Cargando…
Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry
The determination of protease activity is very important for disease diagnosis, drug development, and quality and safety assurance for dairy products. Therefore, the development of low-cost and sensitive methods for assessing protease activity is crucial. We report two approaches for monitoring prot...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8070231/ https://www.ncbi.nlm.nih.gov/pubmed/33920444 http://dx.doi.org/10.3390/bios11040117 |
_version_ | 1783683422153080832 |
---|---|
author | Piovarci, Ivan Melikishvili, Sopio Tatarko, Marek Hianik, Tibor Thompson, Michael |
author_facet | Piovarci, Ivan Melikishvili, Sopio Tatarko, Marek Hianik, Tibor Thompson, Michael |
author_sort | Piovarci, Ivan |
collection | PubMed |
description | The determination of protease activity is very important for disease diagnosis, drug development, and quality and safety assurance for dairy products. Therefore, the development of low-cost and sensitive methods for assessing protease activity is crucial. We report two approaches for monitoring protease activity: in a volume and at surface, via colorimetric and acoustic wave-based biosensors operated in the thickness-shear mode (TSM), respectively. The TSM sensor was based on a β-casein substrate immobilized on a piezoelectric quartz crystal transducer. After an enzymatic reaction with trypsin, it cleaved the surface-bound β-casein, which increased the resonant frequency of the crystal. The limit of detection (LOD) was 0.48 ± 0.08 nM. A label-free colorimetric assay for trypsin detection has also been performed using β-casein and 6-mercaptohexanol (MCH) functionalized gold nanoparticles (AuNPs/MCH-β-casein). Due to the trypsin cleavage of β-casein, the gold nanoparticles lost shelter, and MCH increased the attractive force between the modified AuNPs. Consequently, AuNPs aggregated, and the red shift of the absorption spectra was observed. Spectrophotometric assay enabled an LOD of 0.42 ± 0.03 nM. The Michaelis–Menten constant, K(M), for reverse enzyme reaction has also been estimated by both methods. This value for the colorimetric assay (0.56 ± 0.10 nM) is lower in comparison with those for the TSM sensor (0.92 ± 0.44 nM). This is likely due to the better access of the trypsin to the β-casein substrate at the surface of AuNPs in comparison with those at the TSM transducer. |
format | Online Article Text |
id | pubmed-8070231 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80702312021-04-26 Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry Piovarci, Ivan Melikishvili, Sopio Tatarko, Marek Hianik, Tibor Thompson, Michael Biosensors (Basel) Article The determination of protease activity is very important for disease diagnosis, drug development, and quality and safety assurance for dairy products. Therefore, the development of low-cost and sensitive methods for assessing protease activity is crucial. We report two approaches for monitoring protease activity: in a volume and at surface, via colorimetric and acoustic wave-based biosensors operated in the thickness-shear mode (TSM), respectively. The TSM sensor was based on a β-casein substrate immobilized on a piezoelectric quartz crystal transducer. After an enzymatic reaction with trypsin, it cleaved the surface-bound β-casein, which increased the resonant frequency of the crystal. The limit of detection (LOD) was 0.48 ± 0.08 nM. A label-free colorimetric assay for trypsin detection has also been performed using β-casein and 6-mercaptohexanol (MCH) functionalized gold nanoparticles (AuNPs/MCH-β-casein). Due to the trypsin cleavage of β-casein, the gold nanoparticles lost shelter, and MCH increased the attractive force between the modified AuNPs. Consequently, AuNPs aggregated, and the red shift of the absorption spectra was observed. Spectrophotometric assay enabled an LOD of 0.42 ± 0.03 nM. The Michaelis–Menten constant, K(M), for reverse enzyme reaction has also been estimated by both methods. This value for the colorimetric assay (0.56 ± 0.10 nM) is lower in comparison with those for the TSM sensor (0.92 ± 0.44 nM). This is likely due to the better access of the trypsin to the β-casein substrate at the surface of AuNPs in comparison with those at the TSM transducer. MDPI 2021-04-11 /pmc/articles/PMC8070231/ /pubmed/33920444 http://dx.doi.org/10.3390/bios11040117 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Piovarci, Ivan Melikishvili, Sopio Tatarko, Marek Hianik, Tibor Thompson, Michael Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry |
title | Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry |
title_full | Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry |
title_fullStr | Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry |
title_full_unstemmed | Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry |
title_short | Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry |
title_sort | detection of sub-nanomolar concentration of trypsin by thickness-shear mode acoustic biosensor and spectrophotometry |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8070231/ https://www.ncbi.nlm.nih.gov/pubmed/33920444 http://dx.doi.org/10.3390/bios11040117 |
work_keys_str_mv | AT piovarciivan detectionofsubnanomolarconcentrationoftrypsinbythicknessshearmodeacousticbiosensorandspectrophotometry AT melikishvilisopio detectionofsubnanomolarconcentrationoftrypsinbythicknessshearmodeacousticbiosensorandspectrophotometry AT tatarkomarek detectionofsubnanomolarconcentrationoftrypsinbythicknessshearmodeacousticbiosensorandspectrophotometry AT hianiktibor detectionofsubnanomolarconcentrationoftrypsinbythicknessshearmodeacousticbiosensorandspectrophotometry AT thompsonmichael detectionofsubnanomolarconcentrationoftrypsinbythicknessshearmodeacousticbiosensorandspectrophotometry |