Cargando…
Individualised Timing of Radio-Guided Parathyroidectomy Using Multi-Phase SPECT/CT Increases In Vivo Sensitivity and Accuracy and Reduces Operating Time: A Randomised Clinical Trial
Background: Minimally invasive parathyroidectomy is the preferred treatment for primary hyperparathyroidism. Despite relatively accurate preoperative information, minimally invasive parathyroidectomy can be challenging, especially in the case of small and ectopic adenomas. Radio guidance aids in bot...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8070050/ https://www.ncbi.nlm.nih.gov/pubmed/33918800 http://dx.doi.org/10.3390/diagnostics11040677 |
_version_ | 1783683380031782912 |
---|---|
author | Formánek, Martin Dedek, Vladimír Koláček, Michal Havel, Martin Zeleník, Karol Komínek, Pavel |
author_facet | Formánek, Martin Dedek, Vladimír Koláček, Michal Havel, Martin Zeleník, Karol Komínek, Pavel |
author_sort | Formánek, Martin |
collection | PubMed |
description | Background: Minimally invasive parathyroidectomy is the preferred treatment for primary hyperparathyroidism. Despite relatively accurate preoperative information, minimally invasive parathyroidectomy can be challenging, especially in the case of small and ectopic adenomas. Radio guidance aids in both in vivo identification and ex vivo confirmation of adenoma. In vivo accuracy is currently not satisfactory. The present study evaluated whether a beneficial effect (increased sensitivity, specificity, accuracy) is obtained with individualised timing of minimally invasive radio-guided parathyroidectomy (MIRGP) using preoperative multi-phase 99mTc-MIBI single photon emission computed tomography (SPECT)/computed tomography (CT). Methods: This randomised clinical trial was conducted from May 2016 to January 2020 in a tertiary referral hospital. Adult patients with primary hyperparathyroidism sent for 99mTc-MIBI SPECT/CT were included consecutively and randomly assigned to conventional (dual-phase) SPECT/CT and conventional MIRGP (group I) or multi-phase SPECT/CT and individualised MIRGP (group II). One hundred of 106 eligible patients were included, and 83 patients underwent complete intervention. Results: A total of 47 patients in group I and 35 patients in group II were analysed. Group II had a shorter operating time (p = 0.003). The in vivo sensitivity and accuracy of radio guidance was 85.1% in group I and 100% in group II (p = 0.046), and 90.4% in group I and 100% in group II (p = 0.021), respectively. We found no difference in the in vivo specificity and ex vivo parameters between groups. Conclusion: Individualised timing increased the in vivo sensitivity and accuracy of radio guidance and reduced operating time, as some parathyroid adenomas rapidly wash out the radionuclide. |
format | Online Article Text |
id | pubmed-8070050 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80700502021-04-26 Individualised Timing of Radio-Guided Parathyroidectomy Using Multi-Phase SPECT/CT Increases In Vivo Sensitivity and Accuracy and Reduces Operating Time: A Randomised Clinical Trial Formánek, Martin Dedek, Vladimír Koláček, Michal Havel, Martin Zeleník, Karol Komínek, Pavel Diagnostics (Basel) Article Background: Minimally invasive parathyroidectomy is the preferred treatment for primary hyperparathyroidism. Despite relatively accurate preoperative information, minimally invasive parathyroidectomy can be challenging, especially in the case of small and ectopic adenomas. Radio guidance aids in both in vivo identification and ex vivo confirmation of adenoma. In vivo accuracy is currently not satisfactory. The present study evaluated whether a beneficial effect (increased sensitivity, specificity, accuracy) is obtained with individualised timing of minimally invasive radio-guided parathyroidectomy (MIRGP) using preoperative multi-phase 99mTc-MIBI single photon emission computed tomography (SPECT)/computed