Cargando…

Effects of Groove Sealing of the Posterior Occlusal Surface and Offset of the Internal Surface on the Internal Fit and Accuracy of Implant Placements Using 3D-Printed Surgical Guides: An In Vitro Study

This study evaluated the internal fit and the accuracy of the implant placement position in order to determine how the surface shape of the tooth and the offset influence the accuracy of the surgical guide. The acquired digital data were analyzed in three dimensions using 3D inspection software. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Lim, Jung-Hwa, Bayarsaikhan, Enkhjargal, Shin, Seung-Ho, Nam, Na-Eun, Shim, June-Sung, Kim, Jong-Eun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8070577/
https://www.ncbi.nlm.nih.gov/pubmed/33920389
http://dx.doi.org/10.3390/polym13081236
_version_ 1783683502664843264
author Lim, Jung-Hwa
Bayarsaikhan, Enkhjargal
Shin, Seung-Ho
Nam, Na-Eun
Shim, June-Sung
Kim, Jong-Eun
author_facet Lim, Jung-Hwa
Bayarsaikhan, Enkhjargal
Shin, Seung-Ho
Nam, Na-Eun
Shim, June-Sung
Kim, Jong-Eun
author_sort Lim, Jung-Hwa
collection PubMed
description This study evaluated the internal fit and the accuracy of the implant placement position in order to determine how the surface shape of the tooth and the offset influence the accuracy of the surgical guide. The acquired digital data were analyzed in three dimensions using 3D inspection software. The obtained results confirmed that the internal fit was better in the groove sealing (GS) group (164.45 ± 28.34 μm) than the original shape (OS) group (204.07 ± 44.60 μm) (p < 0.001), and for an offset of 100 μm (157.50 ± 17.26 μm) than for offsets of 30 μm (206.48 ± 39.12 μm) and 60 μm (188.82 ± 48.77 μm) (p < 0.001). The accuracy of implant placement was better in the GS than OS group in terms of the entry (OS, 0.229 ± 0.092 mm; GS, 0.169 ± 0.061 mm; p < 0.001), apex (OS, 0.324 ± 0.149 mm; GS, 0.230 ± 0.124 mm; p < 0.001), and depth (OS, 0.041 ± 0.027 mm; GS, 0.025 ± 0.022 mm; p < 0.001). In addition, the entries (30 μm, 0.215 ± 0.044 mm; 60 μm, 0.172 ± 0.049 mm; 100 μm, 0.119 ± 0.050 mm; p < 0.001) were only affected by the amount of offset. These findings indicate that the accuracy of a surgical guide can be improved by directly sealing the groove of the tooth before manufacturing the surgical guide or setting the offset during the design process.
format Online
Article
Text
id pubmed-8070577
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80705772021-04-26 Effects of Groove Sealing of the Posterior Occlusal Surface and Offset of the Internal Surface on the Internal Fit and Accuracy of Implant Placements Using 3D-Printed Surgical Guides: An In Vitro Study Lim, Jung-Hwa Bayarsaikhan, Enkhjargal Shin, Seung-Ho Nam, Na-Eun Shim, June-Sung Kim, Jong-Eun Polymers (Basel) Article This study evaluated the internal fit and the accuracy of the implant placement position in order to determine how the surface shape of the tooth and the offset influence the accuracy of the surgical guide. The acquired digital data were analyzed in three dimensions using 3D inspection software. The obtained results confirmed that the internal fit was better in the groove sealing (GS) group (164.45 ± 28.34 μm) than the original shape (OS) group (204.07 ± 44.60 μm) (p < 0.001), and for an offset of 100 μm (157.50 ± 17.26 μm) than for offsets of 30 μm (206.48 ± 39.12 μm) and 60 μm (188.82 ± 48.77 μm) (p < 0.001). The accuracy of implant placement was better in the GS than OS group in terms of the entry (OS, 0.229 ± 0.092 