Cargando…

Effect of stem position and length on bone-stem constructs after cementless hip arthroplasty: a finite element analysis

AIMS: There are concerns regarding initial stability and early periprosthetic fractures in cementless hip arthroplasty using short stems. This study aimed to investigate stress on the cortical bone around the stem and micromotions between the stem and cortical bone according to femoral stem length a...

Descripción completa

Detalles Bibliográficos
Autores principales: Kwak, Dae-Kyung, Bang, Sun-Hee, Lee, Sung-Jae, Park, Ji-Hun, Yoo, Je-Hyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The British Editorial Society of Bone & Joint Surgery 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8076980/
https://www.ncbi.nlm.nih.gov/pubmed/33820433
http://dx.doi.org/10.1302/2046-3758.104.BJR-2020-0043.R3
_version_ 1783684797935124480
author Kwak, Dae-Kyung
Bang, Sun-Hee
Lee, Sung-Jae
Park, Ji-Hun
Yoo, Je-Hyun
author_facet Kwak, Dae-Kyung
Bang, Sun-Hee
Lee, Sung-Jae
Park, Ji-Hun
Yoo, Je-Hyun
author_sort Kwak, Dae-Kyung
collection PubMed
description AIMS: There are concerns regarding initial stability and early periprosthetic fractures in cementless hip arthroplasty using short stems. This study aimed to investigate stress on the cortical bone around the stem and micromotions between the stem and cortical bone according to femoral stem length and positioning. METHODS: In total, 12 femoral finite element models (FEMs) were constructed and tested in walking and stair-climbing. Femoral stems of three different lengths and two different positions were simulated, assuming press-fit fixation within each FEM. Stress on the cortical bone and micromotions between the stem and bone were measured in each condition. RESULTS: Stress concentration was observed on the medial and lateral interfaces between the cortical bone and stem. With neutral stem insertion, mean stress over a region of interest was greater at the medial than lateral interface regardless of stem length, which increased as the stem shortened. Mean stress increased in the varus-inserted stems compared to the stems inserted neutrally, especially at the lateral interface in contact with the stem tip. The maximum stress was observed at the lateral interface in a varus-inserted short stem. All mean stresses were greater in stair-climbing condition than walking. Each micromotion was also greater in shorter stems and varus-inserted stems, and in stair-climbing condition. CONCLUSION: The stem should be inserted neutrally and stair-climbing movement should be avoided in the early postoperative period, in order to preserve early stability and reduce the possibility of thigh pain, especially when using a shorter stem. Cite this article: Bone Joint Res 2021;10(4):250–258.
format Online
Article
Text
id pubmed-8076980
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The British Editorial Society of Bone & Joint Surgery
record_format MEDLINE/PubMed
spelling pubmed-80769802021-05-04 Effect of stem position and length on bone-stem constructs after cementless hip arthroplasty: a finite element analysis Kwak, Dae-Kyung Bang, Sun-Hee Lee, Sung-Jae Park, Ji-Hun Yoo, Je-Hyun Bone Joint Res Biomechanics AIMS: There are concerns regarding initial stability and early periprosthetic fractures in cementless hip arthroplasty using short stems. This study aimed to investigate stress on the cortical bone around the stem and micromotions between the stem and cortical bone according to femoral stem length and positioning. METHODS: In total, 12 femoral finite element models (FEMs) were constructed and tested in walking and stair-climbing. Femoral stems of three different lengths and two different positions were simulated, assuming press-fit fixation within each FEM. Stress on the cortical bone and micromotions between the stem and bone were measured in each condition. RESULTS: Stress concentration was observed on the medial and lateral interfaces between the cortical bone and stem. With neutral stem insertion, mean stress over a region of interest was greater at the medial than lateral interface regardless of stem length, which increased as the stem shortened. Mean stress increased in the varus-inserted stems compared to the stems inserted neutrally, especially at the lateral interface in contact with the stem tip. The maximum stress was observed at the lateral interface in a varus-inserted short stem. All mean stresses were greater in stair-climbing condition than walking. Each micromotion was also greater in shorter stems and varus-inserted stems, and in stair-climbing condition. CONCLUSION: The stem should be inserted neutrally and stair-climbing movement should be avoided in the early postoperative period, in order to preserve early stability and reduce the possibility of thigh pain, especially when using a shorter stem. Cite this article: Bone Joint Res 2021;10(4):250–258. The British Editorial Society of Bone & Joint Surgery 2021-04-01 /pmc/articles/PMC8076980/ /pubmed/33820433 http://dx.doi.org/10.1302/2046-3758.104.BJR-2020-0043.R3 Text en © 2021 Author(s) et al. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND 4.0) licence, which permits the copying and redistribution of the work only, and provided the original author and source are credited. See https://creativecommons.org/licenses/by-nc-nd/4.0/.
spellingShingle Biomechanics
Kwak, Dae-Kyung
Bang, Sun-Hee
Lee, Sung-Jae
Park, Ji-Hun
Yoo, Je-Hyun
Effect of stem position and length on bone-stem constructs after cementless hip arthroplasty: a finite element analysis
title Effect of stem position and length on bone-stem constructs after cementless hip arthroplasty: a finite element analysis
title_full Effect of stem position and length on bone-stem constructs after cementless hip arthroplasty: a finite element analysis
title_fullStr Effect of stem position and length on bone-stem constructs after cementless hip arthroplasty: a finite element analysis
title_full_unstemmed Effect of stem position and length on bone-stem constructs after cementless hip arthroplasty: a finite element analysis
title_short Effect of stem position and length on bone-stem constructs after cementless hip arthroplasty: a finite element analysis
title_sort effect of stem position and length on bone-stem constructs after cementless hip arthroplasty: a finite element analysis
topic Biomechanics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8076980/
https://www.ncbi.nlm.nih.gov/pubmed/33820433
http://dx.doi.org/10.1302/2046-3758.104.BJR-2020-0043.R3
work_keys_str_mv AT kwakdaekyung effectofstempositionandlengthonbonestemconstructsaftercementlesshiparthroplastyafiniteelementanalysis
AT bangsunhee effectofstempositionandlengthonbonestemconstructsaftercementlesshiparthroplastyafiniteelementanalysis
AT leesungjae effectofstempositionandlengthonbonestemconstructsaftercementlesshiparthroplastyafiniteelementanalysis
AT parkjihun effectofstempositionandlengthonbonestemconstructsaftercementlesshiparthroplastyafiniteelementanalysis
AT yoojehyun effectofstempositionandlengthonbonestemconstructsaftercementlesshiparthroplastyafiniteelementanalysis