Cargando…

Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model

OBJECTIVE: To evaluate the signal intensity of the periosteum using ultrashort echo time pulse sequence with three-dimensional cone trajectory (3D UTE) with or without fat suppression (FS) to distinguish from artifacts in porcine tibias. MATERIALS AND METHODS: The periosteum and overlying soft tissu...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Dae Joong, Hwang, Kun, Kim, Hun, Cha, Jang Gyu, Jang, Hyungseok, Park, Ju-Yong, Kim, Yeo Ju
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8076835/
https://www.ncbi.nlm.nih.gov/pubmed/33660460
http://dx.doi.org/10.3348/kjr.2020.0640
_version_ 1783684768517324800
author Kim, Dae Joong
Hwang, Kun
Kim, Hun
Cha, Jang Gyu
Jang, Hyungseok
Park, Ju-Yong
Kim, Yeo Ju
author_facet Kim, Dae Joong
Hwang, Kun
Kim, Hun
Cha, Jang Gyu
Jang, Hyungseok
Park, Ju-Yong
Kim, Yeo Ju
author_sort Kim, Dae Joong
collection PubMed
description OBJECTIVE: To evaluate the signal intensity of the periosteum using ultrashort echo time pulse sequence with three-dimensional cone trajectory (3D UTE) with or without fat suppression (FS) to distinguish from artifacts in porcine tibias. MATERIALS AND METHODS: The periosteum and overlying soft tissue of three porcine lower legs were partially peeled away from the tibial cortex. Another porcine tibia was prepared as three segments: with an intact periosteum outer and inner layer, with an intact periosteum inner layer, and without periosteum. Axial T1 weighted sequence (T1 WI) and 3D UTE (FS) were performed. Another porcine tibia without periosteum was prepared and subjected to 3D UTE (FS) and T1 WI twice, with positional changes. Two radiologists analyzed images to reach a consensus. RESULTS: The three periosteal tissues that were partially peeled away from the cortex showed a high signal in 3D UTE (FS) and low signal on T1 WI. 3D UTE (FS) showed a high signal around the cortical surface with an intact outer and inner periosteum, and subtle high signals, mainly around the upper cortical surfaces with the inner layer of the periosteum and without periosteum. T1 WI showed no signal around the cortical surfaces, regardless of the periosteum state. The porcine tibia without periosteum showed changes in the high signal area around the cortical surface as the position changed in 3D UTE (FS). No signal was detected around the cortical surface in T1 WI, regardless of the position change. CONCLUSION: The periosteum showed a high signal in 3D UTE and 3D UTE FS that overlapped with artifacts around the cortical bone.
format Online
Article
Text
id pubmed-8076835
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-80768352021-05-06 Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model Kim, Dae Joong Hwang, Kun Kim, Hun Cha, Jang Gyu Jang, Hyungseok Park, Ju-Yong Kim, Yeo Ju Korean J Radiol Musculoskeletal Imaging OBJECTIVE: To evaluate the signal intensity of the periosteum using ultrashort echo time pulse sequence with three-dimensional cone trajectory (3D UTE) with or without fat suppression (FS) to distinguish from artifacts in porcine tibias. MATERIALS AND METHODS: The periosteum and overlying soft tissue of three porcine lower legs were partially peeled away from the tibial cortex. Another porcine tibia was prepared as three segments: with an intact periosteum outer and inner layer, with an intact periosteum inner layer, and without periosteum. Axial T1 weighted sequence (T1 WI) and 3D UTE (FS) were performed. Another porcine tibia without periosteum was prepared and subjected to 3D UTE (FS) and T1 WI twice, with positional changes. Two radiologists analyzed images to reach a consensus. RESULTS: The three periosteal tissues that were partially peeled away from the cortex showed a high signal in 3D UTE (FS) and low signal on T1 WI. 3D UTE (FS) showed a high signal around the cortical surface with an intact outer and inner periosteum, and subtle high signals, mainly around the upper cortical surfaces with the inner layer of the periosteum and without periosteum. T1 WI showed no signal around the cortical surfaces, regardless of the periosteum state. The porcine tibia without periosteum showed changes in the high signal area around the cortical surface as the position changed in 3D UTE (FS). No signal was detected around the cortical surface in T1 WI, regardless of the position change. CONCLUSION: The periosteum showed a high signal in 3D UTE and 3D UTE FS that overlapped with artifacts around the cortical bone. The Korean Society of Radiology 2021-05 2021-02-09 /pmc/articles/PMC8076835/ /pubmed/33660460 http://dx.doi.org/10.3348/kjr.2020.0640 Text en Copyright © 2021 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Musculoskeletal Imaging
Kim, Dae Joong
Hwang, Kun
Kim, Hun
Cha, Jang Gyu
Jang, Hyungseok
Park, Ju-Yong
Kim, Yeo Ju
Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model
title Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model
title_full Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model
title_fullStr Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model
title_full_unstemmed Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model
title_short Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model
title_sort depiction of the periosteum using ultrashort echo time pulse sequence with three-dimensional cone trajectory and histologic correlation in a porcine model
topic Musculoskeletal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8076835/
https://www.ncbi.nlm.nih.gov/pubmed/33660460
http://dx.doi.org/10.3348/kjr.2020.0640
work_keys_str_mv AT kimdaejoong depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel
AT hwangkun depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel
AT kimhun depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel
AT chajanggyu depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel
AT janghyungseok depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel
AT parkjuyong depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel
AT kimyeoju depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel