A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection

OBJECTIVE: This study is the largest clinical study of noninvasive Abdominal wall tension (AWT) measurement with a tensiometer to date. It also initially applies a polynomial regression equation to analyze the correlation between AWT measurement and intravesical pressure (IVP) measurement and remark...

Descripción completa

Detalles Bibliográficos
Autores principales: Tang, Hao, Liu, Dong, Guo, Yong, Zhang, Huayu, Li, Yang, Peng, Xiaoyu, Wang, Yaoli, Jiang, Dongpo, Zhang, Lianyang, Wang, Zhengguo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8075309/
https://www.ncbi.nlm.nih.gov/pubmed/33911903
http://dx.doi.org/10.2147/MDER.S291407
_version_ 1783684516855939072
author Tang, Hao
Liu, Dong
Guo, Yong
Zhang, Huayu
Li, Yang
Peng, Xiaoyu
Wang, Yaoli
Jiang, Dongpo
Zhang, Lianyang
Wang, Zhengguo
author_facet Tang, Hao
Liu, Dong
Guo, Yong
Zhang, Huayu
Li, Yang
Peng, Xiaoyu
Wang, Yaoli
Jiang, Dongpo
Zhang, Lianyang
Wang, Zhengguo
author_sort Tang, Hao
collection PubMed
description OBJECTIVE: This study is the largest clinical study of noninvasive Abdominal wall tension (AWT) measurement with a tensiometer to date. It also initially applies a polynomial regression equation to analyze the correlation between AWT measurement and intravesical pressure (IVP) measurement and remarkably finds interesting changes between different IVP intervals and AWT. METHODS: Critically ill patients who were treated in the intensive care unit (ICU) of Daping Hospital, Army Medical University, from August 30, 2018, to June 30, 2020, and met the inclusion criteria were prospectively included in this study. The patients were divided into an intra-abdominal hypertension group and a non-intra-abdominal hypertension group and an abdominal infection group and no abdominal infection group. AWT and IVP were measured at 9 points on the abdominal wall on the first day after admission to the ICU. The correlations between AWTs and IVP were analyzed, and the role of AWT in the diagnosis of complications of abdominal infection and the prediction of adverse prognosis were analyzed. RESULTS: A total of 127 patients were included. The average AWT and IVP were 2.77±0.38 N/mm and 12.31±7.01 mmHg, respectively, on the first day of admission. There was a positive correlation between AWT and IVP (correlation coefficient r = 0.706, p < 0.05). The polynomial regression model was AWT= -1.616×10(−3) IVP(2) +8.323×10(−2) IVP+2.094. The cutoff value of the sensitivity and specificity of AWT for the diagnosis of abdominal infection was 2.57 N/mm. Furthermore, AWT = 2.57 N/mm had the best diagnostic efficiency, which was better than that of IAH and lactate. CONCLUSION: There was a correlation between AWT and IVP. AWT measurement was helpful in the diagnosis of IAH and abdominal infection complications and can therefore serve as a new method for the clinical diagnosis of IVP and abdominal infection.
format Online
Article
Text
id pubmed-8075309
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-80753092021-04-27 A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection Tang, Hao Liu, Dong Guo, Yong Zhang, Huayu Li, Yang Peng, Xiaoyu Wang, Yaoli Jiang, Dongpo Zhang, Lianyang Wang, Zhengguo Med Devices (Auckl) Original Research OBJECTIVE: This study is the largest clinical study of noninvasive Abdominal wall tension (AWT) measurement with a tensiometer to date. It also initially applies a polynomial regression equation to analyze the correlation between AWT measurement and intravesical pressure (IVP) measurement and remarkably finds interesting changes between different IVP intervals and AWT. METHODS: Critically ill patients who were treated in the intensive care unit (ICU) of Daping Hospital, Army Medical University, from August 30, 2018, to June 30, 2020, and met the inclusion criteria were prospectively included in this study. The patients were divided into an intra-abdominal hypertension group and a non-intra-abdominal hypertension group and an abdominal infection group and no abdominal infection group. AWT and IVP were measured at 9 points on the abdominal wall on the first day after admission to the ICU. The correlations between AWTs and IVP were analyzed, and the role of AWT in the diagnosis of complications of abdominal infection and the prediction of adverse prognosis were analyzed. RESULTS: A total of 127 patients were included. The average AWT and IVP were 2.77±0.38 N/mm and 12.31±7.01 mmHg, respectively, on the first day of admission. There was a positive correlation between AWT and IVP (correlation coefficient r = 0.706, p < 0.05). The polynomial regression model was AWT= -1.616×10(−3) IVP(2) +8.323×10(−2) IVP+2.094. The cutoff value of the sensitivity and specificity of AWT for the diagnosis of abdominal infection was 2.57 N/mm. Furthermore, AWT = 2.57 N/mm had the best diagnostic efficiency, which was better than that of IAH and lactate. CONCLUSION: There was a correlation between AWT and IVP. AWT measurement was helpful in the diagnosis of IAH and abdominal infection complications and can therefore serve as a new method for the clinical diagnosis of IVP and abdominal infection. Dove 2021-04-22 /pmc/articles/PMC8075309/ /pubmed/33911903 http://dx.doi.org/10.2147/MDER.S291407 Text en © 2021 Tang et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Tang, Hao
Liu, Dong
Guo, Yong
Zhang, Huayu
Li, Yang
Peng, Xiaoyu
Wang, Yaoli
Jiang, Dongpo
Zhang, Lianyang
Wang, Zhengguo
A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection
title A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection
title_full A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection
title_fullStr A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection
title_full_unstemmed A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection
title_short A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection
title_sort new device for measuring abdominal wall tension and its value in screening abdominal infection
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8075309/
https://www.ncbi.nlm.nih.gov/pubmed/33911903
http://dx.doi.org/10.2147/MDER.S291407
work_keys_str_mv AT tanghao anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT liudong anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT guoyong anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT zhanghuayu anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT liyang anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT pengxiaoyu anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT wangyaoli anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT jiangdongpo anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT zhanglianyang anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT wangzhengguo anewdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT tanghao newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT liudong newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT guoyong newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT zhanghuayu newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT liyang newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT pengxiaoyu newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT wangyaoli newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT jiangdongpo newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT zhanglianyang newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection
AT wangzhengguo newdeviceformeasuringabdominalwalltensionanditsvalueinscreeningabdominalinfection