Cargando…

Biomechanical Comparison of an All-Inside Meniscal Repair Device Construct Versus Pullout Sutures for Arthroscopic Transtibial Repair of Posterior Medial Meniscus Root Tears: A Matched-Pair Cadaveric Study

BACKGROUND: Meniscus root repairs are important for restoring knee function after a complete meniscus root tear. Various suturing patterns have been proposed for the root repair. The 2-simple-stitches (TSS) method is currently the preferred technique, as it is simplest to perform and allows the leas...

Descripción completa

Detalles Bibliográficos
Autores principales: Vertullo, Christopher J., Cadman, Joseph, Dabirrahmani, Danè, Appleyard, Richard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8072104/
https://www.ncbi.nlm.nih.gov/pubmed/33997064
http://dx.doi.org/10.1177/23259671211000464
_version_ 1783683852070289408
author Vertullo, Christopher J.
Cadman, Joseph
Dabirrahmani, Danè
Appleyard, Richard
author_facet Vertullo, Christopher J.
Cadman, Joseph
Dabirrahmani, Danè
Appleyard, Richard
author_sort Vertullo, Christopher J.
collection PubMed
description BACKGROUND: Meniscus root repairs are important for restoring knee function after a complete meniscus root tear. Various suturing patterns have been proposed for the root repair. The 2-simple-stitches (TSS) method is currently the preferred technique, as it is simplest to perform and allows the least displacement of the meniscus root. PURPOSE: To compare the biomechanical properties of a posterior medial meniscus transtibial root repair consisting of an all-inside meniscal repair device (AMRD) construct with the TSS pullout suture pattern. STUDY DESIGN: Controlled laboratory study. METHODS: Ten pairs of cadaveric medial menisci were prepared with 1 of the 2 constructs. The constructs were randomized between pairs. All constructs were subjected to preloading with 2 N for 10 seconds and then cyclic loading from 5 N to 20 N for 1000 cycles at a frequency of 0.5 Hz. Subsequently, the menisci were loaded to failure at a rate of 0.5 mm/s. All loads were applied in-line with the circumferential meniscal fibers near the posterior medial meniscal horn. RESULTS: The mean yield load and stiffness were similar for both constructs. The elongation after cyclic loading was greater for the AMRD. The displacement at both yield load and ultimate failure were also higher for the AMRD. The ultimate failure load of the AMRD was also significantly higher. During load to failure, the mode of failure in the AMRD was heterogeneous. All the TSS constructs failed by suture cutout. CONCLUSION: Posterior medial meniscus root repairs using both the AMRD and TSS constructs have elongation under the biomechanically acceptable threshold of 3 mm. The stiffness and yield loads indicate similar mechanical properties of the constructs. However, the significantly higher elongation for the AMRD leaves the TSS method as the preferred option for transtibial repairs. Despite this, the AMRD construct may still represent a viable alternative to the TSS suture pattern, comparable to alternative suture patterns with similar limitations. CLINICAL RELEVANCE: The AMRD construct may represent a viable alternative to the TSS suture pattern.
format Online
Article
Text
id pubmed-8072104
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-80721042021-05-13 Biomechanical Comparison of an All-Inside Meniscal Repair Device Construct Versus Pullout Sutures for Arthroscopic Transtibial Repair of Posterior Medial Meniscus Root Tears: A Matched-Pair Cadaveric Study Vertullo, Christopher J. Cadman, Joseph Dabirrahmani, Danè Appleyard, Richard Orthop J Sports Med Article BACKGROUND: Meniscus root repairs are important for restoring knee function after a complete meniscus root tear. Various suturing patterns have been proposed for the root repair. The 2-simple-stitches (TSS) method is currently the preferred technique, as it is simplest to perform and allows the least displacement of the meniscus root. PURPOSE: To compare the biomechanical properties of a posterior medial meniscus transtibial root repair consisting of an all-inside meniscal repair device (AMRD) construct with the TSS pullout suture pattern. STUDY DESIGN: Controlled laboratory study. METHODS: