Cargando…

Facial nerve regeneration using silicone conduits filled with ammonia-functionalized graphene oxide and frankincense-embedded hydrogel

BACKGROUND: Silicone tube (ST) conduits have been accepted as a therapeutic alternative to direct nerve suturing in the treatment of nerve injuries; however, the search for optimal adjuncts to maximize the outcomes is still ongoing. Frankincense (Fr) and graphene oxide (GO) have both been cited as n...

Descripción completa

Detalles Bibliográficos
Autores principales: Aghajanian, Sepehr, Taghi Doulabi, Aliasghar, Akhbari, Masoume, Shams, Alireza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8073952/
https://www.ncbi.nlm.nih.gov/pubmed/33902759
http://dx.doi.org/10.1186/s41232-021-00162-x
_version_ 1783684247396024320
author Aghajanian, Sepehr
Taghi Doulabi, Aliasghar
Akhbari, Masoume
Shams, Alireza
author_facet Aghajanian, Sepehr
Taghi Doulabi, Aliasghar
Akhbari, Masoume
Shams, Alireza
author_sort Aghajanian, Sepehr
collection PubMed
description BACKGROUND: Silicone tube (ST) conduits have been accepted as a therapeutic alternative to direct nerve suturing in the treatment of nerve injuries; however, the search for optimal adjuncts to maximize the outcomes is still ongoing. Frankincense (Fr) and graphene oxide (GO) have both been cited as neuroregenerative compounds in the literature. This study assesses the efficacy of these materials using a ST conduit in a rat facial nerve motor neuron axotomy model, distal to the stylomastoid foramen. METHODS: Ammonia-functionalized graphene oxide (NH2-GO) and/or Fr extract were embedded in a collagen-chitosan hydrogel and were injected inside a ST. The ST was inserted in the gap between the axotomized nerve stumps. Return of function in eye closure, blinking reflex, and vibrissae movements were assessed and compared to control groups through 30 days following axotomy. To assess the histological properties of regenerated nerves, biopsies were harvested distal to the axotomy site and were visualized through light and fluorescence microscopy using LFB and anti-MBP marker, respectively. RESULTS: There was no significant difference in behavioral test results between groups. Histological analysis of the nerve sections revealed increased number of regenerating axons and mean axon diameter in NH2-GO group and decreased myelin surface area in Fr group. Using both NH2-GO and Fr resulted in increased number of regenerated axons and myelin thickness compared to the hydrogel group. CONCLUSIONS: The findings suggest a synergistic effect of the substances above in axon regrowth, notably in myelin regeneration, where Fr supposedly decreases myelin synthesis.
format Online
Article
Text
id pubmed-8073952
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-80739522021-04-29 Facial nerve regeneration using silicone conduits filled with ammonia-functionalized graphene oxide and frankincense-embedded hydrogel Aghajanian, Sepehr Taghi Doulabi, Aliasghar Akhbari, Masoume Shams, Alireza Inflamm Regen Research Article BACKGROUND: Silicone tube (ST) conduits have been accepted as a therapeutic alternative to direct nerve suturing in the treatment of nerve injuries; however, the search for optimal adjuncts to maximize the outcomes is still ongoing. Frankincense (Fr) and graphene oxide (GO) have both been cited as neuroregenerative compounds in the literature. This study assesses the efficacy of these materials using a ST conduit in a rat facial nerve motor neuron axotomy model, distal to the stylomastoid foramen. METHODS: Ammonia-functionalized graphene oxide (NH2-GO) and/or Fr extract were embedded in a collagen-chitosan hydrogel and were injected inside a ST. The ST was inserted in the gap between the axotomized nerve stumps. Return of function in eye closure, blinking reflex, and vibrissae movements were assessed and compared to control groups through 30 days following axotomy. To assess the histological properties of regenerated nerves, biopsies were harvested distal to the axotomy site and were visualized through light and fluorescence microscopy using LFB and anti-MBP marker, respectively. RESULTS: There was no significant difference in behavioral test results between groups. Histological analysis of the nerve sections revealed increased number of regenerating axons and mean axon diameter in NH2-GO group and decreased myelin surface area in Fr group. Using both NH2-GO and Fr resulted in increased number of regenerated axons and myelin thickness compared to the hydrogel group. CONCLUSIONS: The findings suggest a synergistic effect of the substances above in axon regrowth, notably in myelin regeneration, where Fr supposedly decreases myelin synthesis. BioMed Central 2021-04-26 /pmc/articles/PMC8073952/ /pubmed/33902759 http://dx.doi.org/10.1186/s41232-021-00162-x Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Article
Aghajanian, Sepehr
Taghi Doulabi, Aliasghar
Akhbari, Masoume
Shams, Alireza
Facial nerve regeneration using silicone conduits filled with ammonia-functionalized graphene oxide and frankincense-embedded hydrogel
title Facial nerve regeneration using silicone conduits filled with ammonia-functionalized graphene oxide and frankincense-embedded hydrogel
title_full Facial nerve regeneration using silicone conduits filled with ammonia-functionalized graphene oxide and frankincense-embedded hydrogel
title_fullStr Facial nerve regeneration using silicone conduits filled with ammonia-functionalized graphene oxide and frankincense-embedded hydrogel
title_full_unstemmed Facial nerve regeneration using silicone conduits filled with ammonia-functionalized graphene oxide and frankincense-embedded hydrogel
title_short Facial nerve regeneration using silicone conduits filled with ammonia-functionalized graphene oxide and frankincense-embedded hydrogel
title_sort facial nerve regeneration using silicone conduits filled with ammonia-functionalized graphene oxide and frankincense-embedded hydrogel
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8073952/
https://www.ncbi.nlm.nih.gov/pubmed/33902759
http://dx.doi.org/10.1186/s41232-021-00162-x
work_keys_str_mv AT aghajaniansepehr facialnerveregenerationusingsiliconeconduitsfilledwithammoniafunctionalizedgrapheneoxideandfrankincenseembeddedhydrogel
AT taghidoulabialiasghar facialnerveregenerationusingsiliconeconduitsfilledwithammoniafunctionalizedgrapheneoxideandfrankincenseembeddedhydrogel
AT akhbarimasoume facialnerveregenerationusingsiliconeconduitsfilledwithammoniafunctionalizedgrapheneoxideandfrankincenseembeddedhydrogel
AT shamsalireza facialnerveregenerationusingsiliconeconduitsfilledwithammoniafunctionalizedgrapheneoxideandfrankincenseembeddedhydrogel