Cargando…
Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model
OBJECTIVE: To evaluate the signal intensity of the periosteum using ultrashort echo time pulse sequence with three-dimensional cone trajectory (3D UTE) with or without fat suppression (FS) to distinguish from artifacts in porcine tibias. MATERIALS AND METHODS: The periosteum and overlying soft tissu...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8076835/ https://www.ncbi.nlm.nih.gov/pubmed/33660460 http://dx.doi.org/10.3348/kjr.2020.0640 |
_version_ | 1783684768517324800 |
---|---|
author | Kim, Dae Joong Hwang, Kun Kim, Hun Cha, Jang Gyu Jang, Hyungseok Park, Ju-Yong Kim, Yeo Ju |
author_facet | Kim, Dae Joong Hwang, Kun Kim, Hun Cha, Jang Gyu Jang, Hyungseok Park, Ju-Yong Kim, Yeo Ju |
author_sort | Kim, Dae Joong |
collection | PubMed |
description | OBJECTIVE: To evaluate the signal intensity of the periosteum using ultrashort echo time pulse sequence with three-dimensional cone trajectory (3D UTE) with or without fat suppression (FS) to distinguish from artifacts in porcine tibias. MATERIALS AND METHODS: The periosteum and overlying soft tissue of three porcine lower legs were partially peeled away from the tibial cortex. Another porcine tibia was prepared as three segments: with an intact periosteum outer and inner layer, with an intact periosteum inner layer, and without periosteum. Axial T1 weighted sequence (T1 WI) and 3D UTE (FS) were performed. Another porcine tibia without periosteum was prepared and subjected to 3D UTE (FS) and T1 WI twice, with positional changes. Two radiologists analyzed images to reach a consensus. RESULTS: The three periosteal tissues that were partially peeled away from the cortex showed a high signal in 3D UTE (FS) and low signal on T1 WI. 3D UTE (FS) showed a high signal around the cortical surface with an intact outer and inner periosteum, and subtle high signals, mainly around the upper cortical surfaces with the inner layer of the periosteum and without periosteum. T1 WI showed no signal around the cortical surfaces, regardless of the periosteum state. The porcine tibia without periosteum showed changes in the high signal area around the cortical surface as the position changed in 3D UTE (FS). No signal was detected around the cortical surface in T1 WI, regardless of the position change. CONCLUSION: The periosteum showed a high signal in 3D UTE and 3D UTE FS that overlapped with artifacts around the cortical bone. |
format | Online Article Text |
id | pubmed-8076835 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-80768352021-05-06 Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model Kim, Dae Joong Hwang, Kun Kim, Hun Cha, Jang Gyu Jang, Hyungseok Park, Ju-Yong Kim, Yeo Ju Korean J Radiol Musculoskeletal Imaging OBJECTIVE: To evaluate the signal intensity of the periosteum using ultrashort echo time pulse sequence with three-dimensional cone trajectory (3D UTE) with or without fat suppression (FS) to distinguish from artifacts in porcine tibias. MATERIALS AND METHODS: The periosteum and overlying soft tissue of three porcine lower legs were partially peeled away from the tibial cortex. Another porcine tibia was prepared as three segments: with an intact periosteum outer and inner layer, with an intact periosteum inner layer, and without periosteum. Axial T1 weighted sequence (T1 WI) and 3D UTE (FS) were performed. Another porcine tibia without periosteum was prepared and subjected to 3D UTE (FS) and T1 WI twice, with positional changes. Two radiologists analyzed images to reach a consensus. RESULTS: The three periosteal tissues that were partially peeled away from the cortex showed a high signal in 3D UTE (FS) and low signal on T1 WI. 3D UTE (FS) showed a high signal around the cortical surface with an intact outer and inner periosteum, and subtle high signals, mainly around the upper cortical surfaces with the inner layer of the periosteum and without periosteum. T1 WI showed no signal around the cortical surfaces, regardless of the periosteum state. The porcine tibia without periosteum showed changes in the high signal area around the cortical surface as the position changed in 3D UTE (FS). No signal was detected around the cortical surface in T1 WI, regardless of the position change. CONCLUSION: The periosteum showed a high signal in 3D UTE and 3D UTE FS that overlapped with artifacts around the cortical bone. The Korean Society of Radiology 2021-05 2021-02-09 /pmc/articles/PMC8076835/ /pubmed/33660460 http://dx.doi.org/10.3348/kjr.2020.0640 Text en Copyright © 2021 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Musculoskeletal Imaging Kim, Dae Joong Hwang, Kun Kim, Hun Cha, Jang Gyu Jang, Hyungseok Park, Ju-Yong Kim, Yeo Ju Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model |
title | Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model |
title_full | Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model |
title_fullStr | Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model |
title_full_unstemmed | Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model |
title_short | Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model |
title_sort | depiction of the periosteum using ultrashort echo time pulse sequence with three-dimensional cone trajectory and histologic correlation in a porcine model |
topic | Musculoskeletal Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8076835/ https://www.ncbi.nlm.nih.gov/pubmed/33660460 http://dx.doi.org/10.3348/kjr.2020.0640 |
work_keys_str_mv | AT kimdaejoong depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel AT hwangkun depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel AT kimhun depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel AT chajanggyu depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel AT janghyungseok depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel AT parkjuyong depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel AT kimyeoju depictionoftheperiosteumusingultrashortechotimepulsesequencewiththreedimensionalconetrajectoryandhistologiccorrelationinaporcinemodel |