Cargando…
Three-Dimensional Printing of Congenital Heart Disease Models for Cardiac Surgery Simulation: Evaluation of Surgical Skill Improvement among Inexperienced Cardiothoracic Surgeons
OBJECTIVE: To evaluate the impact of surgical simulation training using a three-dimensional (3D)-printed model of tetralogy of Fallot (TOF) on surgical skill development. MATERIALS AND METHODS: A life-size congenital heart disease model was printed using a Stratasys Object500 Connex2 printer from pr...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8076818/ https://www.ncbi.nlm.nih.gov/pubmed/33543844 http://dx.doi.org/10.3348/kjr.2020.0682 |
_version_ | 1783684764561047552 |
---|---|
author | Nam, Ju Gang Lee, Whal Jeong, Baren Park, Eun-Ah Lim, Ji Yeon Kwak, Yujin Lim, Hong-Gook |
author_facet | Nam, Ju Gang Lee, Whal Jeong, Baren Park, Eun-Ah Lim, Ji Yeon Kwak, Yujin Lim, Hong-Gook |
author_sort | Nam, Ju Gang |
collection | PubMed |
description | OBJECTIVE: To evaluate the impact of surgical simulation training using a three-dimensional (3D)-printed model of tetralogy of Fallot (TOF) on surgical skill development. MATERIALS AND METHODS: A life-size congenital heart disease model was printed using a Stratasys Object500 Connex2 printer from preoperative electrocardiography-gated CT scans of a 6-month-old patient with TOF with complex pulmonary stenosis. Eleven cardiothoracic surgeons independently evaluated the suitability of four 3D-printed models using composite Tango 27, 40, 50, and 60 in terms of palpation, resistance, extensibility, gap, cut-through ability, and reusability of. Among these, Tango 27 was selected as the final model. Six attendees (two junior cardiothoracic surgery residents, two senior residents, and two clinical fellows) independently performed simulation surgeries three times each. Surgical proficiency was evaluated by an experienced cardiothoracic surgeon on a 1–10 scale for each of the 10 surgical procedures. The times required for each surgical procedure were also measured. RESULTS: In the simulation surgeries, six surgeons required a median of 34.4 (range 32.5–43.5) and 21.4 (17.9–192.7) minutes to apply the ventricular septal defect (VSD) and right ventricular outflow tract (RVOT) patches, respectively, on their first simulation surgery. These times had significantly reduced to 17.3 (16.2–29.5) and 13.6 (10.3–30.0) minutes, respectively, in the third simulation surgery (p = 0.03 and p = 0.01, respectively). The decreases in the median patch appliance time among the six surgeons were 16.2 (range 13.6–17.7) and 8.0 (1.8–170.3) minutes for the VSD and RVOT patches, respectively. Summing the scores for the 10 procedures showed that the attendees scored an average of 28.58 ± 7.89 points on the first simulation surgery and improved their average score to 67.33 ± 15.10 on the third simulation surgery (p = 0.008). CONCLUSION: Inexperienced cardiothoracic surgeons improved their performance in terms of surgical proficiency and operation time during the experience of three simulation surgeries using a 3D-printed TOF model using Tango 27 composite. |
format | Online Article Text |
id | pubmed-8076818 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-80768182021-05-06 Three-Dimensional Printing of Congenital Heart Disease Models for Cardiac Surgery Simulation: Evaluation of Surgical Skill Improvement among Inexperienced Cardiothoracic Surgeons Nam, Ju Gang Lee, Whal Jeong, Baren Park, Eun-Ah Lim, Ji Yeon Kwak, Yujin Lim, Hong-Gook Korean J Radiol Cardiovascular Imaging OBJECTIVE: To evaluate the impact of surgical simulation training using a three-dimensional (3D)-printed model of tetralogy of Fallot (TOF) on surgical skill development. MATERIALS AND METHODS: A life-size congenital heart disease model was printed using a Stratasys Object500 Connex2 printer from preoperative electrocardiography-gated CT scans of a 6-month-old patient with TOF with complex pulmonary stenosis. Eleven cardiothoracic surgeons independently evaluated the suitability of four 3D-printed models using composite Tango 27, 40, 50, and 60 in terms of palpation, resistance, extensibility, gap, cut-through ability, and reusability of. Among these, Tango 27 was selected as the final model. Six attendees (two junior cardiothoracic surgery residents, two senior residents, and two clinical fellows) independently performed simulation