Ten pairs of cadaveric medial menisci were prepared with 1 of the 2 constructs. The constructs were randomized between pairs. All constructs were subjected to preloading with 2 N for 10 seconds and then cyclic loading from 5 N to 20 N for 1000 cycles at a frequency of 0.5 Hz. Subsequently, the menisci were loaded to failure at a rate of 0.5 mm/s. All loads were applied in-line with the circumferential meniscal fibers near the posterior medial meniscal horn. RESULTS: The mean yield load and stiffness were similar for both constructs. The elongation after cyclic loading was greater for the AMRD. The displacement at both yield load and ultimate failure were also higher for the AMRD. The ultimate failure load of the AMRD was also significantly higher. During load to failure, the mode of failure in the AMRD was heterogeneous. All the TSS constructs failed by suture cutout. CONCLUSION: Posterior medial meniscus root repairs using both the AMRD and TSS constructs have elongation under the biomechanically acceptable threshold of 3 mm. The stiffness and yield loads indicate similar mechanical properties of the constructs. However, the significantly higher elongation for the AMRD leaves the TSS method as the preferred option for transtibial repairs. Despite this, the AMRD construct may still represent a viable alternative to the TSS suture pattern, comparable to alternative suture patterns with similar limitations. CLINICAL RELEVANCE: The AMRD construct may represent a viable alternative to the TSS suture pattern. SAGE Publications 2021-04-22 /pmc/articles/PMC8072104/ /pubmed/33997064 http://dx.doi.org/10.1177/23259671211000464 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Vertullo, Christopher J.
Cadman, Joseph
Dabirrahmani, Danè
Appleyard, Richard
Biomechanical Comparison of an All-Inside Meniscal Repair Device Construct Versus Pullout Sutures for Arthroscopic Transtibial Repair of Posterior Medial Meniscus Root Tears: A Matched-Pair Cadaveric Study
title Biomechanical Comparison of an All-Inside Meniscal Repair Device Construct Versus Pullout Sutures for Arthroscopic Transtibial Repair of Posterior Medial Meniscus Root Tears: A Matched-Pair Cadaveric Study
title_full Biomechanical Comparison of an All-Inside Meniscal Repair Device Construct Versus Pullout Sutures for Arthroscopic Transtibial Repair of Posterior Medial Meniscus Root Tears: A Matched-Pair Cadaveric Study
title_fullStr Biomechanical Comparison of an All-Inside Meniscal Repair Device Construct Versus Pullout Sutures for Arthroscopic Transtibial Repair of Posterior Medial Meniscus Root Tears: A Matched-Pair Cadaveric Study
title_full_unstemmed Biomechanical Comparison of an All-Inside Meniscal Repair Device Construct Versus Pullout Sutures for Arthroscopic Transtibial Repair of Posterior Medial Meniscus Root Tears: A Matched-Pair Cadaveric Study
title_short Biomechanical Comparison of an All-Inside Meniscal Repair Device Construct Versus Pullout Sutures for Arthroscopic Transtibial Repair of Posterior Medial Meniscus Root Tears: A Matched-Pair Cadaveric Study
title_sort biomechanical comparison of an all-inside meniscal repair device construct versus pullout sutures for arthroscopic transtibial repair of posterior medial meniscus root tears: a matched-pair cadaveric study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8072104/
https://www.ncbi.nlm.nih.gov/pubmed/33997064
http://dx.doi.org/10.1177/23259671211000464
work_keys_str_mv AT vertullochristopherj biomechanicalcomparisonofanallinsidemeniscalrepairdeviceconstructversuspulloutsuturesforarthroscopictranstibialrepairofposteriormedialmeniscusroottearsamatchedpaircadavericstudy
AT cadmanjoseph biomechanicalcomparisonofanallinsidemeniscalrepairdeviceconstructversuspulloutsuturesforarthroscopictranstibialrepairofposteriormedialmeniscusroottearsamatchedpaircadavericstudy
AT dabirrahmanidane biomechanicalcomparisonofanallinsidemeniscalrepairdeviceconstructversuspulloutsuturesforarthroscopictranstibialrepairofposteriormedialmeniscusroottearsamatchedpaircadavericstudy
AT appleyardrichard biomechanicalcomparisonofanallinsidemeniscalrepairdeviceconstructversuspulloutsuturesforarthroscopictranstibialrepairofposteriormedialmeniscusroottearsamatchedpaircadavericstudy