. The study aims to identify the mean difference in vibration amplitudes during idling, explore different grasp forces while drilling with irrigant injection by the dentist, and various vibration transmission of these hand pieces. The study utilized 22 separate frequency resonances on two new and eight used MMs and two new and eight used ATs of different brands by observing the investigator at 16 different dentist clinics. The study adopted a descriptive research design with non–probability sampling techniques for selecting dentists and hand pieces. Statistical methods like Levene Test of Homogeneity, Welch ANOVA, independent t-test, and Games–Howell test were utilized with SPSS version 22 and MS-Excel. The results reveal that vibration amplitudes and vibration transmissibility when measured at position 2 are higher than in another position 1. Vibrations during idling for used MMs are more than AT hand pieces, and the used MM (MUD) and used AT (AUA) hand pieces differ due to their obsolescence and over-usage. Vibration amplitudes increase every time with the tightening of grasping of the hand piece. Vibration amplitudes for each grasping style of MM hand piece differ from all other grasping styles of AT hand pieces. Routine exposure to consistent vibrations has ill physical, mental, and psychological effects on dentists. The used hand pieces more hazardous as compared to newer ones. The study suggests that these hand pieces must be replaced periodically, sufficient to break between two operations, especially after every hand piece usage. Hence, the present research work can be further extended by creating some control groups among dentists and then studying the vibration amplitude exposure of various dental hand pieces and subsequent transmissibility to their body parts. |
format | Online Article Text |
id | pubmed-8069559 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80695592021-04-26 Vibration Exposure and Transmissibility on Dentist’s Anatomy: A Study of Micro Motors and Air-Turbines Banga, Harish Kumar Goel, Pankaj Kumar, Raman Kumar, Vikas Kalra, Parveen Singh, Sehijpal Singh, Sunpreet Prakash, Chander Pruncu, Catalin Int J Environ Res Public Health Article The use of dental hand pieces endanger dentists to vibration exposure as they are subjected to very high amplitude and vibration frequency. This paper has envisaged a comparative analysis of vibration amplitudes and transmissibility during idling and drilling with micro motor (MM) and air-turbine (AT) hand pieces. The study aims to identify the mean difference in vibration amplitudes during idling, explore different grasp forces while drilling with irrigant injection by the dentist, and various vibration transmission of these hand pieces. The study utilized 22 separate frequency resonances on two new and eight used MMs and two new and eight used ATs of different brands by observing the investigator at 16 different dentist clinics. The study adopted a descriptive research design with non–probability sampling techniques for selecting dentists and hand pieces. Statistical methods like Levene Test of Homogeneity, Welch ANOVA, independent t-test, and Games–Howell test were utilized with SPSS version 22 and MS-Excel. The results reveal that vibration amplitudes and vibration transmissibility when measured at position 2 are higher than in another position 1. Vibrations during idling for used MMs are more than AT hand pieces, and the used MM (MUD) and used AT (AUA) hand pieces differ due to their obsolescence and over-usage. Vibration amplitudes increase every time with the tightening of grasping of the hand piece. Vibration amplitudes for each grasping style of MM hand piece differ from all other grasping styles of AT hand pieces. Routine exposure to consistent vibrations has ill physical, mental, and psychological effects on dentists. The used hand pieces more hazardous as compared to newer ones. The study suggests that these hand pieces must be replaced periodically, sufficient to break between two operations, especially after every hand piece usage. Hence, the present research work can be further extended by creating some control groups among dentists and then studying the vibration amplitude exposure of various dental hand pieces and subsequent transmissibility to their body parts. MDPI 2021-04-13 /pmc/articles/PMC8069559/ /pubmed/33924408 http://dx.doi.org/10.3390/ijerph18084084 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Banga, Harish Kumar Goel, Pankaj Kumar, Raman Kumar, Vikas Kalra, Parveen Singh, Sehijpal Singh, Sunpreet Prakash, Chander Pruncu, Catalin Vibration Exposure and Transmissibility on Dentist’s Anatomy: A Study of Micro Motors and Air-Turbines |
title | Vibration Exposure and Transmissibility on Dentist’s Anatomy: A Study of Micro Motors and Air-Turbines |
title_full | Vibration Exposure and Transmissibility on Dentist’s Anatomy: A Study of Micro Motors and Air-Turbines |
title_fullStr | Vibration Exposure and Transmissibility on Dentist’s Anatomy: A Study of Micro Motors and Air-Turbines |
title_full_unstemmed | Vibration Exposure and Transmissibility on Dentist’s Anatomy: A Study of Micro Motors and Air-Turbines |
title_short | Vibration Exposure and Transmissibility on Dentist’s Anatomy: A Study of Micro Motors and Air-Turbines |
title_sort | vibration exposure and transmissibility on dentist’s anatomy: a study of micro motors and air-turbines |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8069559/ https://www.ncbi.nlm.nih.gov/pubmed/33924408 http://dx.doi.org/10.3390/ijerph18084084 |
work_keys_str_mv | AT bangaharishkumar vibrationexposureandtransmissibilityondentistsanatomyastudyofmicromotorsandairturbines AT goelpankaj vibrationexposureandtransmissibilityondentistsanatomyastudyofmicromotorsandairturbines AT kumarraman vibrationexposureandtransmissibilityondentistsanatomyastudyofmicromotorsandairturbines AT kumarvikas vibrationexposureandtransmissibilityondentistsanatomyastudyofmicromotorsandairturbines AT kalraparveen vibrationexposureandtransmissibilityondentistsanatomyastudyofmicromotorsandairturbines AT singhsehijpal vibrationexposureandtransmissibilityondentistsanatomyastudyofmicromotorsandairturbines AT singhsunpreet vibrationexposureandtransmissibilityondentistsanatomyastudyofmicromotorsandairturbines AT prakashchander vibrationexposureandtransmissibilityondentistsanatomyastudyofmicromotorsandairturbines AT pruncucatalin vibrationexposureandtransmissibilityondentistsanatomyastudyofmicromotorsandairturbines |