Cargando…
A Modified Flexor Tendon Suture Technique Combining Kessler and Loop Lock Flexor Tendon Sutures
OBJECTIVES: In the present study, a novel single knot tenorrhaphy was developed by combining the modified Kessler flexor tendon suture (MK) with the loop lock technique. METHODS: A total of 48 porcine flexor digitorum profundus tendons were collected and randomly divided into six groups. The tendons...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Faculdade de Medicina / USP
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8075114/ https://www.ncbi.nlm.nih.gov/pubmed/33978072 http://dx.doi.org/10.6061/clinics/2021/e2358 |
_version_ | 1783684482278096896 |
---|---|
author | Yang, Wenfeng Li, Jvtao Su, Yuewen Liang, Wu Ren, Yuanfei Dong, Yvjin Shang, Yaohua Zhong, Sheng Xu, Lianchun Zhang, Tiehui |
author_facet | Yang, Wenfeng Li, Jvtao Su, Yuewen Liang, Wu Ren, Yuanfei Dong, Yvjin Shang, Yaohua Zhong, Sheng Xu, Lianchun Zhang, Tiehui |
author_sort | Yang, Wenfeng |
collection | PubMed |
description | OBJECTIVES: In the present study, a novel single knot tenorrhaphy was developed by combining the modified Kessler flexor tendon suture (MK) with the loop lock technique. METHODS: A total of 48 porcine flexor digitorum profundus tendons were collected and randomly divided into six groups. The tendons were transversely cut and then repaired using six different techniques, the MK method, double knot Kessler-loop lock flexor tendon suture (DK), and single knot Kessler-loop lock flexor tendon suture (SK), each in combination with the epitendinous suture (P), and the same three techniques without P. Furthermore, by performing the load-to-failure tests, the biomechanical properties and the time taken to complete a repair, for each tenorrhaphy, were assessed. RESULTS: Compared to the MK+P method, DK+P was more improved, thereby enhancing the ultimate tensile strength. The SK+P method, which required fewer knots than DK+P, was easier to perform. Moreover, the SK+P repair increased the force at a 2-mm gap formation, while requiring lesser knots than DK+P. CONCLUSION: As opposed to the traditional MK+P method, the SK+P method was improved and exhibited better biomechanical properties, which may facilitate early mobilization after the repair. |
format | Online Article Text |
id | pubmed-8075114 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Faculdade de Medicina / USP |
record_format | MEDLINE/PubMed |
spelling | pubmed-80751142021-04-30 A Modified Flexor Tendon Suture Technique Combining Kessler and Loop Lock Flexor Tendon Sutures Yang, Wenfeng Li, Jvtao Su, Yuewen Liang, Wu Ren, Yuanfei Dong, Yvjin Shang, Yaohua Zhong, Sheng Xu, Lianchun Zhang, Tiehui Clinics (Sao Paulo) Original Article OBJECTIVES: In the present study, a novel single knot tenorrhaphy was developed by combining the modified Kessler flexor tendon suture (MK) with the loop lock technique. METHODS: A total of 48 porcine flexor digitorum profundus tendons were collected and randomly divided into six groups. The tendons were transversely cut and then repaired using six different techniques, the MK method, double knot Kessler-loop lock flexor tendon suture (DK), and single knot Kessler-loop lock flexor tendon suture (SK), each in combination with the epitendinous suture (P), and the same three techniques without P. Furthermore, by performing the load-to-failure tests, the biomechanical properties and the time taken to complete a repair, for each tenorrhaphy, were assessed. RESULTS: Compared to the MK+P method, DK+P was more improved, thereby enhancing the ultimate tensile strength. The SK+P method, which required fewer knots than DK+P, was easier to perform. Moreover, the SK+P repair increased the force at a 2-mm gap formation, while requiring lesser knots than DK+P. CONCLUSION: As opposed to the traditional MK+P method, the SK+P method was improved and exhibited better biomechanical properties, which may facilitate early mobilization after the repair. Faculdade de Medicina / USP 2021-04-26 2021 /pmc/articles/PMC8075114/ /pubmed/33978072 http://dx.doi.org/10.6061/clinics/2021/e2358 Text en Copyright © 2021 CLINICS https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons License (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ) which permits unrestricted use, distribution, and reproduction in any medium or format, provided the original work is properly cited. |
spellingShingle | Original Article Yang, Wenfeng Li, Jvtao Su, Yuewen Liang, Wu Ren, Yuanfei Dong, Yvjin Shang, Yaohua Zhong, Sheng Xu, Lianchun Zhang, Tiehui A Modified Flexor Tendon Suture Technique Combining Kessler and Loop Lock Flexor Tendon Sutures |
title | A Modified Flexor Tendon Suture Technique Combining Kessler and Loop Lock Flexor Tendon Sutures |
title_full | A Modified Flexor Tendon Suture Technique Combining Kessler and Loop Lock Flexor Tendon Sutures |
title_fullStr | A Modified Flexor Tendon Suture Technique Combining Kessler and Loop Lock Flexor Tendon Sutures |
title_full_unstemmed | A Modified Flexor Tendon Suture Technique Combining Kessler and Loop Lock Flexor Tendon Sutures |
title_short | A Modified Flexor Tendon Suture Technique Combining Kessler and Loop Lock Flexor Tendon Sutures |
title_sort | modified flexor tendon suture technique combining kessler and loop lock flexor tendon sutures |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8075114/ https://www.ncbi.nlm.nih.gov/pubmed/33978072 http://dx.doi.org/10.6061/clinics/2021/e2358 |
work_keys_str_mv | AT yangwenfeng amodifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT lijvtao amodifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT suyuewen amodifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT liangwu amodifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT renyuanfei amodifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT dongyvjin amodifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT shangyaohua amodifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT zhongsheng amodifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT xulianchun amodifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT zhangtiehui amodifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT yangwenfeng modifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT lijvtao modifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT suyuewen modifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT liangwu modifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT renyuanfei modifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT dongyvjin modifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT shangyaohua modifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT zhongsheng modifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT xulianchun modifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures AT zhangtiehui modifiedflexortendonsuturetechniquecombiningkesslerandlooplockflexortendonsutures |