Cargando…
The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis
OBJECTIVES: This study aims to investigate the effects of the angles created by the Kirschner wires (K-wires), which are applied in the percutaneous fixation of supracondylar humerus fractures with cross K-wire, with the fracture line on fracture stabilization. PATIENTS AND METHODS: The study was co...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bayçınar Medical Publishing
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8073442/ https://www.ncbi.nlm.nih.gov/pubmed/33463421 http://dx.doi.org/10.5606/ehc.2021.77279 |
_version_ | 1783684131231629312 |
---|---|
author | Durusoy, Serhat Öner, Kerim Özer, Alaattin Sevinç, Hüseyin Fatih |
author_facet | Durusoy, Serhat Öner, Kerim Özer, Alaattin Sevinç, Hüseyin Fatih |
author_sort | Durusoy, Serhat |
collection | PubMed |
description | OBJECTIVES: This study aims to investigate the effects of the angles created by the Kirschner wires (K-wires), which are applied in the percutaneous fixation of supracondylar humerus fractures with cross K-wire, with the fracture line on fracture stabilization. PATIENTS AND METHODS: The study was conducted on distal humerus fracture models. Medial and lateral K-wires were placed in the fracture models. The angle between the fracture line and the K-wire inserted from medial was represented by alpha (α), while the angle between the fracture line and the K-wires inserted from lateral was represented by beta (β). A combination of various angles (30°, 45°, and 60°) was used in each model, where no two models had the same combination of α and β, resulting in nine different wire configurations. The simulation program was used to simulate the effects of forces, which were applied on rotation, flexion and extension directions, on these models. We measured and compared the stress on the wires and the displacement of fractures under different force configurations. RESULTS: When the force was applied in the counterclockwise direction, the stresses were 58 megaPascal (MPa) on medial K-wire, 24 MPa on lower lateral K-wire, and 45 MPa on upper lateral K-wire in (45°, 45°) wire configuration. When the force was applied in the clockwise direction, the stresses were 57 MPa on medial K-wire, 23 MPa on lower lateral K-wire, and 45 MPa on upper lateral K-wire in (45°, 45°) wire configuration. In all models, the increased α and β angles were translated into the decreased stress on K-wires at the fracture level and decreased displacement under rotational deforming forces. Despite having generally lower fracture displacement, the increased α and β angles led to variable changes in the stress on K-wires against flexion and extension forces. CONCLUSION: In supracondylar humerus fractures, increasing the insertion angle of both medial and lateral K-wires augments stabilization and reduces displacement, particularly against rotational deforming forces. |
format | Online Article Text |
id | pubmed-8073442 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Bayçınar Medical Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-80734422021-04-26 The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis Durusoy, Serhat Öner, Kerim Özer, Alaattin Sevinç, Hüseyin Fatih Jt Dis Relat Surg Original Article OBJECTIVES: This study aims to investigate the effects of the angles created by the Kirschner wires (K-wires), which are applied in the percutaneous fixation of supracondylar humerus fractures with cross K-wire, with the fracture line on fracture stabilization. PATIENTS AND METHODS: The study was conducted on distal humerus fracture models. Medial and lateral K-wires were placed in the fracture models. The angle between the fracture line and the K-wire inserted from medial was represented by alpha (α), while the angle between the fracture line and the K-wires inserted from lateral was represented by beta (β). A combination of various angles (30°, 45°, and 60°) was used in each model, where no two models had the same combination of α and β, resulting in nine different wire configurations. The simulation program was used to simulate the effects of forces, which were applied on rotation, flexion and extension directions, on these models. We measured and compared the stress on the wires and the displacement of fractures under different force configurations. RESULTS: When the force was applied in the counterclockwise direction, the stresses were 58 megaPascal (MPa) on medial K-wire, 24 MPa on lower lateral K-wire, and 45 MPa on upper lateral K-wire in (45°, 45°) wire configuration. When the force was applied in the clockwise direction, the stresses were 57 MPa on medial K-wire, 23 MPa on lower lateral K-wire, and 45 MPa on upper lateral K-wire in (45°, 45°) wire configuration. In all models, the increased α and β angles were translated into the decreased stress on K-wires at the fracture level and decreased displacement under rotational deforming forces. Despite having generally lower fracture displacement, the increased α and β angles led to variable changes in the stress on K-wires against flexion and extension forces. CONCLUSION: In supracondylar humerus fractures, increasing the insertion angle of both medial and lateral K-wires augments stabilization and reduces displacement, particularly against rotational deforming forces. Bayçınar Medical Publishing 2021-01-06 /pmc/articles/PMC8073442/ /pubmed/33463421 http://dx.doi.org/10.5606/ehc.2021.77279 Text en Copyright © 2021, Turkish Joint Diseases Foundation https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Original Article Durusoy, Serhat Öner, Kerim Özer, Alaattin Sevinç, Hüseyin Fatih The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis |
title | The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis |
title_full | The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis |
title_fullStr | The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis |
title_full_unstemmed | The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis |
title_short | The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis |
title_sort | effect of the angle between fracture line and kirschner wires on stability in supracondylar humerus fractures treated with kirschner wire fixation: a finite element analysis |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8073442/ https://www.ncbi.nlm.nih.gov/pubmed/33463421 http://dx.doi.org/10.5606/ehc.2021.77279 |
work_keys_str_mv | AT durusoyserhat theeffectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis AT onerkerim theeffectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis AT ozeralaattin theeffectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis AT sevinchuseyinfatih theeffectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis AT durusoyserhat effectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis AT onerkerim effectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis AT ozeralaattin effectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis AT sevinchuseyinfatih effectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis |