A comparison of SanatMetal Sanat Swing and Zimmer NexGen® total knee implants: 10-year postoperative follow-up results
OBJECTIVES: In this study, we present our 10-year postoperative follow-up results of Sanat Swing® and NexGen® total knee implants. PATIENTS AND METHODS: A total of 189 patients (93 males, 96 females; mean age: 68 years; range, 48 to 86 years) who underwent total knee replacement between January 2008...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bayçınar Medical Publishing
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8073429/ https://www.ncbi.nlm.nih.gov/pubmed/33463412 http://dx.doi.org/10.5606/ehc.2021.76756 |
_version_ | 1783684128188661760 |
---|---|
author | Abonyi, Bence Pap, Karoly Gal, Tamas Vasarhelyi, Gabor Udvarhelyi, Ivan Hangody, Laszlo |
author_facet | Abonyi, Bence Pap, Karoly Gal, Tamas Vasarhelyi, Gabor Udvarhelyi, Ivan Hangody, Laszlo |
author_sort | Abonyi, Bence |
collection | PubMed |
description | OBJECTIVES: In this study, we present our 10-year postoperative follow-up results of Sanat Swing® and NexGen® total knee implants. PATIENTS AND METHODS: A total of 189 patients (93 males, 96 females; mean age: 68 years; range, 48 to 86 years) who underwent total knee replacement between January 2008 and September 2010 were retrospectively analyzed. A total of 105 patients (Group A) were implanted a cemented Sanat Swing knee prosthesis and 84 patients (Group B) were implanted a cemented NexGen knee prosthesis. Operation time, range of motion (ROM), pain level, Knee Society Score (KSS), distance of painless walking, and the ability to climb stairs were evaluated between the groups. RESULTS: The mean follow-up was 10.8 (range, 9.8 to 12.3) years. No significant difference was observed in the survival of the prostheses, ROM, pain level, KSS, walking distance, and in the ability to climb stairs between the two groups at 10 years. With an experienced team, the operation time was about 4 to 5 min shorter in the Sanat Swing implantation group. In selected cases, Sanat Swing was superior to the NexGen system; however, there was no statistically significant difference. Complication rates were also low and comparable between both groups. CONCLUSION: Based on the 10 years of follow-up evaluation, Sanat Swing total knee replacement system seems to yield comparable clinical results with the NexGen. Experiences with the operative technique and comparative evaluation, the Sanat Swing system is a safe and reliable alternative for total knee replacement, providing a user-friendly operative technique and shorter operation time. |
format | Online Article Text |
id | pubmed-8073429 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Bayçınar Medical Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-80734292021-04-26 A comparison of SanatMetal Sanat Swing and Zimmer NexGen® total knee implants: 10-year postoperative follow-up results Abonyi, Bence Pap, Karoly Gal, Tamas Vasarhelyi, Gabor Udvarhelyi, Ivan Hangody, Laszlo Jt Dis Relat Surg Original Article OBJECTIVES: In this study, we present our 10-year postoperative follow-up results of Sanat Swing® and NexGen® total knee implants. PATIENTS AND METHODS: A total of 189 patients (93 males, 96 females; mean age: 68 years; range, 48 to 86 years) who underwent total knee replacement between January 2008 and September 2010 were retrospectively analyzed. A total of 105 patients (Group A) were implanted a cemented Sanat Swing knee prosthesis and 84 patients (Group B) were implanted a cemented NexGen knee prosthesis. Operation time, range of motion (ROM), pain level, Knee Society Score (KSS), distance of painless walking, and the ability to climb stairs were evaluated between the groups. RESULTS: The mean follow-up was 10.8 (range, 9.8 to 12.3) years. No significant difference was observed in the survival of the prostheses, ROM, pain level, KSS, walking distance, and in the ability to climb stairs between the two groups at 10 years. With an experienced team, the operation time was about 4 to 5 min shorter in the Sanat Swing implantation group. In selected cases, Sanat Swing was superior to the NexGen system; however, there was no statistically significant difference. Complication rates were also low and comparable between both groups. CONCLUSION: Based on the 10 years of follow-up evaluation, Sanat Swing total knee replacement system seems to yield comparable clinical results with the NexGen. Experiences with the operative technique and comparative evaluation, the Sanat Swing system is a safe and reliable alternative for total knee replacement, providing a user-friendly operative technique and shorter operation time. Bayçınar Medical Publishing 2021-01-06 /pmc/articles/PMC8073429/ /pubmed/33463412 http://dx.doi.org/10.5606/ehc.2021.76756 Text en Copyright © 2021, Turkish Joint Diseases Foundation https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Original Article Abonyi, Bence Pap, Karoly Gal, Tamas Vasarhelyi, Gabor Udvarhelyi, Ivan Hangody, Laszlo A comparison of SanatMetal Sanat Swing and Zimmer NexGen® total knee implants: 10-year postoperative follow-up results |
title | A comparison of SanatMetal Sanat Swing and Zimmer NexGen® total knee implants: 10-year postoperative follow-up results |
title_full | A comparison of SanatMetal Sanat Swing and Zimmer NexGen® total knee implants: 10-year postoperative follow-up results |
title_fullStr | A comparison of SanatMetal Sanat Swing and Zimmer NexGen® total knee implants: 10-year postoperative follow-up results |
title_full_unstemmed | A comparison of SanatMetal Sanat Swing and Zimmer NexGen® total knee implants: 10-year postoperative follow-up results |
title_short | A comparison of SanatMetal Sanat Swing and Zimmer NexGen® total knee implants: 10-year postoperative follow-up results |
title_sort | comparison of sanatmetal sanat swing and zimmer nexgen® total knee implants: 10-year postoperative follow-up results |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8073429/ https://www.ncbi.nlm.nih.gov/pubmed/33463412 http://dx.doi.org/10.5606/ehc.2021.76756 |
work_keys_str_mv | AT abonyibence acomparisonofsanatmetalsanatswingandzimmernexgentotalkneeimplants10yearpostoperativefollowupresults AT papkaroly acomparisonofsanatmetalsanatswingandzimmernexgentotalkneeimplants10yearpostoperativefollowupresults AT galtamas acomparisonofsanatmetalsanatswingandzimmernexgentotalkneeimplants10yearpostoperativefollowupresults AT vasarhelyigabor acomparisonofsanatmetalsanatswingandzimmernexgentotalkneeimplants10yearpostoperativefollowupresults AT udvarhelyiivan acomparisonofsanatmetalsanatswingandzimmernexgentotalkneeimplants10yearpostoperativefollowupresults AT hangodylaszlo acomparisonofsanatmetalsanatswingandzimmernexgentotalkneeimplants10yearpostoperativefollowupresults AT abonyibence comparisonofsanatmetalsanatswingandzimmernexgentotalkneeimplants10yearpostoperativefollowupresults AT papkaroly comparisonofsanatmetalsanatswingandzimmernexgentotalkneeimplants10yearpostoperativefollowupresults AT galtamas comparisonofsanatmetalsanatswingandzimmernexgentotalkneeimplants10yearpostoperativefollowupresults AT vasarhelyigabor comparisonofsanatmetalsanatswingandzimmernexgentotalkneeimplants10yearpostoperativefollowupresults AT udvarhelyiivan comparisonofsanatmetalsanatswingandzimmernexgentotalkneeimplants10yearpostoperativefollowupresults AT hangodylaszlo comparisonofsanatmetalsanatswingandzimmernexgentotalkneeimplants10yearpostoperativefollowupresults |