Cargando…

Non-Contact Monitoring of Human Vital Signs Using FMCW Millimeter Wave Radar in the 120 GHz Band

A non-contact heartbeat/respiratory rate monitoring system was designed using narrow beam millimeter wave radar. Equipped with a special low sidelobe and small-sized antenna lens at the front end of the receiving and transmitting antennas in the 120 GHz band of frequency-modulated continuous-wave (F...

Descripción completa

Detalles Bibliográficos
Autores principales: Lv, Wenjie, He, Wangdong, Lin, Xipeng, Miao, Jungang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8070581/
https://www.ncbi.nlm.nih.gov/pubmed/33924439
http://dx.doi.org/10.3390/s21082732
_version_ 1783683503597027328
author Lv, Wenjie
He, Wangdong
Lin, Xipeng
Miao, Jungang
author_facet Lv, Wenjie
He, Wangdong
Lin, Xipeng
Miao, Jungang
author_sort Lv, Wenjie
collection PubMed
description A non-contact heartbeat/respiratory rate monitoring system was designed using narrow beam millimeter wave radar. Equipped with a special low sidelobe and small-sized antenna lens at the front end of the receiving and transmitting antennas in the 120 GHz band of frequency-modulated continuous-wave (FMCW) system, this sensor system realizes the narrow beam control of radar, reduces the interference caused by the reflection of other objects in the measurement background, improves the signal-to-clutter ratio (SCR) of the intermediate frequency signal (IF), and reduces the complexity of the subsequent signal processing. In order to solve the problem that the accuracy of heart rate is easy to be interfered with by respiratory harmonics, an adaptive notch filter was applied to filter respiratory harmonics. Meanwhile, the heart rate obtained by fast Fourier transform (FFT) was modified by using the ratio of adjacent elements, which helped to improve the accuracy of heart rate detection. The experimental results show that when the monitoring system is 1 m away from the human body, the probability of respiratory rate detection error within ±2 times for eight volunteers can reach 90.48%, and the detection accuracy of the heart rate can reach 90.54%. Finally, short-term heart rate measurement was realized by means of improved empirical mode decomposition and fast independent component analysis algorithm.
format Online
Article
Text
id pubmed-8070581
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80705812021-04-26 Non-Contact Monitoring of Human Vital Signs Using FMCW Millimeter Wave Radar in the 120 GHz Band Lv, Wenjie He, Wangdong Lin, Xipeng Miao, Jungang Sensors (Basel) Article A non-contact heartbeat/respiratory rate monitoring system was designed using narrow beam millimeter wave radar. Equipped with a special low sidelobe and small-sized antenna lens at the front end of the receiving and transmitting antennas in the 120 GHz band of frequency-modulated continuous-wave (FMCW) system, this sensor system realizes the narrow beam control of radar, reduces the interference caused by the reflection of other objects in the measurement background, improves the signal-to-clutter ratio (SCR) of the intermediate frequency signal (IF), and reduces the complexity of the subsequent signal processing. In order to solve the problem that the accuracy of heart rate is easy to be interfered with by respiratory harmonics, an adaptive notch filter was applied to filter respiratory harmonics. Meanwhile, the heart rate obtained by fast Fourier transform (FFT) was modified by using the ratio of adjacent elements, which helped to improve the accuracy of heart rate detection. The experimental results show that when the monitoring system is 1 m away from the human body, the probability of respiratory rate detection error within ±2 times for eight volunteers can reach 90.48%, and the detection accuracy of the heart rate can reach 90.54%. Finally, short-term heart rate measurement was realized by means of improved empirical mode decomposition and fast independent component analysis algorithm. MDPI 2021-04-13 /pmc/articles/PMC8070581/ /pubmed/33924439 http://dx.doi.org/10.3390/s21082732 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lv, Wenjie
He, Wangdong
Lin, Xipeng
Miao, Jungang
Non-Contact Monitoring of Human Vital Signs Using FMCW Millimeter Wave Radar in the 120 GHz Band
title Non-Contact Monitoring of Human Vital Signs Using FMCW Millimeter Wave Radar in the 120 GHz Band
title_full Non-Contact Monitoring of Human Vital Signs Using FMCW Millimeter Wave Radar in the 120 GHz Band
title_fullStr Non-Contact Monitoring of Human Vital Signs Using FMCW Millimeter Wave Radar in the 120 GHz Band
title_full_unstemmed Non-Contact Monitoring of Human Vital Signs Using FMCW Millimeter Wave Radar in the 120 GHz Band
title_short Non-Contact Monitoring of Human Vital Signs Using FMCW Millimeter Wave Radar in the 120 GHz Band
title_sort non-contact monitoring of human vital signs using fmcw millimeter wave radar in the 120 ghz band
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8070581/
https://www.ncbi.nlm.nih.gov/pubmed/33924439
http://dx.doi.org/10.3390/s21082732
work_keys_str_mv AT lvwenjie noncontactmonitoringofhumanvitalsignsusingfmcwmillimeterwaveradarinthe120ghzband
AT hewangdong noncontactmonitoringofhumanvitalsignsusingfmcwmillimeterwaveradarinthe120ghzband
AT linxipeng noncontactmonitoringofhumanvitalsignsusingfmcwmillimeterwaveradarinthe120ghzband
AT miaojungang noncontactmonitoringofhumanvitalsignsusingfmcwmillimeterwaveradarinthe120ghzband