The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis

OBJECTIVES: This study aims to investigate the effects of the angles created by the Kirschner wires (K-wires), which are applied in the percutaneous fixation of supracondylar humerus fractures with cross K-wire, with the fracture line on fracture stabilization. PATIENTS AND METHODS: The study was co...

Descripción completa

Detalles Bibliográficos
Autores principales: Durusoy, Serhat, Öner, Kerim, Özer, Alaattin, Sevinç, Hüseyin Fatih
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bayçınar Medical Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8073442/
https://www.ncbi.nlm.nih.gov/pubmed/33463421
http://dx.doi.org/10.5606/ehc.2021.77279
_version_ 1783684131231629312
author Durusoy, Serhat
Öner, Kerim
Özer, Alaattin
Sevinç, Hüseyin Fatih
author_facet Durusoy, Serhat
Öner, Kerim
Özer, Alaattin
Sevinç, Hüseyin Fatih
author_sort Durusoy, Serhat
collection PubMed
description OBJECTIVES: This study aims to investigate the effects of the angles created by the Kirschner wires (K-wires), which are applied in the percutaneous fixation of supracondylar humerus fractures with cross K-wire, with the fracture line on fracture stabilization. PATIENTS AND METHODS: The study was conducted on distal humerus fracture models. Medial and lateral K-wires were placed in the fracture models. The angle between the fracture line and the K-wire inserted from medial was represented by alpha (α), while the angle between the fracture line and the K-wires inserted from lateral was represented by beta (β). A combination of various angles (30°, 45°, and 60°) was used in each model, where no two models had the same combination of α and β, resulting in nine different wire configurations. The simulation program was used to simulate the effects of forces, which were applied on rotation, flexion and extension directions, on these models. We measured and compared the stress on the wires and the displacement of fractures under different force configurations. RESULTS: When the force was applied in the counterclockwise direction, the stresses were 58 megaPascal (MPa) on medial K-wire, 24 MPa on lower lateral K-wire, and 45 MPa on upper lateral K-wire in (45°, 45°) wire configuration. When the force was applied in the clockwise direction, the stresses were 57 MPa on medial K-wire, 23 MPa on lower lateral K-wire, and 45 MPa on upper lateral K-wire in (45°, 45°) wire configuration. In all models, the increased α and β angles were translated into the decreased stress on K-wires at the fracture level and decreased displacement under rotational deforming forces. Despite having generally lower fracture displacement, the increased α and β angles led to variable changes in the stress on K-wires against flexion and extension forces. CONCLUSION: In supracondylar humerus fractures, increasing the insertion angle of both medial and lateral K-wires augments stabilization and reduces displacement, particularly against rotational deforming forces.
format Online
Article
Text
id pubmed-8073442
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Bayçınar Medical Publishing
record_format MEDLINE/PubMed
spelling pubmed-80734422021-04-26 The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis Durusoy, Serhat Öner, Kerim Özer, Alaattin Sevinç, Hüseyin Fatih Jt Dis Relat Surg Original Article OBJECTIVES: This study aims to investigate the effects of the angles created by the Kirschner wires (K-wires), which are applied in the percutaneous fixation of supracondylar humerus fractures with cross K-wire, with the fracture line on fracture stabilization. PATIENTS AND METHODS: The study was conducted on distal humerus fracture models. Medial and lateral K-wires were placed in the fracture models. The angle between the fracture line and the K-wire inserted from medial was represented by alpha (α), while the angle between the fracture line and the K-wires inserted from lateral was represented by beta (β). A combination of various angles (30°, 45°, and 60°) was used in each model, where no two models had the same combination of α and β, resulting in nine different wire configurations. The simulation program was used to simulate the effects of forces, which were applied on rotation, flexion and extension directions, on these models. We measured and compared the stress on the wires and the displacement of fractures under different force configurations. RESULTS: When the force was applied in the counterclockwise direction, the stresses were 58 megaPascal (MPa) on medial K-wire, 24 MPa on lower lateral K-wire, and 45 MPa on upper lateral K-wire in (45°, 45°) wire configuration. When the force was applied in the clockwise direction, the stresses were 57 MPa on medial K-wire, 23 MPa on lower lateral K-wire, and 45 MPa on upper lateral K-wire in (45°, 45°) wire configuration. In all models, the increased α and β angles were translated into the decreased stress on K-wires at the fracture level and decreased displacement under rotational deforming forces. Despite having generally lower fracture displacement, the increased α and β angles led to variable changes in the stress on K-wires against flexion and extension forces. CONCLUSION: In supracondylar humerus fractures, increasing the insertion angle of both medial and lateral K-wires augments stabilization and reduces displacement, particularly against rotational deforming forces. Bayçınar Medical Publishing 2021-01-06 /pmc/articles/PMC8073442/ /pubmed/33463421 http://dx.doi.org/10.5606/ehc.2021.77279 Text en Copyright © 2021, Turkish Joint Diseases Foundation https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Article
Durusoy, Serhat
Öner, Kerim
Özer, Alaattin
Sevinç, Hüseyin Fatih
The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis
title The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis
title_full The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis
title_fullStr The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis
title_full_unstemmed The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis
title_short The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis
title_sort effect of the angle between fracture line and kirschner wires on stability in supracondylar humerus fractures treated with kirschner wire fixation: a finite element analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8073442/
https://www.ncbi.nlm.nih.gov/pubmed/33463421
http://dx.doi.org/10.5606/ehc.2021.77279
work_keys_str_mv AT durusoyserhat theeffectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis
AT onerkerim theeffectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis
AT ozeralaattin theeffectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis
AT sevinchuseyinfatih theeffectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis
AT durusoyserhat effectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis
AT onerkerim effectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis
AT ozeralaattin effectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis
AT sevinchuseyinfatih effectoftheanglebetweenfracturelineandkirschnerwiresonstabilityinsupracondylarhumerusfracturestreatedwithkirschnerwirefixationafiniteelementanalysis