surgeries three times each. Surgical proficiency was evaluated by an experienced cardiothoracic surgeon on a 1–10 scale for each of the 10 surgical procedures. The times required for each surgical procedure were also measured. RESULTS: In the simulation surgeries, six surgeons required a median of 34.4 (range 32.5–43.5) and 21.4 (17.9–192.7) minutes to apply the ventricular septal defect (VSD) and right ventricular outflow tract (RVOT) patches, respectively, on their first simulation surgery. These times had significantly reduced to 17.3 (16.2–29.5) and 13.6 (10.3–30.0) minutes, respectively, in the third simulation surgery (p = 0.03 and p = 0.01, respectively). The decreases in the median patch appliance time among the six surgeons were 16.2 (range 13.6–17.7) and 8.0 (1.8–170.3) minutes for the VSD and RVOT patches, respectively. Summing the scores for the 10 procedures showed that the attendees scored an average of 28.58 ± 7.89 points on the first simulation surgery and improved their average score to 67.33 ± 15.10 on the third simulation surgery (p = 0.008). CONCLUSION: Inexperienced cardiothoracic surgeons improved their performance in terms of surgical proficiency and operation time during the experience of three simulation surgeries using a 3D-printed TOF model using Tango 27 composite. The Korean Society of Radiology 2021-05 2020-12-21 /pmc/articles/PMC8076818/ /pubmed/33543844 http://dx.doi.org/10.3348/kjr.2020.0682 Text en Copyright © 2021 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Cardiovascular Imaging Nam, Ju Gang Lee, Whal Jeong, Baren Park, Eun-Ah Lim, Ji Yeon Kwak, Yujin Lim, Hong-Gook Three-Dimensional Printing of Congenital Heart Disease Models for Cardiac Surgery Simulation: Evaluation of Surgical Skill Improvement among Inexperienced Cardiothoracic Surgeons |
title | Three-Dimensional Printing of Congenital Heart Disease Models for Cardiac Surgery Simulation: Evaluation of Surgical Skill Improvement among Inexperienced Cardiothoracic Surgeons |
title_full | Three-Dimensional Printing of Congenital Heart Disease Models for Cardiac Surgery Simulation: Evaluation of Surgical Skill Improvement among Inexperienced Cardiothoracic Surgeons |
title_fullStr | Three-Dimensional Printing of Congenital Heart Disease Models for Cardiac Surgery Simulation: Evaluation of Surgical Skill Improvement among Inexperienced Cardiothoracic Surgeons |
title_full_unstemmed | Three-Dimensional Printing of Congenital Heart Disease Models for Cardiac Surgery Simulation: Evaluation of Surgical Skill Improvement among Inexperienced Cardiothoracic Surgeons |
title_short | Three-Dimensional Printing of Congenital Heart Disease Models for Cardiac Surgery Simulation: Evaluation of Surgical Skill Improvement among Inexperienced Cardiothoracic Surgeons |
title_sort | three-dimensional printing of congenital heart disease models for cardiac surgery simulation: evaluation of surgical skill improvement among inexperienced cardiothoracic surgeons |
topic | Cardiovascular Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8076818/ https://www.ncbi.nlm.nih.gov/pubmed/33543844 http://dx.doi.org/10.3348/kjr.2020.0682 |
work_keys_str_mv | AT namjugang threedimensionalprintingofcongenitalheartdiseasemodelsforcardiacsurgerysimulationevaluationofsurgicalskillimprovementamonginexperiencedcardiothoracicsurgeons AT leewhal threedimensionalprintingofcongenitalheartdiseasemodelsforcardiacsurgerysimulationevaluationofsurgicalskillimprovementamonginexperiencedcardiothoracicsurgeons AT jeongbaren threedimensionalprintingofcongenitalheartdiseasemodelsforcardiacsurgerysimulationevaluationofsurgicalskillimprovementamonginexperiencedcardiothoracicsurgeons AT parkeunah threedimensionalprintingofcongenitalheartdiseasemodelsforcardiacsurgerysimulationevaluationofsurgicalskillimprovementamonginexperiencedcardiothoracicsurgeons AT limjiyeon threedimensionalprintingofcongenitalheartdiseasemodelsforcardiacsurgerysimulationevaluationofsurgicalskillimprovementamonginexperiencedcardiothoracicsurgeons AT kwakyujin threedimensionalprintingofcongenitalheartdiseasemodelsforcardiacsurgerysimulationevaluationofsurgicalskillimprovementamonginexperiencedcardiothoracicsurgeons AT limhonggook threedimensionalprintingofcongenitalheartdiseasemodelsforcardiacsurgerysimulationevaluationofsurgicalskillimprovementamonginexperiencedcardiothoracicsurgeons |