Cargando…

Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids—Efficiency Assessment with the Use of Dynamic Contrast-Enhanced Magnetic Resonance Imaging and the Potential Role of the Administration of Uterotonic Drugs

Objective: The assessment of the usefulness of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) when qualifying patients with uterine fibroids (UFs) for magnetic resonance-guided high-intensity ultrasound (MR-HIFU). Material and methods: This retrospective, single center study included...

Descripción completa

Detalles Bibliográficos
Autores principales: Łoziński, Tomasz, Ciebiera, Michał, Łuczyńska, Elżbieta, Filipowska, Justyna, Czekierdowski, Artur
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8072686/
https://www.ncbi.nlm.nih.gov/pubmed/33923667
http://dx.doi.org/10.3390/diagnostics11040715
_version_ 1783683964270018560
author Łoziński, Tomasz
Ciebiera, Michał
Łuczyńska, Elżbieta
Filipowska, Justyna
Czekierdowski, Artur
author_facet Łoziński, Tomasz
Ciebiera, Michał
Łuczyńska, Elżbieta
Filipowska, Justyna
Czekierdowski, Artur
author_sort Łoziński, Tomasz
collection PubMed
description Objective: The assessment of the usefulness of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) when qualifying patients with uterine fibroids (UFs) for magnetic resonance-guided high-intensity ultrasound (MR-HIFU). Material and methods: This retrospective, single center study included 283 women who underwent DCE-MRI and were treated with MR-HIFU. The patients were divided according to non-perfused volume (NPV) as well as by the type of curve for patients with a washout curve in the DCE-MRI study and patients without a washout curve. The studied women were assessed in three groups according to the type of uterotonics administered. Group A (57 patients) received one dose of misoprostol/diclofenac transvaginally and group B (71 patients) received oxytocin intravenously prior to the MR-HIFU procedure. The remaining 155 women (group C) were treated with the traditional non-drug enhanced MR-HIFU procedure. Results: The average NPV value was higher in no washout group, and depended on the uterotonics used. Conclusions: We demonstrated a correlation between dynamic contrast enhancement curve types and the therapeutic efficacy of MR-HIFU. Our results suggest that DCE-MRI has the potential to assess treatment outcomes among patients with UFs, and patients with UFs that present with a washout curve may benefit from the use of uterotonic drugs. More studies are required to draw final conclusions.
format Online
Article
Text
id pubmed-8072686
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80726862021-04-27 Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids—Efficiency Assessment with the Use of Dynamic Contrast-Enhanced Magnetic Resonance Imaging and the Potential Role of the Administration of Uterotonic Drugs Łoziński, Tomasz Ciebiera, Michał Łuczyńska, Elżbieta Filipowska, Justyna Czekierdowski, Artur Diagnostics (Basel) Article Objective: The assessment of the usefulness of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) when qualifying patients with uterine fibroids (UFs) for magnetic resonance-guided high-intensity ultrasound (MR-HIFU). Material and methods: This retrospective, single center study included 283 women who underwent DCE-MRI and were treated with MR-HIFU. The patients were divided according to non-perfused volume (NPV) as well as by the type of curve for patients with a washout curve in the DCE-MRI study and patients without a washout curve. The studied women were assessed in three groups according to the type of uterotonics administered. Group A (57 patients) received one dose of misoprostol/diclofenac transvaginally and group B (71 patients) received oxytocin intravenously prior to the MR-HIFU procedure. The remaining 155 women (group C) were treated with the traditional non-drug enhanced MR-HIFU procedure. Results: The average NPV value was higher in no washout group, and depended on the uterotonics used. Conclusions: We demonstrated a correlation between dynamic contrast enhancement curve types and the therapeutic efficacy of MR-HIFU. Our results suggest that DCE-MRI has the potential to assess treatment outcomes among patients with UFs, and patients with UFs that present with a washout curve may benefit from the use of uterotonic drugs. More studies are required to draw final conclusions. MDPI 2021-04-16 /pmc/articles/PMC8072686/ /pubmed/33923667 http://dx.doi.org/10.3390/diagnostics11040715 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Łoziński, Tomasz
Ciebiera, Michał
Łuczyńska, Elżbieta
Filipowska, Justyna
Czekierdowski, Artur
Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids—Efficiency Assessment with the Use of Dynamic Contrast-Enhanced Magnetic Resonance Imaging and the Potential Role of the Administration of Uterotonic Drugs
title Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids—Efficiency Assessment with the Use of Dynamic Contrast-Enhanced Magnetic Resonance Imaging and the Potential Role of the Administration of Uterotonic Drugs
title_full Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids—Efficiency Assessment with the Use of Dynamic Contrast-Enhanced Magnetic Resonance Imaging and the Potential Role of the Administration of Uterotonic Drugs
title_fullStr Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids—Efficiency Assessment with the Use of Dynamic Contrast-Enhanced Magnetic Resonance Imaging and the Potential Role of the Administration of Uterotonic Drugs
title_full_unstemmed Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids—Efficiency Assessment with the Use of Dynamic Contrast-Enhanced Magnetic Resonance Imaging and the Potential Role of the Administration of Uterotonic Drugs
title_short Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids—Efficiency Assessment with the Use of Dynamic Contrast-Enhanced Magnetic Resonance Imaging and the Potential Role of the Administration of Uterotonic Drugs
title_sort magnetic resonance-guided high-intensity focused ultrasound ablation of uterine fibroids—efficiency assessment with the use of dynamic contrast-enhanced magnetic resonance imaging and the potential role of the administration of uterotonic drugs
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8072686/
https://www.ncbi.nlm.nih.gov/pubmed/33923667
http://dx.doi.org/10.3390/diagnostics11040715
work_keys_str_mv AT łozinskitomasz magneticresonanceguidedhighintensityfocusedultrasoundablationofuterinefibroidsefficiencyassessmentwiththeuseofdynamiccontrastenhancedmagneticresonanceimagingandthepotentialroleoftheadministrationofuterotonicdrugs
AT ciebieramichał magneticresonanceguidedhighintensityfocusedultrasoundablationofuterinefibroidsefficiencyassessmentwiththeuseofdynamiccontrastenhancedmagneticresonanceimagingandthepotentialroleoftheadministrationofuterotonicdrugs
AT łuczynskaelzbieta magneticresonanceguidedhighintensityfocusedultrasoundablationofuterinefibroidsefficiencyassessmentwiththeuseofdynamiccontrastenhancedmagneticresonanceimagingandthepotentialroleoftheadministrationofuterotonicdrugs
AT filipowskajustyna magneticresonanceguidedhighintensityfocusedultrasoundablationofuterinefibroidsefficiencyassessmentwiththeuseofdynamiccontrastenhancedmagneticresonanceimagingandthepotentialroleoftheadministrationofuterotonicdrugs
AT czekierdowskiartur magneticresonanceguidedhighintensityfocusedultrasoundablationofuterinefibroidsefficiencyassessmentwiththeuseofdynamiccontrastenhancedmagneticresonanceimagingandthepotentialroleoftheadministrationofuterotonicdrugs