Cargando…
Does Head Orientation Influence 3D Facial Imaging? A Study on Accuracy and Precision of Stereophotogrammetric Acquisition
This study investigates the reliability and precision of anthropometric measurements collected from 3D images and acquired under different conditions of head rotation. Various sources of error were examined, and the equivalence between craniofacial data generated from alternative head positions was...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8073202/ https://www.ncbi.nlm.nih.gov/pubmed/33920674 http://dx.doi.org/10.3390/ijerph18084276 |
_version_ | 1783684078916075520 |
---|---|
author | Battistoni, Giuditta Cassi, Diana Magnifico, Marisabel Pedrazzi, Giuseppe Di Blasio, Marco Vaienti, Benedetta Di Blasio, Alberto |
author_facet | Battistoni, Giuditta Cassi, Diana Magnifico, Marisabel Pedrazzi, Giuseppe Di Blasio, Marco Vaienti, Benedetta Di Blasio, Alberto |
author_sort | Battistoni, Giuditta |
collection | PubMed |
description | This study investigates the reliability and precision of anthropometric measurements collected from 3D images and acquired under different conditions of head rotation. Various sources of error were examined, and the equivalence between craniofacial data generated from alternative head positions was assessed. 3D captures of a mannequin head were obtained with a stereophotogrammetric system (Face Shape 3D MaxiLine). Image acquisition was performed with no rotations and with various pitch, roll, and yaw angulations. On 3D images, 14 linear distances were measured. Various indices were used to quantify error magnitude, among them the acquisition error, the mean and the maximum intra- and inter-operator measurement error, repeatability and reproducibility error, the standard deviation, and the standard error of errors. Two one-sided tests (TOST) were performed to assess the equivalence between measurements recorded in different head angulations. The maximum intra-operator error was very low (0.336 mm), closely followed by the acquisition error (0.496 mm). The maximum inter-operator error was 0.532 mm, and the highest degree of error was found in reproducibility (0.890 mm). Anthropometric measurements from alternative acquisition conditions resulted in significantly equivalent TOST, with the exception of Zygion (l)–Tragion (l) and Cheek (l)–Tragion (l) distances measured with pitch angulation compared to no rotation position. Face Shape 3D Maxiline has sufficient accuracy for orthodontic and surgical use. Precision was not altered by head orientation, making the acquisition simpler and not constrained to a critical precision as in 2D photographs. |
format | Online Article Text |
id | pubmed-8073202 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80732022021-04-27 Does Head Orientation Influence 3D Facial Imaging? A Study on Accuracy and Precision of Stereophotogrammetric Acquisition Battistoni, Giuditta Cassi, Diana Magnifico, Marisabel Pedrazzi, Giuseppe Di Blasio, Marco Vaienti, Benedetta Di Blasio, Alberto Int J Environ Res Public Health Article This study investigates the reliability and precision of anthropometric measurements collected from 3D images and acquired under different conditions of head rotation. Various sources of error were examined, and the equivalence between craniofacial data generated from alternative head positions was assessed. 3D captures of a mannequin head were obtained with a stereophotogrammetric system (Face Shape 3D MaxiLine). Image acquisition was performed with no rotations and with various pitch, roll, and yaw angulations. On 3D images, 14 linear distances were measured. Various indices were used to quantify error magnitude, among them the acquisition error, the mean and the maximum intra- and inter-operator measurement error, repeatability and reproducibility error, the standard deviation, and the standard error of errors. Two one-sided tests (TOST) were performed to assess the equivalence between measurements recorded in different head angulations. The maximum intra-operator error was very low (0.336 mm), closely followed by the acquisition error (0.496 mm). The maximum inter-operator error was 0.532 mm, and the highest degree of error was found in reproducibility (0.890 mm). Anthropometric measurements from alternative acquisition conditions resulted in significantly equivalent TOST, with the exception of Zygion (l)–Tragion (l) and Cheek (l)–Tragion (l) distances measured with pitch angulation compared to no rotation position. Face Shape 3D Maxiline has sufficient accuracy for orthodontic and surgical use. Precision was not altered by head orientation, making the acquisition simpler and not constrained to a critical precision as in 2D photographs. MDPI 2021-04-17 /pmc/articles/PMC8073202/ /pubmed/33920674 http://dx.doi.org/10.3390/ijerph18084276 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Battistoni, Giuditta Cassi, Diana Magnifico, Marisabel Pedrazzi, Giuseppe Di Blasio, Marco Vaienti, Benedetta Di Blasio, Alberto Does Head Orientation Influence 3D Facial Imaging? A Study on Accuracy and Precision of Stereophotogrammetric Acquisition |
title | Does Head Orientation Influence 3D Facial Imaging? A Study on Accuracy and Precision of Stereophotogrammetric Acquisition |
title_full | Does Head Orientation Influence 3D Facial Imaging? A Study on Accuracy and Precision of Stereophotogrammetric Acquisition |
title_fullStr | Does Head Orientation Influence 3D Facial Imaging? A Study on Accuracy and Precision of Stereophotogrammetric Acquisition |
title_full_unstemmed | Does Head Orientation Influence 3D Facial Imaging? A Study on Accuracy and Precision of Stereophotogrammetric Acquisition |
title_short | Does Head Orientation Influence 3D Facial Imaging? A Study on Accuracy and Precision of Stereophotogrammetric Acquisition |
title_sort | does head orientation influence 3d facial imaging? a study on accuracy and precision of stereophotogrammetric acquisition |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8073202/ https://www.ncbi.nlm.nih.gov/pubmed/33920674 http://dx.doi.org/10.3390/ijerph18084276 |
work_keys_str_mv | AT battistonigiuditta doesheadorientationinfluence3dfacialimagingastudyonaccuracyandprecisionofstereophotogrammetricacquisition AT cassidiana doesheadorientationinfluence3dfacialimagingastudyonaccuracyandprecisionofstereophotogrammetricacquisition AT magnificomarisabel doesheadorientationinfluence3dfacialimagingastudyonaccuracyandprecisionofstereophotogrammetricacquisition AT pedrazzigiuseppe doesheadorientationinfluence3dfacialimagingastudyonaccuracyandprecisionofstereophotogrammetricacquisition AT diblasiomarco doesheadorientationinfluence3dfacialimagingastudyonaccuracyandprecisionofstereophotogrammetricacquisition AT vaientibenedetta doesheadorientationinfluence3dfacialimagingastudyonaccuracyandprecisionofstereophotogrammetricacquisition AT diblasioalberto doesheadorientationinfluence3dfacialimagingastudyonaccuracyandprecisionofstereophotogrammetricacquisition |