Preliminary Evaluation of Filtration Efficiency and Differential Pressure ASTM F3502 Testing Methods of Non-Medical Masks Using a Face Filtration Mount

Research surrounding the mandated use of non-medical fabric masks is inconsistent and often confusing when compared to the standard N95. A recently published standard from ASTM International and the Centers for Disease Control and Prevention attempts to normalize evaluation procedures. The purpose o...

Descripción completa

Detalles Bibliográficos
Autores principales: Freeman, Charles, Burch, Reuben, Strawderman, Lesley, Black, Catherine, Saucier, David, Rickert, Jaime, Wilson, John, Bealor, Sarah Ashley, Ratledge, Madison, Fava, Sydney, Smith, Brian, Waggoner, Charlie, Taylor, Courtney, Nichols, Abigail, Skaggs, Gregory, Callans, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8070197/
https://www.ncbi.nlm.nih.gov/pubmed/33924707
http://dx.doi.org/10.3390/ijerph18084124
Descripción
Sumario:Research surrounding the mandated use of non-medical fabric masks is inconsistent and often confusing when compared to the standard N95. A recently published standard from ASTM International and the Centers for Disease Control and Prevention attempts to normalize evaluation procedures. The purpose of this study is to conduct a preliminary evaluation of the new methods for testing filtration efficiency of masks outlined by ASTM International F3502, where results can be directly compared to standards outlined for non-medical fabric masks. Eleven consumer non-medical fabric masks were tested for filtration efficiency and airflow resistance using a face filtration mount in accordance with the newly released ASTM International standard for facial barriers. The mean FE% (SD) ranged from 0.46% (0.44) to 11.80% (2.76) with the 3-layer athletic mesh having the highest performance and the highest deviations. All the masks tested following the procedure failed to meet to minimum FE of 20%; however all masks performed below the minimum upper limits for airflow resistance. Using a non-medical fabric masks as the sole mitigation strategy may not be as effective, as previously reported. With efforts to standardize and regulate the non-medical fabric mask market, this study demonstrates a variety of currently available consumer mask products do not meet the minimum standards nor are these remotely close to the standards of surgical or N95 masks.