mm; GS, 0.169 ± 0.061 mm; p < 0.001), apex (OS, 0.324 ± 0.149 mm; GS, 0.230 ± 0.124 mm; p < 0.001), and depth (OS, 0.041 ± 0.027 mm; GS, 0.025 ± 0.022 mm; p < 0.001). In addition, the entries (30 μm, 0.215 ± 0.044 mm; 60 μm, 0.172 ± 0.049 mm; 100 μm, 0.119 ± 0.050 mm; p < 0.001) were only affected by the amount of offset. These findings indicate that the accuracy of a surgical guide can be improved by directly sealing the groove of the tooth before manufacturing the surgical guide or setting the offset during the design process. MDPI 2021-04-11 /pmc/articles/PMC8070577/ /pubmed/33920389 http://dx.doi.org/10.3390/polym13081236 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lim, Jung-Hwa
Bayarsaikhan, Enkhjargal
Shin, Seung-Ho
Nam, Na-Eun
Shim, June-Sung
Kim, Jong-Eun
Effects of Groove Sealing of the Posterior Occlusal Surface and Offset of the Internal Surface on the Internal Fit and Accuracy of Implant Placements Using 3D-Printed Surgical Guides: An In Vitro Study
title Effects of Groove Sealing of the Posterior Occlusal Surface and Offset of the Internal Surface on the Internal Fit and Accuracy of Implant Placements Using 3D-Printed Surgical Guides: An In Vitro Study
title_full Effects of Groove Sealing of the Posterior Occlusal Surface and Offset of the Internal Surface on the Internal Fit and Accuracy of Implant Placements Using 3D-Printed Surgical Guides: An In Vitro Study
title_fullStr Effects of Groove Sealing of the Posterior Occlusal Surface and Offset of the Internal Surface on the Internal Fit and Accuracy of Implant Placements Using 3D-Printed Surgical Guides: An In Vitro Study
title_full_unstemmed Effects of Groove Sealing of the Posterior Occlusal Surface and Offset of the Internal Surface on the Internal Fit and Accuracy of Implant Placements Using 3D-Printed Surgical Guides: An In Vitro Study
title_short Effects of Groove Sealing of the Posterior Occlusal Surface and Offset of the Internal Surface on the Internal Fit and Accuracy of Implant Placements Using 3D-Printed Surgical Guides: An In Vitro Study
title_sort effects of groove sealing of the posterior occlusal surface and offset of the internal surface on the internal fit and accuracy of implant placements using 3d-printed surgical guides: an in vitro study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8070577/
https://www.ncbi.nlm.nih.gov/pubmed/33920389
http://dx.doi.org/10.3390/polym13081236
work_keys_str_mv AT limjunghwa effectsofgroovesealingoftheposteriorocclusalsurfaceandoffsetoftheinternalsurfaceontheinternalfitandaccuracyofimplantplacementsusing3dprintedsurgicalguidesaninvitrostudy
AT bayarsaikhanenkhjargal effectsofgroovesealingoftheposteriorocclusalsurfaceandoffsetoftheinternalsurfaceontheinternalfitandaccuracyofimplantplacementsusing3dprintedsurgicalguidesaninvitrostudy
AT shinseungho effectsofgroovesealingoftheposteriorocclusalsurfaceandoffsetoftheinternalsurfaceontheinternalfitandaccuracyofimplantplacementsusing3dprintedsurgicalguidesaninvitrostudy
AT namnaeun effectsofgroovesealingoftheposteriorocclusalsurfaceandoffsetoftheinternalsurfaceontheinternalfitandaccuracyofimplantplacementsusing3dprintedsurgicalguidesaninvitrostudy
AT shimjunesung effectsofgroovesealingoftheposteriorocclusalsurfaceandoffsetoftheinternalsurfaceontheinternalfitandaccuracyofimplantplacementsusing3dprintedsurgicalguidesaninvitrostudy
AT kimjongeun effectsofgroovesealingoftheposteriorocclusalsurfaceandoffsetoftheinternalsurfaceontheinternalfitandaccuracyofimplantplacementsusing3dprintedsurgicalguidesaninvitrostudy