tomography (CT). Methods: This randomised clinical trial was conducted from May 2016 to January 2020 in a tertiary referral hospital. Adult patients with primary hyperparathyroidism sent for 99mTc-MIBI SPECT/CT were included consecutively and randomly assigned to conventional (dual-phase) SPECT/CT and conventional MIRGP (group I) or multi-phase SPECT/CT and individualised MIRGP (group II). One hundred of 106 eligible patients were included, and 83 patients underwent complete intervention. Results: A total of 47 patients in group I and 35 patients in group II were analysed. Group II had a shorter operating time (p = 0.003). The in vivo sensitivity and accuracy of radio guidance was 85.1% in group I and 100% in group II (p = 0.046), and 90.4% in group I and 100% in group II (p = 0.021), respectively. We found no difference in the in vivo specificity and ex vivo parameters between groups. Conclusion: Individualised timing increased the in vivo sensitivity and accuracy of radio guidance and reduced operating time, as some parathyroid adenomas rapidly wash out the radionuclide. MDPI 2021-04-09 /pmc/articles/PMC8070050/ /pubmed/33918800 http://dx.doi.org/10.3390/diagnostics11040677 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Formánek, Martin Dedek, Vladimír Koláček, Michal Havel, Martin Zeleník, Karol Komínek, Pavel Individualised Timing of Radio-Guided Parathyroidectomy Using Multi-Phase SPECT/CT Increases In Vivo Sensitivity and Accuracy and Reduces Operating Time: A Randomised Clinical Trial |
title | Individualised Timing of Radio-Guided Parathyroidectomy Using Multi-Phase SPECT/CT Increases In Vivo Sensitivity and Accuracy and Reduces Operating Time: A Randomised Clinical Trial |
title_full | Individualised Timing of Radio-Guided Parathyroidectomy Using Multi-Phase SPECT/CT Increases In Vivo Sensitivity and Accuracy and Reduces Operating Time: A Randomised Clinical Trial |
title_fullStr | Individualised Timing of Radio-Guided Parathyroidectomy Using Multi-Phase SPECT/CT Increases In Vivo Sensitivity and Accuracy and Reduces Operating Time: A Randomised Clinical Trial |
title_full_unstemmed | Individualised Timing of Radio-Guided Parathyroidectomy Using Multi-Phase SPECT/CT Increases In Vivo Sensitivity and Accuracy and Reduces Operating Time: A Randomised Clinical Trial |
title_short | Individualised Timing of Radio-Guided Parathyroidectomy Using Multi-Phase SPECT/CT Increases In Vivo Sensitivity and Accuracy and Reduces Operating Time: A Randomised Clinical Trial |
title_sort | individualised timing of radio-guided parathyroidectomy using multi-phase spect/ct increases in vivo sensitivity and accuracy and reduces operating time: a randomised clinical trial |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8070050/ https://www.ncbi.nlm.nih.gov/pubmed/33918800 http://dx.doi.org/10.3390/diagnostics11040677 |
work_keys_str_mv | AT formanekmartin individualisedtimingofradioguidedparathyroidectomyusingmultiphasespectctincreasesinvivosensitivityandaccuracyandreducesoperatingtimearandomisedclinicaltrial AT dedekvladimir individualisedtimingofradioguidedparathyroidectomyusingmultiphasespectctincreasesinvivosensitivityandaccuracyandreducesoperatingtimearandomisedclinicaltrial AT kolacekmichal individualisedtimingofradioguidedparathyroidectomyusingmultiphasespectctincreasesinvivosensitivityandaccuracyandreducesoperatingtimearandomisedclinicaltrial AT havelmartin individualisedtimingofradioguidedparathyroidectomyusingmultiphasespectctincreasesinvivosensitivityandaccuracyandreducesoperatingtimearandomisedclinicaltrial AT zelenikkarol individualisedtimingofradioguidedparathyroidectomyusingmultiphasespectctincreasesinvivosensitivityandaccuracyandreducesoperatingtimearandomisedclinicaltrial AT kominekpavel individualisedtimingofradioguidedparathyroidectomyusingmultiphasespectctincreasesinvivosensitivityandaccuracyandreducesoperatingtimearandomisedclinicaltrial |