Cargando…
A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection
OBJECTIVE: This study is the largest clinical study of noninvasive Abdominal wall tension (AWT) measurement with a tensiometer to date. It also initially applies a polynomial regression equation to analyze the correlation between AWT measurement and intravesical pressure (IVP) measurement and remark...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8075309/ https://www.ncbi.nlm.nih.gov/pubmed/33911903 http://dx.doi.org/10.2147/MDER.S291407 |
_version_ | 1783684516855939072 |
---|---|
author | Tang, Hao Liu, Dong Guo, Yong Zhang, Huayu Li, Yang Peng, Xiaoyu Wang, Yaoli Jiang, Dongpo Zhang, Lianyang Wang, Zhengguo |
author_facet | Tang, Hao Liu, Dong Guo, Yong Zhang, Huayu Li, Yang Peng, Xiaoyu Wang, Yaoli Jiang, Dongpo Zhang, Lianyang Wang, Zhengguo |
author_sort | Tang, Hao |
collection | PubMed |
description | OBJECTIVE: This study is the largest clinical study of noninvasive Abdominal wall tension (AWT) measurement with a tensiometer to date. It also initially applies a polynomial regression equation to analyze the correlation between AWT measurement and intravesical pressure (IVP) measurement and remarkably finds interesting changes between different IVP intervals and AWT. METHODS: Critically ill patients who were treated in the intensive care unit (ICU) of Daping Hospital, Army Medical University, from August 30, 2018, to June 30, 2020, and met the inclusion criteria were prospectively included in this study. The patients were divided into an intra-abdominal hypertension group and a non-intra-abdominal hypertension group and an abdominal infection group and no abdominal infection group. AWT and IVP were measured at 9 points on the abdominal wall on the first day after admission to the ICU. The correlations between AWTs and IVP were analyzed, and the role of AWT in the diagnosis of complications of abdominal infection and the prediction of adverse prognosis were analyzed. RESULTS: A total of 127 patients were included. The average AWT and IVP were 2.77±0.38 N/mm and 12.31±7.01 mmHg, respectively, on the first day of admission. There was a positive correlation between AWT and IVP (correlation coefficient r = 0.706, p < 0.05). The polynomial regression model was AWT= -1.616×10(−3) IVP(2) +8.323×10(−2) IVP+2.094. The cutoff value of the sensitivity and specificity of AWT for the diagnosis of abdominal infection was 2.57 N/mm. Furthermore, AWT = 2.57 N/mm had the best diagnostic efficiency, which was better than that of IAH and lactate. CONCLUSION: There was a correlation between AWT and IVP. AWT measurement was helpful in the diagnosis of IAH and abdominal infection complications and can therefore serve as a new method for the clinical diagnosis of IVP and abdominal infection. |
format | Online Article Text |
id | pubmed-8075309 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-80753092021-04-27 A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection Tang, Hao Liu, Dong Guo, Yong Zhang, Huayu Li, Yang Peng, Xiaoyu Wang, Yaoli Jiang, Dongpo Zhang, Lianyang Wang, Zhengguo Med Devices (Auckl) Original Research OBJECTIVE: This study is the largest clinical study of noninvasive Abdominal wall tension (AWT) measurement with a tensiometer to date. It also initially applies a polynomial regression equation to analyze the correlation between AWT measurement and intravesical pressure (IVP) measurement and remarkably finds interesting changes between different IVP intervals and AWT. METHODS: Critically ill patients who were treated in the intensive care unit (ICU) of Daping Hospital, Army Medical University, from August 30, 2018, to June 30, 2020, and met the inclusion criteria were prospectively included in this study. The patients were divided into an intra-abdominal hypertension group and a non-intra-abdominal hypertension group and an abdominal infection group and no abdominal infection group. AWT and IVP were measured at 9 points on the abdominal wall on the first day after admission to the ICU. The correlations between AWTs and IVP were analyzed, and the role of AWT in the diagnosis of complications of abdominal infection and the prediction of adverse prognosis were analyzed. RESULTS: A total of 127 patients were included. The average AWT and IVP were 2.77±0.38 N/mm and 12.31±7.01 mmHg, respectively, on the first day of admission. There was a positive correlation between AWT and IVP (correlation coefficient r = 0.706, p < 0.05). The polynomial regression model was AWT= -1.616×10(−3) IVP(2) +8.323×10(−2) IVP+2.094. The cutoff value of the sensitivity and specificity of AWT for the diagnosis of abdominal infection was 2.57 N/mm. Furthermore, AWT = 2.57 N/mm had the best diagnostic efficiency, which was better than that of IAH and lactate. CONCLUSION: There was a correlation between AWT and IVP. AWT measurement was helpful in the diagnosis of IAH and abdominal infection complications and can therefore serve as a new method for the clinical diagnosis of IVP and abdominal infection. Dove 2021-04-22 /pmc/articles/PMC8075309/ /pubmed/33911903 http://dx.doi.org/10.2147/MDER.S291407 Text en © 2021 Tang et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Tang, Hao Liu, Dong Guo, Yong Zhang, Huayu Li, Yang Peng, Xiaoyu Wang, Yaoli Jiang, Dongpo Zhang, Lianyang Wang, Zhengguo A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection |
title | A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection |
title_full | A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection |
title_fullStr | A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection |
title_full_unstemmed | A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection |
title_short | A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection |
title_sort | new device for measuring abdominal wall tension and its value in screening abdominal infection |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8075309/ https://www.ncbi.nlm.nih.gov/pubmed/33911903 http://dx.doi.org/10.2147/MDER.S291407 |
work_keys_str_mv | AT tanghao anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT liudong anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT guoyong anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT zhanghuayu anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT liyang anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT pengxiaoyu anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT wangyaoli anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT jiangdongpo anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT zhanglianyang anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT wangzhengguo anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT tanghao newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT liudong newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT guoyong newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT zhanghuayu newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT liyang newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT pengxiaoyu newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT wangyaoli newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT jiangdongpo newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT zhanglianyang newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection AT wangzhengguo newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection |