Cargando…

Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry

The determination of protease activity is very important for disease diagnosis, drug development, and quality and safety assurance for dairy products. Therefore, the development of low-cost and sensitive methods for assessing protease activity is crucial. We report two approaches for monitoring prot...

Descripción completa

Detalles Bibliográficos
Autores principales: Piovarci, Ivan, Melikishvili, Sopio, Tatarko, Marek, Hianik, Tibor, Thompson, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8070231/
https://www.ncbi.nlm.nih.gov/pubmed/33920444
http://dx.doi.org/10.3390/bios11040117
_version_ 1783683422153080832
author Piovarci, Ivan
Melikishvili, Sopio
Tatarko, Marek
Hianik, Tibor
Thompson, Michael
author_facet Piovarci, Ivan
Melikishvili, Sopio
Tatarko, Marek
Hianik, Tibor
Thompson, Michael
author_sort Piovarci, Ivan
collection PubMed
description The determination of protease activity is very important for disease diagnosis, drug development, and quality and safety assurance for dairy products. Therefore, the development of low-cost and sensitive methods for assessing protease activity is crucial. We report two approaches for monitoring protease activity: in a volume and at surface, via colorimetric and acoustic wave-based biosensors operated in the thickness-shear mode (TSM), respectively. The TSM sensor was based on a β-casein substrate immobilized on a piezoelectric quartz crystal transducer. After an enzymatic reaction with trypsin, it cleaved the surface-bound β-casein, which increased the resonant frequency of the crystal. The limit of detection (LOD) was 0.48 ± 0.08 nM. A label-free colorimetric assay for trypsin detection has also been performed using β-casein and 6-mercaptohexanol (MCH) functionalized gold nanoparticles (AuNPs/MCH-β-casein). Due to the trypsin cleavage of β-casein, the gold nanoparticles lost shelter, and MCH increased the attractive force between the modified AuNPs. Consequently, AuNPs aggregated, and the red shift of the absorption spectra was observed. Spectrophotometric assay enabled an LOD of 0.42 ± 0.03 nM. The Michaelis–Menten constant, K(M), for reverse enzyme reaction has also been estimated by both methods. This value for the colorimetric assay (0.56 ± 0.10 nM) is lower in comparison with those for the TSM sensor (0.92 ± 0.44 nM). This is likely due to the better access of the trypsin to the β-casein substrate at the surface of AuNPs in comparison with those at the TSM transducer.
format Online
Article
Text
id pubmed-8070231
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80702312021-04-26 Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry Piovarci, Ivan Melikishvili, Sopio Tatarko, Marek Hianik, Tibor Thompson, Michael Biosensors (Basel) Article The determination of protease activity is very important for disease diagnosis, drug development, and quality and safety assurance for dairy products. Therefore, the development of low-cost and sensitive methods for assessing protease activity is crucial. We report two approaches for monitoring protease activity: in a volume and at surface, via colorimetric and acoustic wave-based biosensors operated in the thickness-shear mode (TSM), respectively. The TSM sensor was based on a β-casein substrate immobilized on a piezoelectric quartz crystal transducer. After an enzymatic reaction with trypsin, it cleaved the surface-bound β-casein, which increased the resonant frequency of the crystal. The limit of detection (LOD) was 0.48 ± 0.08 nM. A label-free colorimetric assay for trypsin detection has also been performed using β-casein and 6-mercaptohexanol (MCH) functionalized gold nanoparticles (AuNPs/MCH-β-casein). Due to the trypsin cleavage of β-casein, the gold nanoparticles lost shelter, and MCH increased the attractive force between the modified AuNPs. Consequently, AuNPs aggregated, and the red shift of the absorption spectra was observed. Spectrophotometric assay enabled an LOD of 0.42 ± 0.03 nM. The Michaelis–Menten constant, K(M), for reverse enzyme reaction has also been estimated by both methods. This value for the colorimetric assay (0.56 ± 0.10 nM) is lower in comparison with those for the TSM sensor (0.92 ± 0.44 nM). This is likely due to the better access of the trypsin to the β-casein substrate at the surface of AuNPs in comparison with those at the TSM transducer. MDPI 2021-04-11 /pmc/articles/PMC8070231/ /pubmed/33920444 http://dx.doi.org/10.3390/bios11040117 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Piovarci, Ivan
Melikishvili, Sopio
Tatarko, Marek
Hianik, Tibor
Thompson, Michael
Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry
title Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry
title_full Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry
title_fullStr Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry
title_full_unstemmed Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry
title_short Detection of Sub-Nanomolar Concentration of Trypsin by Thickness-Shear Mode Acoustic Biosensor and Spectrophotometry
title_sort detection of sub-nanomolar concentration of trypsin by thickness-shear mode acoustic biosensor and spectrophotometry
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8070231/
https://www.ncbi.nlm.nih.gov/pubmed/33920444
http://dx.doi.org/10.3390/bios11040117
work_keys_str_mv AT piovarciivan detectionofsubnanomolarconcentrationoftrypsinbythicknessshearmodeacousticbiosensorandspectrophotometry
AT melikishvilisopio detectionofsubnanomolarconcentrationoftrypsinbythicknessshearmodeacousticbiosensorandspectrophotometry
AT tatarkomarek detectionofsubnanomolarconcentrationoftrypsinbythicknessshearmodeacousticbiosensorandspectrophotometry
AT hianiktibor detectionofsubnanomolarconcentrationoftrypsinbythicknessshearmodeacousticbiosensorandspectrophotometry
AT thompsonmichael detectionofsubnanomolarconcentrationoftrypsinbythicknessshearmodeacousticbiosensorandspectrophotometry